Search results for "Specificity."

showing 10 items of 2232 documents

Application of ACC method to synchronous luminiscence: determination of alpha-tocopherol and alpha-tocopheryl acetate in beverages.

2001

A new method based on the Q parameter, that permits the determination of the C(compound A)/C(compound B) ratio without preparing calibration graphs of the two compounds, is proposed. This method has been applied to signals obtained by synchronous luminiscence. Simultaneous determination of alpha-tocopherol and alpha-tocopheryl acetate in beverages using synchronous fluorescence has been carried out. To isolate the compounds from samples, liquid extraction with n-hexane as the organic phase was employed. The presence of interferences was tested using the apparent content curves (ACC) method and the C(alpha-tocopherol)/C(alpha-tocopheryl acetate) ratio was calculated using the Q parameter. Th…

Detection limitChromatographyExtraction (chemistry)Fluorescence spectrometryAnalytical chemistryReproducibility of ResultsAcetatesBiochemistrySensitivity and SpecificityBeverageschemistry.chemical_compoundSpectrometry FluorescencechemistryModels ChemicalLuminescent MeasurementsSolventsHexanesVitamin ETocopheryl acetateTocopherolalpha-TocopherolQuantitative analysis (chemistry)Vitamin E AcetateFresenius' journal of analytical chemistry
researchProduct

Determination of amitraz and its transformation products in pears by ethyl acetate extraction and liquid chromatography-tandem mass spectrometry.

2008

A method has been developed for identification and quantification of the acaricide amitraz and its transformation products, 2,4-dimethylaniline (DMA), 2,4-dimethylformamidine (DMF) and N-2,4-dimethylphenyl-N-methylformamidine (DMPF) in pears. The analytes were extracted using ethyl acetate and anhydrous sodium sulphate. Analysis was performed by liquid chromatography-electrospray tandem mass spectrometry (LC-ESI-MS/MS) in the positive ion mode using a triple quadrupole (QqQ) instrument. Two precursor-product ion transitions were monitored for each compound in the selected reaction monitoring (SRM) mode. The method was validated with pears taken from the orchard before the amitraz treatment …

Detection limitChromatographyMaximum Residue LimitAniline CompoundsToluidinesSulfatesOrganic ChemistrySelected reaction monitoringEthyl acetatePesticide ResiduesReproducibility of ResultsGeneral MedicineAcetatesBiochemistryHigh-performance liquid chromatographySensitivity and SpecificityAnalytical ChemistryTriple quadrupole mass spectrometerPyruschemistry.chemical_compoundchemistryLiquid chromatography–mass spectrometryTandem Mass SpectrometryAmitrazChromatography LiquidJournal of chromatography. A
researchProduct

Liquid Chromatography Quadrupole Time-of-Flight Mass Spectrometry Analysis of Carbosulfan, Carbofuran, 3-Hydroxycarbofuran, and Other Metabolites in …

2007

The potential of liquid chromatography quadrupole time-of-flight mass spectrometry (LC-QqTOF-MS) to identify and confirm carbosulfan and seven of its main metabolites (carbofuran, 3-hydroxycarbofuran, 3-ketocarbofuran, 3-hydroxy-7-phenol carbofuran, 3-keto-7-phenolcarbofuran, 7-phenolcarbofuran, dibutylamine) at trace levels from food is explored for the first time. The analytical method developed consists of pressurized liquid extraction (PLE) and LC-QqTOF-MS in positive ion mode, which attains unequivocal identification and quantification of the studied compounds in food, at levels well below of those of concern (0.05 mg/kg for the sum of carbosulfan, carbofuran, and 3-hydroxycarbofuran).…

Detection limitChromatographyMolecular StructureMetaboliteRepeatabilityButylaminesMass spectrometrySensitivity and SpecificityAnalytical ChemistryDibutylamineCarbofuranchemistry.chemical_compoundchemistrySpectrometry Mass Matrix-Assisted Laser Desorption-IonizationCarbosulfanCarbamatesQuantitative analysis (chemistry)CarbofuranFood AnalysisChromatography LiquidAnalytical Chemistry
researchProduct

Determination ofl-Ascorbic Acid and Total Ascorbic Acid in Vascular and Nonvascular Plants by Capillary Zone Electrophoresis

1998

A capillary zone electrophoresis (CZE) procedure for the determination of l-ascorbic acid (AA) and total ascorbic acid (TAA, as the sum of AA and dehydroascorbic acid) in vascular plants, lichens, bryophytes, and liverworts is described. The samples were frozen in liquid nitrogen and extracted with 2% metaphosphoric acid. To determine AA, an aliquot was directly injected in a fused-silica capillary. The determination of TAA was performed upon its reduction with dl-homocysteine at pH 7. The background electrolyte contained 60 mM sodium chloride, 60 mM sodium dihydrogen phosphate, 1 x 10(-4)% hexadimetrine bromide, and NaOH up to pH 7. The procedure was rapid and highly reproducible; the limi…

Detection limitChromatographySodiumBiophysicsElectrophoresis CapillaryReproducibility of Resultschemistry.chemical_elementAscorbic AcidCell BiologyElectrolytePlantsAscorbic acidSensitivity and SpecificityBiochemistryElectrophoresischemistry.chemical_compoundCapillary electrophoresischemistryBromideDehydroascorbic acidMolecular BiologyAnalytical Biochemistry
researchProduct

A rapid and reliable size-exclusion chromatographic method for determination of kojic dipalmitate in skin-whitening cosmetic products

2007

A size-exclusion chromatographic method has been developed to determine the relatively novel skin-whitening agent called kojic dipalmitate (KDP) in skin-whitening cosmetic products. Preliminary experiments were carried out in order to select the solvent for standard and sample solution, and also for mobile phase composition. A PLGel Mixed-D (polystyrene/divinylbenzene co-polymer) column and isocratic mobile phase of pure tetrahydrofuran (at 1.5 mL min(-1) flow rate) were used. Detection was carried out by means of an UV/vis spectrometry detector set at 248 nm. A study of interferences reveals that KDP can be determined without interferences coming from cosmetic matrices. Most other cosmetic…

Detection limitChromatographymedicine.diagnostic_testSize-exclusion chromatographyReproducibility of ResultsSkin PigmentationSkin whiteningCosmeticsDivinylbenzeneSensitivity and SpecificityAnalytical ChemistrySolventGel permeation chromatographychemistry.chemical_compoundchemistryPyronesSpectrophotometryChromatography GelmedicineSpectrophotometry UltravioletCosmetic industryTalanta
researchProduct

Matrix solid-phase dispersion extraction procedure for multiresidue pesticide analysis in oranges.

1996

A multiresidue extraction method based on matrix solid-phase dispersion (MSPD) is optimized for the extraction and gas chromatographic screening of eighteen insecticides (aldrin, carbophenothion, captafol, chlorpyriphos, chlorfenvinphos, diazinon, dicofol, alpha-endosulfan, beta-endosulfan, ethion, fenitrothion, folpet, methidathion, malathion, methyl-azinphos, methyl-parathion, phosmet, and tetradifon) from oranges. After optimization of different parameters, such as type of solid phase used and the amount of solid phase or eluent, recoveries ranged from 67 to 102% with relative standard deviations ranging from 2 to 10%. The limits of detection, calculated as 3 times the baseline noise ran…

Detection limitCitrusChromatographyChromatography GasPesticide residueMicrochemistryOrganic ChemistryAnalytical chemistryPesticide ResiduesGeneral MedicinePhosmetMethidathionAcetatesEthionBiochemistrySensitivity and SpecificityAnalytical ChemistryTetradifonchemistry.chemical_compoundchemistryCarbophenothionSolventsAldrinJournal of chromatography. A
researchProduct

Development of a pressurised liquid extraction and liquid chromatography with electrospray ionization-tandem mass spectrometry method for the determi…

2006

Amnesic shellfish poisoning (ASP) is a potentially lethal human toxic syndrome which is caused by domoic acid (DA) that originates in marine phytoplankton belonging to the Pseudonitzschia genus. A confirmatory and sensitive procedure has been developed and validated for the determination of DA in shellfish. The proposed method includes pressurised liquid extraction (PLE) with methanol/acetone (9:1), florisil ® cleanup purification inside the PLE extraction cell and detection by liquid chromatography (LC) coupled to electrospray ionization in positive mode tandem mass spectrometry (ESI-MS–MS). Comparison of ionization sources (ESI, atmospheric pressure ionization (APCI) atmospheric pressure …

Detection limitElectrospraySpectrometry Mass Electrospray IonizationChromatographyKainic AcidElectrospray ionizationOrganic ChemistryAnalytical chemistryDomoic acidAtmospheric-pressure chemical ionizationGeneral MedicineTandem mass spectrometryBiochemistryHigh-performance liquid chromatographySensitivity and SpecificityAnalytical Chemistrychemistry.chemical_compoundchemistryTandem Mass SpectrometryAmnesic shellfish poisoningAnimalsChromatography LiquidShellfishJournal of chromatography. A
researchProduct

Liquid chromatographic determination of trimethylamine in water.

2004

A method for the selective determination of trimethylamine (TMA) in aqueous matrices by liquid chromatography is reported. The proposed procedure is based on the derivatization of the analyte with 9-fluorenylmethyl chloroformate (FMOC) in a precolumn (Hypersil C18, 30 microm, 20 mm x 2.1 mm i.d.) connected on-line to the analytical column (LiChrosphere 100 RP18, 5 microm, 125 mm x 4 mm i.d.). Gradient elution was performed with a mixture of acetonitrile-water-0.05 M borate buffer (pH 9.0). The method has been applied to the direct determination of TMA in water within the 0.25-10.0 microg/ml concentration interval, and can also be adapted to the determination of TMA over the range 0.05-1.0 m…

Detection limitFluorenesChromatographyTertiary amineChemistryOrganic ChemistryWaterTrimethylamineGeneral MedicineReversed-phase chromatographyChloroformateSensitivity and SpecificityBiochemistryAnalytical ChemistryMethylamineschemistry.chemical_compoundSample preparationSolid phase extractionDerivatization
researchProduct

Determination of organophosphorus pesticides in honeybees after solid-phase microextraction.

2001

A method based on solid-phase microextraction (SPME) followed by gas chromatography with nitrogen-phosphorus detection was developed for the purpose of determining 18 organophosphorus pesticide residues in honeybee samples (Apis mellifera). The extraction capacities of polyacrylate and poly(dimethylsiloxane) fibers were compared. The main factors affecting the SPME process, such as the absorption time profile, salt, and temperature, were optimized. The method involved honeybee sample homogenization, elution with an acetone:water solution (1:1) and dilution in water prior to fiber extraction. Moreover, the matrix effect on the extraction was evaluated. In samples spiked at the 0.2 mg kg(-1) …

Detection limitInsecticidesChromatographyChemistryElutionOrganic ChemistryExtraction (chemistry)Osmolar ConcentrationTemperatureGeneral MedicineBeesSolid-phase microextractionBiochemistrySensitivity and SpecificityAnalytical ChemistryDilutionOrganophosphorus CompoundsSolventsAnimalsSample preparationSaltsSolid phase extractionGas chromatographyJournal of chromatography. A
researchProduct

Development of an ICP-IDMS method for accurate routine analyses of toxic heavy metals in polyolefins and comparison with results by TI-IDMS

2000

An inductively coupled plasma isotope dilution mass spectrometric (ICP-IDMS) method was developed as a suitable method - with respect to its sensitivity, precision, accuracy, and time-consumption - for the analysis of toxic heavy metal traces (Pb, Cd, Cr, and Hg) in polyolefins. Results for Pb, Cd, and Cr were compared with those obtained by thermal ionization isotope dilution mass spectrometry (TI-IDMS), which was used as a reference method. Because of its high first ionization potential and its high volatility mercury could not be determined by TI-IDMS. A multi-element spike solution, containing isotopically enriched 206Pb, 116Cd, 53Cr, and 201Hg, was used for the isotope dilution step. D…

Detection limitIsotopeChemistryAnalytical chemistryThermal ionizationchemistry.chemical_elementAlkenesIsotope dilutionMass spectrometrySensitivity and SpecificityBiochemistryHazardous SubstancesMass SpectrometryMercury (element)IsotopesPolyethyleneMetals HeavyInductively coupled plasmaChemical decompositionFresenius' Journal of Analytical Chemistry
researchProduct