Search results for "Spectral"
showing 10 items of 3116 documents
Study of encapsulated T170m sources for their potential use in brachytherapy
2010
Purpose: High dose-rate (HDR) brachytherapy is currently performed with {sup 192}Ir sources, and {sup 60}Co has returned recently into clinical use as a source for this kind of cancer treatment. Both radionuclides have mean photon energies high enough to require specific shielded treatment rooms. In recent years, {sup 169}Yb has been explored as an alternative for HDR-brachytherapy implants. Although it has mean photon energy lower than {sup 192}Ir, it still requires extensive shielding to deliver treatment. An alternative radionuclide for brachytherapy is {sup 170}Tm (Z=69) because it has three physical properties adequate for clinical practice: (a) 128.6 day half-life, (b) high specific a…
Exploring 10 Gb/s transmissions in Titanium dioxide based waveguides at 1.55 pm and 2.0 pm
2017
Exploring new spectral bands for optical transmission is one of the solutions to support the increasingly demand of data traffic. The recent development of dedicated hollow-core photonic bandgap fibers [1], associated to the emergence of thulium doped fiber amplifiers [2] has recently focused the attention further in the infrared, and more specifically around 2 μm. Regarding integrated photonics, it becomes therefore interesting to find a suitable platform to operate at 2 μm as well as in the other more conventional spectral bands (going from 800 nm to 1550 nm). Here, we propose titanium dioxide (TiO 2 ) as a good candidate for integrated waveguide photonics and demonstrate, for the first t…
Clinical measurements analysis of multi-spectral photoplethysmograph biosensors
2014
The developed portable multi-spectral photoplethysmograph (MS-PPG) optical biosensor device, intended for analysis of peripheral blood volume pulsations at different vascular depths, has been clinically verified. Multi-spectral monitoring was performed by means of a four – wavelengths (454 nm, 519 nm, 632 nm and 888 nm) light emitted diodes and photodiode with multi-channel signal output processing. Two such sensors can be operated in parallel and imposed on the patient’s skin. The clinical measurements confirmed ability to detect PPG signals at four wavelengths simultaneously and to record temporal differences in the signal shapes (corresponding to different penetration depths) in normal a…
Clinical measurements with multi-spectral photoplethysmography sensors
2012
A portable multi-spectral photoplethysmography device has been used for studies of 40 subjects. Multi-spectral monitoring was performed by means of a four - wavelengths (465 nm, 530 nm, 630 nm and 870 nm) light emitted diodes (LED) and a single photodiode with multi-channel signal output processing. The proposed methodology and potential clinical applications are discussed.
Autofluorescence spectroscopy of cutaneous neoplasia under ultraviolet, visible and near infrared excitation
2020
We investigated melanin-pigmented skin samples ex vivo, of benign and dysplastic nevi, as well as malignant melanoma, obtained after surgical excision, containing so called safety areas, where a normal skin could be observed, to obtain a complex and complete view about the feasibility of different excitation sources solely and/or in combination to induce fluorescence signal useful for diagnosis of pigmented cutaneous neoplasia. Using the specialized multispectral analysis of the data obtained by fluorescence using excitation in broad spectral range, covering ultraviolet, visible and near-infrared spectral range, contribute considerably to the both the fundamental determination of tumour tis…
Raman spectra of (PbS)1.18(TiS2)2 misfit compound
2007
Abstract A Raman study on the (PbS)1.18(TiS2)2 semiconductor structure with incommensurate layers (misfit) is reported. The different bands observed in the spectra are attributed to both the TiS2 host layers, at 219 (Eg) and 333 (A1g) cm−1, and the intercalated PbS layers: the LO(Γ), 2LO and 3LO phonons at 203, 412 and 634 cm−1, respectively. A phonon peak probably related to the superposition of TiS2 and PbS vibrations, was observed near 286 cm−1. The decrease of the phonon wave numbers (of the modes located at 203, 333, 412, and 634 cm−1) with increasing laser power pointed out negative temperature coefficients of these modes. A peak appearing with laser power near 151 cm−1 is discussed. …
Broadband Fabry–Pérot Resonator From Zerodur for Laser Stabilisation Below 1KHZ Linewidth With < 100 HZ/S Drift and Reduced Sensitivity to Vibrati…
2015
Abstract Here we demonstrate the results of creating a two-mirror Fabry-Pérot resonator (FPR) that allows achieving the spectral width of a stabilised laser line below 1 kHz. It had low expansion Zerodur spacer and broadband high reflectance mirrors (99.85% in the range of 630 to 1140 nm). FPR was vertically mid-plane mounted for reduced sensitivity to vibrations and included in two shields inside a vacuum chamber to lower temperature fluctuations. Peltier element was used for temperature stabilisation at zero-expansion temperature. Pound-Drever-Hall (PDH) technique was applied. The signal from FPR was compared to ultra-stable signal (of about 1 Hz linewidth) to form a beat note signal. For…
Tapering photonic crystal fibres for supercontinuum generation with nanosecond pulses at 532nm
2008
Experimental results on supercontinuum generation in photonic crystal fibre tapers using pump pulses of 7 ns duration at 532 nm are presented. Photonic crystal fibre tapers with the first wavelength of zero dispersion around 532 nm were fabricated. The generation of supercontinuum was investigated in normal and anomalous dispersion regimes. Supercontinuum spectra spanning more than 400 nm in the visible region are reported.
Tuning of High-Order Harmonics for Soft X-Ray Laser Seeding
2011
Within this work we present results of an experimental campaign studying the influence of the adiabatic and non-adiabatic blue shift on high-order harmonic (HH) radiation spectra. The results demonstrate that we are able to spectrally tune the HH radiation to cover more than 50% of the spectrum between 17 nm and 35 nm, paving the way to performing injection-seeded soft X-ray laser (SXRL) experiments with Mo, Zr and Y.
Affordable, ultra-broadband coherent detection of terahertz pulses via CMOS-compatible solid-state devices
2017
We demonstrate the first fully solid-state technique for the coherent detection of ultra-broadband THz pulses (0.1-10 THz), relying on the electric-field-induced second-harmonic generation attained in integrated CMOS-compatible devices.