Search results for "Spectrometer"
showing 10 items of 751 documents
Analysis of fumonisins B1, B2 and B3 in corn-based baby food by pressurized liquid extraction and liquid chromatography/tandem mass spectrometry
2008
A sensitive and reliable method using pressurized liquid extraction (PLE) and liquid chromatography (LC)/electrospray ionization (ESI) tandem mass spectrometry with a triple quadrupole (QqQ) analyzer has been developed for the analysis of fumonisin B(1) (FB(1)), fumonisin B(2) (FB(2)) and fumonisin B(3) (FB(3)) in corn-based baby foods. Influence of several extraction parameters that affect PLE efficiency such as temperature, pressure, solvent extraction, number of cycles and dispersant/clean-up agents were studied. The selected PLE operating method was: 3g of sample was packed into 11 ml stainless-steel cell and fumonisins were extracted with methanol at 40 degrees C, 34 atm in one cycle o…
Geomaterials in green building practices: comparative characterization of commercially available clay-based plasters
2013
Three pre-mixed powdered clay-based (earthen) plasters produced in Europe and specifically designed for wall undercoating were analyzed in this paper. These materials are commercially available and successfully employed in green building practices all over the world. Their compositional and textural characteristics, as well as plastic behaviour were investigated through a multi-analytical approach: X-ray powder diffraction (XRPD), polarized light microscopy (PLM), X-ray fluorescence spectrometry (XRFS), scanning electron microscopy equipped with an energy dispersive spectrometer (SEM-EDS), mercury intrusion porosimetry (MIP), grain-size distribution (GSD) and semi-empirical tests (Atterberg…
Characterization of the Etna volcanic emissions through an active biomonitoring technique (moss-bags): Part 2 – Morphological and mineralogical featu…
2013
Volcanic emissions were studied at Mount Etna (Italy) by using moss-bags technique. Mosses were exposed around the volcano at different distances from the active vents to evaluate the impact of volcanic emissions in the atmosphere. Morphology and mineralogy of volcanic particulate intercepted by mosses were investigated using scanning electron microscopy (SEM) equipped with energy dispersive spectrometer (EDS). Particles emitted during passive degassing activity from the two active vents, Bocca Nuova and North East Crater (BNC and NEC), were identified as silicates, sulfates and halide compounds. In addition to volcanic particles, we found evidences also of geogenic, anthropogenic and marin…
Configurable bandwidth imaging spectrometer based on acousto-optic tunable filter
2005
This paper presents a new portable instrument called Autonomous Tunable Filtering System (ATFS), developed for highly customisable imaging spectrometry in the VIS-NIR range. The ATFS instrument consists of an Acousto-Optic Tunable Filter (AOTF), an optical system, a Radio Frequency (RF) driver based on a Direct Digital Synthesiser (DDS) and control software. The ATFS can be attached to a variety of high-performance monochrome cameras. The system works as a spectral bandpass filter whose wavelength can be selected between 400nm and 1000nm and whose bandwidth can be adjusted between 4nm and 50nm. The filter can be tuned electronically at a very high speed and accuracy, thanks to the DDS versa…
Crossing the dripline to11Nusing elastic resonance scattering
2000
The level structure of the unbound nucleus N-11 has been studied by C-10+p elastic resonance scattering in inverse geometry with the LISE3 spectrometer at GANIL, using a C-10 beam with an energy of 9.0 MeV/ nucleon. An additional measurement was done at the A1200 spectrometer at MSU. The excitation function above the C-10+p threshold has been determined up to 5 MeV. A potential-model analysis revealed three resonance states at energies 1.27(-0.05)(+0.18) MeV (Gamma = 1.44 +/- 0.2 MeV), 2.01(-0.05)(+0.15) MeV (Gamma = 0.84 +/- 0.2 MeV), and 3.75 +/- 0.05 MeV (Gamma = 0.60 +/- 0.05 MeV) with the spin-parity assignments I-pi=1/2+,1/2,-,5/2+, respectively. Hence, N-11 is shown to have a ground …
Multinucleon transfer reactions and proton transfer channels
2019
Transfer reactions have always been of great importance for nuclear structure and reaction mechanism studies. So far, in multinucleon transfer studies, proton pickup channels have been completely identified in atomic and mass numbers at energies close to the Coulomb barrier only in few cases. We measured the multinucleon transfer reactions in the 40Ar+208Pb system near the Coulomb barrier, by employing the PRISMA magnetic spectrometer. By using the most neutron-rich stable 40Ar beam we could populate, besidesneutron pickup and proton stripping channels, also neutron stripping and proton pickup channels. Comparison ofcross sections between different systems with the 208Pb target and with pro…
Protocols for UV camera volcanic SO2 measurements
2010
Abstract Ultraviolet camera technology offers considerable promise for enabling 1 Hz timescale acquisitions of volcanic degassing phenomena, providing two orders of magnitude improvements on sampling frequencies from conventionally applied scanning spectrometer systems. This could, for instance enable unprecedented insights into rapid processes, such as strombolian explosions, and non-aliased corroboration with volcano geophysical data. The uptake of this technology has involved disparate methodological approaches, hitherto. As a means of expediting the further proliferation of such systems, we here study these diverse protocols, with the aim of suggesting those we consider optimal. In part…
Probing the physics of the solar atmosphere with the Multi-slit Solar Explorer (MUSE): I. Coronal Heating
2022
The Multi-slit Solar Explorer (MUSE) is a proposed NASA MIDEX mission, currently in Phase A, composed of a multi-slit EUV spectrograph (in three narrow spectral bands centered around 171A, 284A, and 108A) and an EUV context imager (in two narrow passbands around 195A and 304A). MUSE will provide unprecedented spectral and imaging diagnostics of the solar corona at high spatial (<0.5 arcsec), and temporal resolution (down to ~0.5s) thanks to its innovative multi-slit design. By obtaining spectra in 4 bright EUV lines (Fe IX 171A , Fe XV 284A, Fe XIX-Fe XXI 108A) covering a wide range of transition region and coronal temperatures along 37 slits simultaneously, MUSE will for the first time …
iLocater: a diffraction-limited Doppler spectrometer for the Large Binocular Telescope
2016
We are developing a stable and precise spectrograph for the Large Binocular Telescope (LBT) named "iLocater." The instrument comprises three principal components: a cross-dispersed echelle spectrograph that operates in the YJ-bands (0.97-1.30 microns), a fiber-injection acquisition camera system, and a wavelength calibration unit. iLocater will deliver high spectral resolution (R~150,000-240,000) measurements that permit novel studies of stellar and substellar objects in the solar neighborhood including extrasolar planets. Unlike previous planet-finding instruments, which are seeing-limited, iLocater operates at the diffraction limit and uses single mode fibers to eliminate the effects of m…
Future use of silicon photomultipliers for Kaos at MAMI and P¯ANDA at FAIR
2009
A characterisation of scintillating fibres with silicon photomultiplier read-out was performed in view of their possible application in fibre tracking detector systems. Such a concept is being considered for the Kaos spectrometer at the Mainz Microtron MAMI and as a time-of-flight start detector for the hypernuclear physics programme at the PANDA experiment of the FAIR project. Results on particle detection effciency and time resolution are discussed. In summary, the silicon devices are very suitable for the detection of the low light yield from scintillating fibres insofar a trigger scheme is found to cope with the noise rate characteristics.