Search results for "Spectrometer"
showing 10 items of 751 documents
EDGE: explorer of diffuse emission and gamma-ray burst explosions
2009
How structures on various scales formed and evolved from the early Universe up to present time is a fundamental question of astrophysical cosmology. EDGE will trace the cosmic history of the baryons from the early generations of massive star by Gamma-Ray Burst (GRB) explosions, through the period of cluster formation, down to very low redshifts, when between a third and one half of the baryons are expected to reside in cosmic filaments undergoing gravitational collapse by dark matter (Warm Hot Intragalactic Medium: WHIM). In addition EDGE, with its unprecedented observational capabilities, will provide key results on several other topics. The science is feasible with a medium class mission …
Resolution of the ATLAS muon spectrometer monitored drift tubes in LHC Run 2
2019
The momentum measurement capability of the ATLAS muon spectrometer relies fundamentally on the intrinsic single-hit spatial resolution of the monitored drift tube precision tracking chambers. Optimal resolution is achieved with a dedicated calibration program that addresses the specific operating conditions of the 354 000 high-pressure drift tubes in the spectrometer. The calibrations consist of a set of timing offsets and drift time to drift distance transfer relations, and result in chamber resolution functions. This paper describes novel algorithms to obtain precision calibrations from data collected by ATLAS in LHC Run 2 and from a gas monitoring chamber, deployed in a dedicated gas fac…
The Wide Field Imager of the International X-ray Observatory
2010
The International X-ray Observatory (IXO) will be a joint X-ray observatory mission by ESA, NASA and JAXA. It will have a large effective area (3 m 2 at 1.25 keV) grazing incidence mirror system with good angular resolution (5 arcsec at 0.1–10 keV) and will feature a comprehensive suite of scientific instruments: an X-ray Microcalorimeter Spectrometer, a High Time Resolution Spectrometer, an X-ray Polarimeter, an X-ray Grating Spectrometer, a Hard X-ray Imager and a Wide-Field Imager. The Wide Field Imager (WFI) has a field-of-view of 18 ft � 18 ft. It will be sensitive between 0.1 and 15 keV, offer the full angular resolution of the mirrors and good energy resolution. The WFI will be imple…
The IXO Wide-Field Imager
2010
The Wide Field Imager (WFI) of the International X-ray Observatory (IXO) is an X-ray imaging spectrometer based on a large monolithic DePFET (Depleted P-channel Field Effect Transistor) Active Pixel Sensor. Filling an area of 10 × 10 cm² with a format of 1024 × 1024 pixels it will cover a field of view of 18 arcmin. The pixel size of 100 × 100 μm² corresponds to a fivefold oversampling of the telescope's expected 5 arcsec point spread function. The WFI's basic DePFET structure combines the functionalities of sensor and integrated amplifier with nearly Fano-limited energy resolution and high efficiency from 100 eV to 15 keV. The development of dedicated control and amplifier ASICs allows for…
The wide-field imager for IXO: status and future activities
2010
The Wide Field Imager (WFI) of the International X-ray Observatory (IXO) is an X-ray imaging spectrometer based on a large monolithic DePFET (Depleted P-channel Field Effect Transistor) Active Pixel Sensor. Filling an area of 10 x 10 cm2 with a format of 1024 x 1024 pixels it will cover a field of view of 18 arcmin. The pixel size of 100 x 100 μm2 corresponds to a fivefold oversampling of the telescope's expected 5 arcsec point spread function. The WFI's basic DePFET structure combines the functionalities of sensor and integrated amplifier with nearly Fano-limited energy resolution and high efficiency from 100 eV to 15 keV. The development of dedicated control and amplifier ASICs allows for…
Design and optimization of the wide-field spectrometer for EDGE mission
2007
Optical diagnostic method for benzene detection in air
2014
In this paper we show our first results of research for creation a detector for benzene vapor and possibly other volatile organic compounds detection in air based on Zeeman atomic absorption technique. First the detailed study of benzene absorption spectra with high resolution spectrometer Jobin-Yvon 1000M was done. The absorption spectra of benzene were registered in the spectral range from 200-900 nm. More detailed analysis was done for the 240 – 260 nm spectral range to test a possibility to detect benzene by means of emission line of 254 nm of mercury.
<title>Deconvolution of the mercury 253.7 nm spectral line shape for the use in absorption spectroscopy</title>
2008
In this work we present measurement and results of the deconvolution of the Hg 253.7 nm spectral line shapes, emitted from the mercury isotope high-frequency electrodeless discharge lamps, made at the Institute of Atomic Physics and Spectroscopy for the use in Zeeman Atomic Absorption Spectrometry. The emission line profiles of 254 nm Hg resonance line have been measured by means of a Zeeman scanning spectrometer at the mercury cold spot temperature value at 20 C. Then the deconvolution procedure or solving of this ill-posed inverse problem by means of the Tikhonov's regularization method [1] was performed to obtain the real spectral line shape.© (2008) COPYRIGHT SPIE--The International Soc…
<title>Advanced light sources for atomic absorption analysis</title>
2003
High-frequency electrodeless light sources (HF EDLS) are widely used as bright radiators of narrow and intensive atomic and ionic spectral lines, covering the spectrum from VUV to IR. Main characteristics of HF EDLS are high emitted spectral line intensity, long service life, and in general, narrow spectral line shapes because of low-pressure of filling elements. In this work we give a short overview of the use of HF EDLS, containing Hg, Te, Se, Zn, Pb, As, Sb, Bi, Tl, In, Cd, Sn, in Zeeman Atomic absorption devices for assaying natural, drinking, waste and technical water as well as air, soil, food products and biological samples. The first steps are made for optimization of Ge, Ga, P, S, …
The proton radius puzzle
2017
High-precision measurements of the proton radius from laser spectroscopy of muonic hydrogen demonstrated up to six standard deviations smaller values than obtained from electron-proton scattering and hydrogen spectroscopy. The status of this discrepancy, which is known as the proton radius puzzle will be discussed in this paper, complemented with the new insights obtained from spectroscopy of muonic deuterium.