Search results for "Spectrometer"
showing 10 items of 751 documents
Measurement of the spin-dependent structure function g1(x) of the deuteron
1993
We report on the first measurement of the spin-dependent structure function g1d of the deuteron in the deep inelastic scattering of polarised muons off polarised deuterons, in the kinematical range 0.006<x<0.6, 1 GeV2<Q2<30 GeV2. The first moment, Γ1d=sh{phonetic}01 g1d dx=0.023±0.020 (stat.) ± 0.015 (syst.), is smaller than the prediction of the Ellis-Jaffe sum rules. Using earlier measurements of g1p, we infer the first moment of the spin-dependent neutron structure function g1n. The difference Γ1p-Γ1n=0.20 ±0.05 (stat.) ± 0.04 (syst.) agrees with the prediction of the Bjorken sum rule, Γ1p-Γ1n=0.191 ±0.002.
Measuring nuclear reaction cross sections to extract information on neutrinoless double beta decay
2017
Neutrinoless double beta decay (0v\b{eta}\b{eta}) is considered the best potential resource to access the absolute neutrino mass scale. Moreover, if observed, it will signal that neutrinos are their own anti-particles (Majorana particles). Presently, this physics case is one of the most important research "beyond Standard Model" and might guide the way towards a Grand Unified Theory of fundamental interactions. Since the 0v\b{eta}\b{eta} decay process involves nuclei, its analysis necessarily implies nuclear structure issues. In the NURE project, supported by a Starting Grant of the European Research Council (ERC), nuclear reactions of double charge-exchange (DCE) are used as a tool to extr…
Measurement of the energy distribution of electrons escaping minimum-B ECR plasmas
2017
The measurement of the electron energy distribution (EED) of electrons escaping axially from a minimum-B electron cyclotron resonance ion source (ECRIS) is reported. The experimental data were recorded with a room-temperature 14 GHz ECRIS at the JYFL accelerator laboratory. The electrons escaping through the extraction mirror of the ion source were detected with a secondary electron amplifier placed downstream from a dipole magnet serving as an electron spectrometer with 500 eV resolution. It was discovered that the EED in the range of 5–250 keV is strongly non-Maxwellian and exhibits several local maxima below 20 keV energy. It was observed that the most influential ion source operating pa…
Diseño físico-matemático de un espectrómetro óptico
2016
[EN] This work presents the design and construction of a spectrometer made in the laboratory and the development of mathematical models needed to process and analyze the acquired spectrum. For modeling functions it has been used LabVIEW program. The aim is to bring this type of instrumentation to engineering students from both, physical and mathematical point of view. The application has been successfully integrated in the learning strategies of the course Sensores Fisicos, Master Universitario en Sensores Para Aplicaciones Industriales at the Universitat Politecnica de Valencia. As an example, we have characterized different light sources emitting in different regions of the electromagneti…
2017
Abstract. Remote sensing of the gaseous composition of non-eruptive, passively degassing volcanic plumes can be a tool to gain insight into volcano interior processes. Here, we report on a field study in September 2015 that demonstrates the feasibility of remotely measuring the volcanic enhancements of carbon dioxide (CO2), hydrogen fluoride (HF), hydrogen chloride (HCl), sulfur dioxide (SO2), and bromine monoxide (BrO) in the downwind plume of Mt. Etna using portable and rugged spectroscopic instrumentation. To this end, we operated the Fourier transform spectrometer EM27/SUN for the shortwave-infrared (SWIR) spectral range together with a co-mounted UV spectrometer on a mobile platform in…
A multi-purpose, multi-rotor drone system for long-range and high-altitude volcanic gas plume measurements
2021
A multi-rotor drone has been adapted for studies of volcanic gas plumes. This adaptation includes improved capacity for high-altitude and long-range, real-time SO2 concentration monitoring, long-range manual control, remotely activated bag sampling and plume speed measurement capability. The drone is capable of acting as a stable platform for various instrument configurations, including multi-component gas analysis system (MultiGAS) instruments for in situ measurements of SO2, H2S, and CO2 concentrations in the gas plume and portable differential optical absorption spectrometer (MobileDOAS) instruments for spectroscopic measurement of total SO2 emission rate, remotely controlled gas samplin…
Recent advances in ground-based ultraviolet remote sensing of volcanic SO2 fluxes
2011
Measurements of volcanic SO2 emission rates have been the mainstay of remote-sensing volcanic gas geochemistry for almost four decades, and they have contributed significantly to our understanding of volcanic systems and their impact upon the atmosphere. The last ten years have brought step-change improvements in the instrumentation applied to these observations, which began with the application of miniature ultraviolet spectrometers that were deployed in scanning and traverse configurations, with differential optical absorption spectroscopy evaluation routines. This study catalogs the more recent empirical developments, including: ultraviolet cameras; wide-angle field-of-view differential …
Unmanned aerial vehicle measurements of volcanic carbon dioxide fluxes
2008
[i] We report the first measurements of volcanic gases with an unmanned aerial vehicle (UAV). The data were collected at La Fossa crater, Vulcano, Italy, during April 2007, with a helicopter UAV of 3 kg payload, carrying an ultraviolet spectrometer for remotely sensing the SO 2 flux (8.5 Mg d- 1 ), and an infrared spectrometer, and electrochemical sensor assembly for measuring the plume CO 2 /SO 2 ratio; by multiplying these data we compute a CO 2 flux of 170 Mg d -1 . Given the deeper exsolution of carbon dioxide from magma, and its lower solubility in hydro-thermal systems, relative to SO 2 , the ability to remotely measure CO 2 fluxes is significant, with promise to provide more profound…
First measurement of proton's charge form factor at very low $Q^2$ with initial state radiation
2017
We report on a new experimental method based on initial-state radiation (ISR) in e-p scattering, in which the radiative tail of the elastic e-p peak contains information on the proton charge form factor ($G_E^p$) at extremely small $Q^2$. The ISR technique was validated in a dedicated experiment using the spectrometers of the A1-Collaboration at the Mainz Microtron (MAMI). This provided first measurements of $G_E^p$ for $0.001\leq Q^2\leq 0.004 (GeV/c)^2$.
Transverse momentum distributions for exclusive $\varrho^{0}$ muoproduction
1992
We have studied transverse momentum distributions for exclusive rho(0) muoproduction on protons and heavier nuclei at 2 < Q2 < 25 GeV2. The Q2 dependence of the slopes of the p(t)2 and t' distributions is discussed. The influence of the non-exclusive background is investigated. The p(t)2-slope for exclusive events is 4.3 +/- 0.6 +/- 0.7 GeV-2 at large Q2. The p(t)2 spectra are much softer than inclusive p(t)2 spectra of leading hadrons produced in deep inelastic scattering.