Search results for "Spectrometry"

showing 10 items of 3206 documents

A comparative study of the performance of acetonitrile and methanol in the multi-linear gradient separation of proteic primary amino acids

2006

The performance of the separation of proteic primary amino acids using multi-linear gradients of acetonitrile and methanol was studied under an experimental-design basis, using an Inertsil ODS-3 column and pre-column derivatization with o-phthaldialdehyde (OPA) and N-acetyl-l-cysteine (NAC). Elution strength, peak properties, resolution, and analysis time, were examined. The optimal separation was established through modeling, using information obtained from isocratic data. By optimizing the separation with gradients of increasing complexity, acceptable resolution was possible, being glycine/threonine the critical pair. Multi-criteria decision-making (Derringer desirabilities) was applied t…

AcetonitrilesChromatographyResolution (mass spectrometry)ElutionMethanolAnalytical chemistryProteinsReversed-phase chromatographyBiochemistryAnalytical ChemistryPrimary amino acidschemistry.chemical_compoundchemistryGlycineEnvironmental ChemistryMethanolAmino AcidsDerivatizationAcetonitrileSpectroscopyAnalytica Chimica Acta
researchProduct

Interpretive optimisation strategy applied to the isocratic separation of phenols by reversed-phase liquid chromatography with acetonitrile–water and…

2000

An optimisation protocol is presented for the resolution of complex mixtures in isocratic RPLC with binary mobile phases of organic solvent and water, which is based on the prediction of peak position and shape of the individual compounds. A good description of the retention was achieved through the application of statistical weights to the widely used linear or quadratic relationships between the logarithm of the retention factor (log k) and the organic solvent concentration in the mobile phase. The maximisation of the product of peak purities for each compound is shown as a competitive resolution strategy versus the worst value of a selectivity parameter. Peak purities allow one to associ…

AcetonitrilesChromatographyResolution (mass spectrometry)ElutionMethanolOrganic ChemistryAnalytical chemistryWaterGeneral MedicineCresolReversed-phase chromatographyBiochemistryHigh-performance liquid chromatographyAnalytical Chemistrychemistry.chemical_compoundPhenolschemistryXylenolPhase (matter)medicineAcetonitrileChromatography Liquidmedicine.drugJournal of Chromatography A
researchProduct

A chromatographic objective function to characterise chromatograms with unknown compounds or without standards available

2015

Abstract Getting useful chemical information from samples containing many compounds is still a challenge to analysts in liquid chromatography. The highest complexity corresponds to samples for which there is no prior knowledge about their chemical composition. Computer-based methodologies are currently considered as the most efficient tools to optimise the chromatographic resolution, and further finding the optimal separation conditions. However, most chromatographic objective functions (COFs) described in the literature to measure the resolution are based on mathematical models fitted with the information obtained from standards, and cannot be applied to samples with unknown compounds. In …

AcetonitrilesChromatographyResolution (mass spectrometry)Plant ExtractsChemistryElutionOrganic ChemistryAnalytical chemistryWaterGeneral MedicineBiochemistryAnalytical ChemistryPharmaceutical PreparationsSolventsGradient elutionMedicinal herbsDrug ContaminationChromatography LiquidJournal of Chromatography A
researchProduct

Optimised procedures for the reversed-phase liquid chromatographic analysis of formulations containing tricyclic antidepressants.

2003

The chromatographic behaviour (retention, selectivity, peak shape and resolution) of seven tricyclic antidepressants (TCAs), amitryptiline, clomipramine, doxepin, imipramine, maprotiline, nortryptiline and trimipramine, was examined. Conventional unendcapped Cs and C18 columns and an endcapped XTerra MS C18 column recommended for the analysis of basic compounds were used together with acetonitrile-water and micellar sodium dodecylsulfate (SDS)-pentanol mobile phases. The two best combinations were XTerra C18/acetonitrile, which yielded the largest efficiencies and resolution, and C8/SDS-pentanol, which eliminated the peak tails that were still observed with the XTerra C18 column. Both the s…

AcetonitrilesResolution (mass spectrometry)Clinical BiochemistryPharmaceutical ScienceCapsulesAntidepressive Agents TricyclicSensitivity and SpecificityDosage formAnalytical Chemistrychemistry.chemical_compoundDrug DiscoverymedicineAcetonitrileSpectroscopyChromatography High Pressure LiquidChromatographyExtraction (chemistry)Reproducibility of ResultsReversed-phase chromatographyDoxepinTrimipraminechemistry1-PentanolSolventsmedicine.drugTabletsJournal of pharmaceutical and biomedical analysis
researchProduct

Reversed phase liquid chromatography for the enantioseparation of local anaesthetics in polysaccharide-based stationary phases. Application to biodeg…

2020

[EN] A comprehensive study on the chiral separation of bupivacaine, mepivacaine, prilocaine and propanocaine with eight commercial polysaccharide-based chiral stationary phases (CSPs) in reversed phase conditions compatible with MS detection is performed. Methanol and acetonitrile are used as organic modifiers. Retention and resolution values obtained for each compound in the different CSPs and mobile phases are compared. The polysaccharide-based CSPs tested present different enantioselectivity towards the analytes. From the results, the experimental conditions for determining the enantiomers of bupivacaine, mepivacaine, prilocaine and propanocaine in saline aqueous samples using MS detecti…

AcetonitrilesResolution (mass spectrometry)Mepivacaine010402 general chemistry01 natural sciencesBiochemistryAnalytical Chemistrychemistry.chemical_compoundReversed phase conditionsPolysaccharidesPhase (matter)medicineEnantioselective biodegradation studyAnesthetics LocalAcetonitrileLocal anaestheticsChromatography High Pressure LiquidChromatography Reverse-PhaseAqueous solutionChromatographyCellulose and amylose-based chiral stationary phasesMethanol010401 analytical chemistryOrganic ChemistryEnantioselective synthesisWaterStereoisomerismGeneral MedicineReversed-phase chromatography0104 chemical sciencesMolecular WeightBiodegradation EnvironmentalchemistryEnantiomermedicine.drugJournal of chromatography. A
researchProduct

Sample Preparation Improvement in Polycyclic Aromatic Hydrocarbons Determination in Olive Oils by Gel Permeation Chromatography and Liquid Chromatogr…

2005

Abstract The determination of 15 polycyclic aromatic hydrocarbons (PAHs) in olive oil samples has been improved in order to obtain a fast methodology with a low limit of detection through the combination of liquid–liquid extraction with acetonitrile and preparative gel permeation chromatography (GPC) prior to the injection of purified extracts into a C18 column. Acetonitrile–water was used as the mobile phase with a gradient from 50 to 95%, w/w, acetonitrile in 30 min. The oven temperature was maintained at 15°C, and fluorometric detection was made at a fixed excitation wavelength of 264 nm and variable, optimal emission wavelength for each analyte ranging from 352 nm for 11-H-benzo(b)fluor…

AcetonitrilesTime FactorsFluoreneChemistry Techniques AnalyticalAnalytical ChemistryGel permeation chromatographychemistry.chemical_compoundPlant OilsEnvironmental ChemistryFluorometryUltrasonicsSample preparationPolycyclic Aromatic HydrocarbonsOlive OilChromatography High Pressure LiquidPharmacologychemistry.chemical_classificationDetection limitFluorantheneFluorenesMethylene ChlorideChromatographyChemistryExtraction (chemistry)TemperatureSilicon DioxideSpectrometry FluorescenceHydrocarbonChromatography GelPyreneAgronomy and Crop ScienceChromatography LiquidFood ScienceJournal of AOAC INTERNATIONAL
researchProduct

Room temperature acid sonication ICP-MS multielemental analysis of milk

2005

Abstract Room temperature acid sonication of milk samples is proposed as a fast alternative methodology for the determination of the total content of 45 elements (Li, Al, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Rb, Sr, Y, Mo, Ag, Cd, In, Sn, U, Sb, Te, Cs, Ba, Hg, Pb, Bi, Th, La, Ce, Pr, Nd, Sm, Eu, Gd, Dy, Ho, Er, Tm, Yb, Lu, Hf and Ta) in milk by inductively coupled plasma mass spectrometry (ICP-MS). The aforementioned procedure involves a 10 min sample pre-treatment. Measurements were made in quantitative and semiquantitative (Totalquant ® ) modes of analysis using Rh as internal standard and Be, Ge, Tb and Re for internal calibration of the equipment in the semiquantitative mode. The…

Acid digestionIsotopeChemistrySonicationPolyatomic ionAnalytical chemistryMass spectrometryBiochemistryAnalytical ChemistryEnvironmental ChemistryIsobaric processDirect analysisInductively coupled plasma mass spectrometrySpectroscopyAnalytica Chimica Acta
researchProduct

Exposure assessment of Spanish lactating mothers to acrylamide via human biomonitoring.

2021

Abstract Acrylamide (AA) is an organic compound classified as “Probably carcinogenic to humans” (Group 2 A) that can be found principally in processed carbohydrate-rich foods and tobacco smoke. In humans, after exposure, AA is rapidly metabolized and excreted in urine, predominantly as N-acetyl-S-(2-carbamoylethyl)-l-cysteine (AAMA), N-acetyl-S-(2-carbamoyl-2-hydroxyethyl)-l-cysteine (GAMA3) and N-Acetyl-3-[(3-amino-3-oxopropyl)sulfinyl]-L-alanine (AAMA-Sul), which can be used as short-term biomarkers of exposure to AA. In this study, the presence of AA metabolites in urine samples of lactating mothers living in Spain (n = 114) was analyzed by “dilute and shoot” and liquid chromatography co…

AcrylamideChemistryMothersUrineBiochemistryHazard quotientTobacco smokeAcetylcysteinechemistry.chemical_compoundTandem Mass SpectrometryAcrylamideBiomonitoringToxicityHumansLactationFemaleFood scienceCarcinogenGeneral Environmental ScienceExposure assessmentBiological MonitoringChromatography LiquidEnvironmental research
researchProduct

Development of a sensitive method for the determination of acrylamide in coffee using high-performance liquid chromatography coupled to a hybrid quad…

2015

The emerging trend towards high-resolution mass spectrometry (MS) alternatives was evaluated by the application of Orbitrap MS for the determination of acrylamide in coffee samples. The high resolving power of the Orbitrap MS provided the high selectivity and sensitivity that enabled quantitative analysis of acrylamide in complex matrices, such as coffee. Several sample preparation methods and scanning modes of the MS (full MS, t-SIM, t-MS2) were assessed in order to optimise parameters of the analytical method. The final procedure involved the extraction of acrylamide with acetonitrile, solid-phase extraction with dispersive primary secondary amine (PSA) and amino columns, and the detectio…

AcrylamideChromatographyHealth Toxicology and MutagenesisExtraction (chemistry)Public Health Environmental and Occupational HealthAnalytical chemistryGeneral ChemistryGeneral MedicineRepeatabilityToxicologyMass spectrometryOrbitrapCoffeeHigh-performance liquid chromatographyMass Spectrometrylaw.inventionchemistry.chemical_compoundchemistrylawAcrylamideSample preparationQuantitative analysis (chemistry)Chromatography High Pressure LiquidFood ScienceFood Additives & Contaminants: Part A
researchProduct

A radiometric and petrographic approach to risk assessment at Alte Madonie Mounts region (Sicily, Italy)

2013

The main goal of this work was to assess the radiological hazard at Alte Madonie Mounts region (north-central Sicily, Italy) in response to rumours of an increase in the incidence of cancer in this area. A correlation between the natural radionuclide contents and the petrographic features of the soil and rock samples was also evaluated. A total of 41 samples of selected soils and rocks were collected, powdered, dried and sealed in 'Marinelli' beakers for 20 d prior to measurement to ensure that a radioactive equilibrium between (226)Ra and (214)Bi had been reached. A gamma-ray spectrometer was used to quantify the radioactivity concentrations. To determine (238)U and (232)Th activities, the…

ActiniumSettore ING-IND/20 - Misure E Strumentazione NucleariMineralogychemistry.chemical_elementRisk AssessmentNuclear physicsPetrographyRadiation MonitoringBackground RadiationSoil Pollutants RadioactiveRadiology Nuclear Medicine and imagingRadiometrySicilyRadioisotopesRadionuclideRadiationGeographyRadiological and Ultrasound TechnologyCarbonate radiaoctivity petrographyThoriumSettore GEO/07 - Petrologia E PetrografiaPublic Health Environmental and Occupational HealthThoriumGeneral MedicineSecular equilibriumUraniumSpectrometry GammaLinear relationshipchemistrySoil waterLinear ModelsPotassiumUraniumEnvironmental scienceRadiometric datingBismuthRadiumRadiation Protection Dosimetry
researchProduct