Search results for "Spectroscopic"
showing 10 items of 119 documents
XMM-Newton spectroscopy of the metal depleted T Tauri star TWA 5
2005
We present results of X-ray spectroscopy for TWA 5, a member of the young TW Hydrae association, observed with XMM-Newton. TWA~5 is a multiple system which shows Halpha emission, a signature typical of classical T Tauri stars, but no infrared excess. From the analysis of the RGS and EPIC spectra, we have derived the emission measure distribution vs. temperature of the X-ray emitting plasma, its abundances, and the electron density. The characteristic temperature and density of the plasma suggest a corona similar to that of weak-line T Tauri stars and active late-type main sequence stars. TWA 5 also shows a low iron abundance (~0.1 times the solar photospheric one) and a pattern of increasin…
Monte Carlo Markov Chain DEM reconstruction of isothermal plasmas
2012
In this paper, we carry out tests on the Monte Carlo Markov Chain (MCMC) technique with the aim of determining: 1) its ability to retrieve isothermal plasmas from a set of spectral line intensities, with and without random noise; 2) to what extent can it discriminate between an isothermal solution and a narrow multithermal distribution; and 3) how well it can detect multiple isothermal components along the line of sight. We also test the effects of 4) atomic data uncertainties on the results, and 5) the number of ions whose lines are available for the DEM reconstruction. We find that the MCMC technique is unable to retrieve isothermal plasmas to better than Delta log T = 0.05. Also, the DEM…
Fine structure in the beta-delayed proton decay of 33Ar
1996
9 pages, 2 figures, 2 tables.-- PACS nrs.: 21.60.Cs; 23.40.−s; 27.30.+t; 29.30.Ep.
Emission-Line Intensity Ratios in F[CLC]e[/CLC] [CSC]xvii[/CSC] Observed with a Microcalorimeter on an Electron Beam Ion Trap
2000
We report new observations of emission line intensity ratios of Fe XVII under controlled experimental conditions, using the National Institute of Standards and Technology electron beam ion trap (EBIT) with a microcalorimeter detector. We compare our observations with collisional-radiative models using atomic data computed in distorted wave and R-matrix approximations, which follow the transfer of the polarization of level populations through radiative cascades. Our results for the intensity ratio of the 2p6 1S0-2p53d 1P1 15.014 A line to the 2p6 1S0-2p53d 3D1 15.265 A line are 2.94 ± 0.18 and 2.50 ± 0.13 at beam energies of 900 and 1250 eV, respectively. These results are not consistent wit…
Combining HR-MAS and In Vivo MRI and MRSI Information for Robust Brain Tumor Recognition
2009
In this study we propose to classify short echotime brain MRSI data by using multimodal information coming from magnetic resonance imaging (MRI), magnetic resonance spectroscopic imaging (MRSI) and high resolution magic angle spinning (HR-MAS), and to develop an advanced pattern recognition method that could help clinicians in diagnosing brain tumors. We study the impact of using HR-MAS information in combination with in vivo information for classifying brain tumors and we investigate which parameters influence our classification results.
Thermal structure of a hot non-flaring corona from Hinode/EIS
2014
In previous studies a very hot plasma component has been diagnosed in solar active regions through the images in three different narrow-band channels of SDO/AIA. This diagnostic from EUV imaging data has also been supported by the matching morphology of the emission in the hot Ca XVII line, as observed with Hinode/EIS. This evidence is debated because of unknown distribution of the emission measure along the line of sight. Here we investigate in detail the thermal distribution of one of such regions using EUV spectroscopic data. In an active region observed with SDO/AIA, Hinode/EIS and XRT, we select a subregion with a very hot plasma component and another cooler one for comparison. The ave…
High‐Resolution X‐Ray Spectroscopy of the Post–T Tauri Star PZ Telescopii
2004
We present an analysis of the Chandra High Energy Transmission Grating Spectrometer observation of the rapidly rotating P_(rot)=0.94 d post T Tauri (~20 Myr old) star PZ Telescopii, in the Tucana association. Using two different methods we have derived the coronal emission measure distribution, em(T), and chemical abundances. The em(T) peaks at log T = 6.9 and exhibits a significant emission measure at temperatures log T > 7. The coronal abundances are generally ~0.5 times the solar photospheric values that are presumed fairly representative of the composition of the underlying star. A minimum in abundance is seen at a first ionization potential (FIP) of 7-8 eV, with evidence for higher abu…
High Energy, High Resolution X-Ray Spectroscopy: Microcalorimeters For Nuclear Line Astrophysics
2005
We introduce focusing optics and microcalorimeter spectroscopy to nuclear line emission astrophysics with a balloon payload concept called, B‐MINE. It is designed to probe the deepest regions of a supernova explosion by detecting 44Ti emission at 68 keV with spatial and spectral resolutions that are sufficient to determine the velocity distribution of the 44Ti emitting region. B‐MINE has a thin plastic foil telescope multilayered to maximize the reflectivity in a 20 keV band centered at 68 keV and a microcalorimeter array optimized for the same energy band. This combination provides a reduced background, an energy resolution of 50 eV and a 3σ sensitivity in 106 s of 6 × 10−8 ph cm−2 s−1 at …
High-resolution study of some doubly excited vibrational states of PH2D: the m1 + m2, m2 + m5, m2 + m3, and m2 + m6 bands
2004
Abstract The absorption bands ν 1 + ν 2 , ν 2 + ν 3 , and ν 2 + ν 6 of PH 2 D have been recorded for the first time using a high-resolution Bruker 120 HR interferometer, and rotationally analyzed. Some transitions belonging to the very weak band ν 2 + ν 5 and enhanced in intensity by strong interactions with the ν 1 + ν 2 band were also assigned. Sets of parameters obtained from the fit reproduce experimental line position of the bands ν 1 + ν 2 and ν 2 + ν 3 with about the experimental accuracy. The residuals of the ro-vibrational energies of the ν 2 + ν 6 band are about 10 times larger. Reasons for the poorer reproduction of the latter data are given.
On coronal structures and their variability in active stars: The case of Capella observed with Chandra/LETGS
2003
In this paper we present a detailed analysis of two X-ray spectra of Capella, taken eleven months apart with the Low Energy Transmission Grating Spectrometer (LETGS) of the Chandra Observatory. We have studied variability of the coronal emission over different time scales, both in the whole X-ray band and in narrow temperature ranges identified by lines. The comparison of the two observations shows that the whole coronal emission of Capella in March 2000 was 3% higher than in February 2001; there also appears to be a tendency, albeit a marginal one, for the hottest lines to show the largest changes between the two observations. A detailed search for short-term variability (on time scales ra…