Search results for "Spectroscopy"
showing 10 items of 10293 documents
Development of a sensitive method for determining traces of prohibited acrylamide in cosmetic products based on dispersive liquid-liquid microextract…
2020
Abstract According to the European Regulation on cosmetic products, the presence of acrylamide in these consumer products is not allowed due to its mutagenic and potentially carcinogenic effects. Despite this ban, acrylamide might be present in those cosmetic products containing acrylamide-based polymers. However, there is no analytical method for its determination in this type of matrices. Based on this, the development of analytical methods for the determination of acrylamide in cosmetic products is required to guarantee consumer safety. In this work, an analytical method for determining traces of prohibited acrylamide in cosmetic products is presented for the first time. The method is ba…
Fourier transform infrared determination of Fluometuron in pesticide formulations
2003
Abstract A single method has been developed for Fourier transform infrared (FTIR) determination of Fluometuron in pesticide formulations. Samples were ultrasonically shaken with CHCl3 for 5 min and the FTIR spectra of sample extracts and standards were obtained at a nominal resolution of 4 cm−1 from 4000 to 900 cm−1 accumulating 25 scans. Fluometuron determination is based on the measure of peak area from 1342 to 1321 cm−1 corrected using a baseline defined from 1352 to 1294 cm−1. This procedure provided a limit of detection of 6.5 μg g−1, a sensitivity of 0.852 a.u. g mg−1 for a pathlength of 0.11 mm, a relative standard deviation of 1.6% for three analysis of a sample containing 50.4% (w/…
Selective determination of ammonium in water based on HPLC and chemiluminescence detection
2005
Abstract A selective and sensitive method has been developed for liquid chromatographic determination of ammonium in water samples. The analyte is derivatized with Dansyl Chloride prior to injection into HPLC. Optimal solution derivatization conditions have been established. The dansyl derivative is separated with the aid of a chromatographic column and post-column mixed with peroxyoxalate (TCPO) and H 2 O 2 in order to perform chemiluminescence detection. The detection limit achieved is 8 μg/L and linear response from 0.027 to 0.750 mg/L of ammonium was obtained. Ammonium ion was determined within 2.4 min under optimum chromatographic conditions. The method is fast, and near 10 derivatized…
Evaluation of working air quality by using semipermeable membrane devices
2008
Abstract It has been evaluated the use of semipermeable membrane devices (SPMDs) as passive samplers of organophosphorus pesticides from air, in order to determine the contamination of working environments. Additionally, the use of SPMDs as portable samplers has been also considered. The analytical methodology for the determination of diazinon, chlorpyrifos-methyl, pirimiphos-methyl, chlorpyrifos and fenthion in SPMDs exposed to contaminated air was based on microwave-assisted extraction and gas chromatography with mass spectrometry determination. Limit of detection (LOD) values from 2 to 4 ng SPMD−1 and repeatability from 2 to 7% were obtained by using the aforementioned methodology. Theor…
Improved detection limit for ammonium/ammonia achieved by Berthelot's reaction by use of solid-phase extraction coupled to diffuse reflectance spectr…
2005
Abstract The proposed procedure is based on the extraction of the indothylmol blue into C 18 solid-phase extraction (SPE) membranes and direct quantification on the membrane surface by diffuse reflectance spectroscopy. The analytical performance of the proposed method has been evaluated for standard solutions of ammonium using reflectance values, R , as well as the Kubelka–Munk function, F ( R ). The results have been compared with those obtained by the conventional method, which uses UV–vis absorption spectroscopy with a sensor-based method. The described methodology provided satisfactory linearity and reproducibility within the ammonium concentration intervals 25–250 μg L −1 and 25–500 μg…
On-line solvent recycling: a tool for the development of clean analytical chemistry in flow injection Fourier transform infrared spectrometry. Determ…
1998
Abstract A flow injection strategy has been developed for the direct determination of ketoprofen in pharmaceuticals by Fourier transform infrared spectrometry also incorporating a distillation unit which allows the carbon tetrachloride employed to dissolve samples and standards and used as a carrier to be recovered on-line. The system developed permits a drastic reduction of reagent consumption and easy and fast sampling and cleaning of the measurement cell. For the quantification of ketoprofen in pharmaceuticals the carbonyl bands at 1712 and 1666 cm −1 were employed and the developed method provided a 3 σ limit of detection of 0.04 mg ml −1 , a dynamic range up to 10 mg ml −1 and typical …
Chromium speciation using activated alumina microcolumns and sequential injection analysis-flame atomic absorption spectrometry
2001
Abstract A new procedure has been developed for chromium speciation in water by sequential injection analysis and flame atomic absorption spectrometry. The method involves the online retention of Cr(VI) anionic species and Cr(III) cationic species on alumina microcolumns, prepared by packing activated alumina in polytetrafluoroethylene tubes, followed by selective elution of Cr(VI) with 2 mol l −1 NH 4 OH and of Cr(III) with 0.2 mol l −1 HNO 3 . Studies were carried out on the effect of retention and elution conditions for both Cr species. The limit of detection values, established as the concentration corresponding to three times the standard deviation of blank measurements divided by the …
Univariate near infrared methods for determination of pesticides in agrochemicals
2006
Abstract It has been developed a general strategy for the determination of pesticides in agrochemicals by Fourier transform near infrared (FT-NIR) spectroscopy. The methodology is based on previous extraction of the active principles through sonication with acetonitrile and direct determination by transmission measurements, using glass vials as measurement cells and univariate calibration at selected wavenumbers as a function of the pesticide to be analyzed. Chlorsulfuron, metamitron, iprodione, pirimicarb, procymidone and tricyclazole were used as test molecules and data obtained by FT-NIR for 20 samples containing one of these active principles compare well with those found by reference l…
Determination of cyromazine in pesticide commercial formulations by vibrational spectrometric procedures
2004
Two vibrational spectrometry-based methodologies were developed for Cyromazine determination in solid pesticide formulations: a Fourier transform infrared (FTIR) procedure, based on the extraction of Cyromazine by CH3OH and direct determination in the extracts by peak height measurement at 1622 cm−1 corrected using a baseline defined at 1900 cm−1, and a FT-Raman determination, made directly on the powdered solid products using standard chromatographic glass vials as sample cells and measuring the Raman intensity between 633 and 623 cm−1 for a baseline established between 663 and 601 cm−1. The sensitivity obtained was 0.01631 absorbance g−1 mg for FTIR determination and 2.23 area values g−1 …
Direct injection of edible oils as microemulsions in a micellar mobile phase applied to the liquid chromatographic determination of synthetic antioxi…
1999
Abstract A simple and quick procedure for analysis of hydrophobic samples by direct injection in a liquid chromatograph, without previous extraction, has been developed. The sample is solved in a water/sodium dodecyl sulphate/n-pentanol microemulsion without destroying the microemulsion structure, and injected. A micellar mobile phase containing 0.1 M SDS, 2.5% n-propanol and 10 mM phosphate of pH 3 is used. The procedure is applied to the determination of synthetic antioxidants (propyl gallate, tert-butylhydroquinone, 2,4,5-trihydroxybutyrophenone, nordihydroguaiaretic acid, octyl gallate, 3-tert-butyl-4-hydroxyanisole and dodecyl gallate) in sunflower, corn and olive oils. Linear calibrat…