Search results for "Spectroscopy"
showing 10 items of 10293 documents
Analytical potential of mid-infrared detection in capillary electrophoresis and liquid chromatography: a review.
2010
Literature published in the last decade concerning the use of mid-infrared spectrometry as a detection system in separation techniques employing a liquid mobile phase is reviewed. In addition to the continued use of isocratic liquid chromatographic (LC) techniques, advances in chemometric data evaluation techniques now allow the use of gradient techniques on a routine basis, thus significantly broadening the range of possible applications of LC-IR. The general trend towards miniaturized separation systems was also followed for mid-IR detection where two key developments are of special importance. Firstly, concerning on-line detection the advent of micro-fabricated flow-cells with inner volu…
Determination of the Herbicide Fluometuron by Photo‐induced Chemiluminescence in a Continuous‐flow Multicommutation Assembly
2007
Abstract This study was dealing with the chemiluminometric determination of the selective herbicide Fluometuron or 1,1‐dimethyl‐3‐(α,α,α‐trifluoro‐m‐tolyl)urea, (C10H11F3N2O) with a molecular weight 232.29 belongs to the phenyl urea herbicides family. The analytical strategy is based on the continuous‐flow manifold, multicommutation and the analyte pre‐treatment, the photo‐degradation. The optimization of chemical (pH, medium, temperature, and organized media) and hydrodynamic parameters (volume of reagents and flow rate) was performed by univariant and multiparametric simplex procedure respectively. Analytical figures of merit and the effect of foreign substances were studied. The method r…
Enhancement of retention predictions in reversed-phase liquid chromatography using reference compounds
2004
Abstract The use of reference compounds to correct errors associated with the preparation of mobile phase is studied, in order to enhance modelling of retention for optimisation purposes in reversed-phase liquid chromatography. The method fits individual retention models for a set of reference compounds, which are present in all injections. In second step, mobile-phase composition is corrected for each chromatogram, according to the fitted models of the reference compounds. The enhanced precision provided by the large number of replicates for the reference compounds is partially propagated to the retention models of the analytes. The approach is assayed in the separation of amino acids, aft…
Chemometric determination of lipidic parameters in serum using ATR measurements of dry films of solvent extracts
2013
Attenuated total reflectance (ATR) infrared spectroscopy of dried organic extracts of serum samples has been evaluated as a fast method for the determination of triglycerides, cholesterol, high density lipoprotein (HDL) and low density lipoprotein (LDL). After careful selection of solvents based on green parameters, serum samples were extracted using hexane-isopropanol and ethyl acetate-ethanol mixtures. Microscopy studies and comparison with standard spectra were performed in order to investigate whether the proposed methodology is suitable for the quantification of lipids in serum samples. The results of these preliminary studies confirmed that the variations in the IR spectra of sample e…
Capillary electrokinetic fractionation mass spectrometry (CEkF/MS): Technology setup and application to metabolite fractionation from complex samples…
2014
Capillary electrokinetic fractionation (CEkF) is investigated as a new, simple, and robust approach for semipreparative and analytical sample analysis based on pKa -dependant pH-driven electrophoretic mobility. CEkF was optimized with contactless conductivity detection and conducted with 10 kV reverse voltage for 10 min, then coupled on/at-line to ESI/MS. We propose a semi-empirical model with 14 representative compounds based on the correlation between sample/medium pH regulating the partial charge, the electrokinetic loading of the capillary and intensity (I) of analytes. According to the model, an empirical function (I = f (pH)) could be derived to calculate the acid dissociation constan…
Preconcentration of aluminium by micellar-enhanced ultrafiltration
1993
Abstract Traces of aluminium were preconcentrated in water samples by forming a complex with lumogallion, and successfully accumulated in the micellar phase obtained from cationic or non-ionic surfactants and filtered through 10 000 molecular weight cut-off ultrafiltration membranes. Studies indicated that, at pH 5.9, with 1 X 10 −3 M lumogallion and 2 X 10 −2 M cetyltrimethylamonium bromide, quantitative retention of aluminium present at μg ml −1 concentration levels was achieved. A micellar-enhanced fluorimetric procedure was employed to analyse the permeate solutions, whereas nitrous oxide-acetylene flame atomic emission spectrometry was used to determine aluminium in the retentate. The …
Application of solid-phase microextraction combined with derivatization to the enantiomeric determination of amphetamines.
2005
Abstract The utility of combining chiral derivatization and solid-phase microextraction (SPME) for the enantiomeric analysis of primary amphetamines by liquid chromatography has been investigated. Different derivatization/extraction strategies have been evaluated and compared using the chiral reagent o -phthaldialdehyde (OPA)– N -acetyl- l -cysteine (NAC) and fibres with a Carbowax-templated resin coating. Amphetamine, norephedrine and 3,4-methylenedioxyamphetamine (MDA) were used as model compounds. On the basis of the results obtained, a new method is presented based on the derivatization of the analytes in solution followed by SPME of the OPA–NAC derivatives formed. The proposed conditio…
Materials and methods of signal enhancement for spectroscopic whole blood analysis: Novel research overview
2017
Abstract The early diagnosis of diseases is crucial for reducing morbidity and mortality and also for improving the quality of treatment process. Among various biological samples used to follow up the concentrations of disease markers, whole blood sensing can efficiently decrease analysis time by means of introducing methods with no pretreatment. In addition, the direct detection of markers in whole blood facilitates testing procedure and minimize the possibility of the loss of analytes in the process. Therefore, the assay of unprocessed whole blood is becoming increasingly important in clinical diagnostics and biomedical research. Incorporation of new advanced materials plays a major role …
First experimental proof of asymmetric charge transfer in ICP-MS/MS (ICP-QQQ-MS) through isotopically enriched oxygen as cell gas
2014
The quantification of a variety of elements in the field of ICP-MS is restricted by isobaric interferences. The recent development of ICP-MS/MS (“triple quadrupole” configuration) offers a new way to solve the problem of the detection of such elements affected by interferences because the signal caused by either the analyte or the isobaric interference can be shifted to another m/z through reactions with the cell gas (oxygen, ammonia or hydrogen). This system consists of two quadrupoles (Q1 and Q2) with a collision/reaction cell in between. When using the MS/MS mode of this configuration it becomes possible to restrict the ions entering the cell to a defined m/z and therefore get a better i…
Quantitative colorimetric analysis of some inorganic salts using digital photography
2011
An analytical imaging approach to the quantitation of dissolved chemical species absorbed in the visible spectral region is reported. The approach uses digital images of a series of standard solutions of the target substance and their processing with appropriate software to assign a numeric value to each standard in terms of color intensity. Such a value is directly proportional to the analyte concentration and allows the construction of a calibration graph. The results thus obtained are compared with those provided by the classical spectrophotometricmethod used to run calibration curves for colored substances. The chemical imaging technique is relative simple and affordable; in fact, it ca…