Search results for "Spherical equivalent"

showing 8 items of 18 documents

Determining postoperative anterior chamber depth

2003

Abstract Purpose: To compare measured and calculated postoperative anterior chamber depths (ACDs). Setting: Department of Ophthalmology and Institute of Medical Physics, University of Vienna, Vienna, Austria, and Department of Ophthalmology, University of Mainz, Mainz, Germany. Methods: The postoperative ACD was measured in 189 pseudophakic eyes using a laboratory prototype of partial coherence interferometry (PCI). In 6 intraocular lens (IOL) groups, the mean ACD was calculated by ray tracing based on the best-known A-constants of the SRK formulas. In addition, for each IOL type, each measured ACD was compared with a value calculated using the individual spherical equivalent of the postope…

medicine.medical_specialtyBiometryLightPseudophakiaAnterior Chambermedicine.medical_treatmentIntraocular lensSpherical equivalentLens Implantation IntraocularPower calculationsOphthalmologymedicineHumansPostoperative PeriodLenses Intraocularbusiness.industryModels TheoreticalCataract surgeryRefractionSensory SystemsOphthalmologyInterferometryPartial coherence interferometryConventional PCISurgerybusinessJournal of Cataract and Refractive Surgery
researchProduct

Heredity of interocular similarities in components of refraction: a population-based twin study among 66- to 79-year-old female twins.

2019

Purpose: To examine genetic influences on interocular similarities in ocular refraction and components of refraction among elderly female twins. Methods: Refraction was assessed in 94 monozygotic (MZ) and 74 dizygotic (DZ) female twins aged 66–78 years. Absolute values of interocular differences (Aniso variables) in spherical refraction (SR), refractive astigmatism (AST), spherical equivalent (SE), corneal refractive power (CR), corneal astigmatism (CAST), anterior chamber depth (ACD) and axial length (AL) were calculated. The differences between sisters in each of the Aniso variables were calculated and graded into two categories, best differentiating the groups, here isometropic and aniso…

medicine.medical_specialtyBiometryOLDER POPULATIONASTIGMATISMEmmetropiaBiologymedicine.disease_causeRefraction OcularCornea03 medical and health sciencesansiometropia0302 clinical medicineOphthalmologyHereditymedicineDiseases in TwinsTwins DizygoticHumansGenetic Predisposition to Disease3125 Otorhinolaryngology ophthalmology10. No inequalityAnisometropiaAgedspherical equivalentHERITABILITYisometropiaGeneral MedicineTwins MonozygoticHeritabilitymedicine.diseaseRefractive ErrorsTwin studyRefractionZygosityANISOMETROPIAPREVALENCEcorneal refractionOphthalmologyExact testastigmatism030221 ophthalmology & optometryRISK-FACTORSFemaleemmetropia030217 neurology & neurosurgeryActa ophthalmologica
researchProduct

Implantable collamer lens with central hole: 3-year follow-up.

2018

Luis Fernández-Vega-Cueto,1 Carlos Lisa,1 José J Esteve-Taboada,2 Robert Montés-Micó,2 José F Alfonso1,3 1Department of Surgery, Fernández-Vega Ophthalmological Institute, Oviedo, Spain; 2Department of Optics and Optometry and Visual Sciences, University of Valencia, Valencia, Spain; 3School of Medicine, University of Oviedo, Oviedo, Spain Purpose: To evaluate the long-term predictability, stability, safety, and efficacy of the V4c Visian implantable collamer lens (ICL) with central hole to correct myopia.Patients and methods: One hundred and eighty-four eyes of 92 patients were evaluated during 3 years after implantation of …

medicine.medical_specialtyDistance visual acuitygenetic structuresVisian ICLeducationEmmetropiaSpherical equivalentPhakic intraocular lensEndothelial cell count03 medical and health sciences0302 clinical medicineOphthalmologyMedicinehealth care economics and organizationsOriginal ResearchImplantable collamer lensbusiness.industryimplantable collamer lensClinical Ophthalmologyeye diseasesOphthalmologylong-term evaluation030221 ophthalmology & optometrybusinessphakic intraocular lens030217 neurology & neurosurgeryClinical ophthalmology (Auckland, N.Z.)
researchProduct

<p>Visual And Refractive Outcomes In Hyperopic Pseudophakic Patients Implanted With A Trifocal Intraocular Lens</p>

2019

Purpose To assess visual and refractive results after bilateral implantation of a trifocal intraocular lens (IOL) in patients with hyperopia. Methods In a retrospective nonrandomized study, 196 eyes of 98 patients had bilateral implantation of a trifocal IOL. The Barrett Universal II formula was used for IOL power calculation. Eyes were divided into two groups for their analysis: low-moderate, with IOL power ranging from 22 to 26 D, and high, with IOL power ranging from 25 to 34 D. Refractive error was used to assess predictability, and corrected distance visual acuity (CDVA) and uncorrected distance visual acuity values were used to assess efficacy and safety of the surgery. Results Six mo…

medicine.medical_specialtyRefractive errorDistance visual acuityVisual acuitygenetic structuresbusiness.industrymedicine.medical_treatmentSpherical equivalentIntraocular lensPhacoemulsificationmedicine.diseaseeye diseases03 medical and health sciencesOphthalmology0302 clinical medicineOphthalmology030221 ophthalmology & optometrymedicineIn patientsense organsmedicine.symptombusiness030217 neurology & neurosurgeryClinical Ophthalmology
researchProduct

Five-year change in refractive error and its risk factors: results from the Gutenberg Health Study.

2021

Background/AimsTo examine the 5-year change in refractive error in phakic eyes and its risk factors in the general population.MethodsThe Gutenberg Health Study (GHS) is a population-based cohort study including 15 010 participants from Germany aged 35–74 years at baseline examination (2007–2012). After 5 years, a follow-up examination was carried out (83% participation). 5-year change of spherical equivalent (SE) was computed as difference between follow-up and baseline objective refraction. Linear and logistic regression analysis were conducted analysing potential risk factors. Only phakic eyes at follow-up examination were included.ResultsRight eyes of 10 175 subjects were included. An ag…

medicine.medical_specialtyRefractive erroreducation.field_of_studybusiness.industryPublic healthPopulationFemale sexSpherical equivalentLogistic regressionmedicine.diseaseSensory SystemsCellular and Molecular NeuroscienceOphthalmologyEpidemiologyMedicinebusinesseducationCohort studyDemographyThe British journal of ophthalmology
researchProduct

Variations of OCT measurements corrected for the magnification effect according to axial length and refractive error in children

2018

Purpose: The aim of this paper was to examine the distribution of macular, retinal nerve fiber layer (RNFL) thickness and optic disc parameters of myopic and hyperopic eyes in comparison with emmetropic control eyes and to investigate their variation according to axial length (AL) and spherical equivalent (SE) in healthy children. Methods: This study included 293 pairs of eyes of 293 children (145 boys and 148 girls), ranging in age from 6 to 17 years. Subjects were divided according to SE in control (emmetropia, 99 children), myopia (100 children) and hyperopia (94 children) groups and according to axial AL in 68 short ([Formula: see text]22.00[Formula: see text]mm, 68), medium (from [For…

medicine.medical_specialtyRefractive errorgenetic structuresmagnification effectBiomedical EngineeringNerve fiber layerMedicine (miscellaneous)MagnificationEmmetropiaUlls -- Acomodació i refraccióSpherical equivalent:Ciències de la visió::Optometria::Acomodació i refracció [Àrees temàtiques de la UPC]lcsh:TechnologyEye--Accommodation and refractionLength measurement03 medical and health sciencesAxial length0302 clinical medicinechildrenOphthalmologyDegeneració retinalmedicinelcsh:QC350-467refractive errorRetinal degenerationOptical coherence tomographybusiness.industrylcsh:TMean ageAxial lengthmedicine.diseaseAtomic and Molecular Physics and Opticseye diseasesElectronic Optical and Magnetic Materialsmedicine.anatomical_structureCoherència (Òptica)OCT measurements030221 ophthalmology & optometryOptometrysense organsbusinessInfants030217 neurology & neurosurgerylcsh:Optics. LightOptic disc
researchProduct

Validity of automated refraction after segmented refractive multifocal intraocular lens implantation

2017

Aim To evaluate the clinical utility of automated refraction (AR) and keratometry (KR) compared with subjective or manifest refraction (MR) after cataract or refractive lens exchange surgery with implantation of Lentis Mplus X (Oculentis GmbH) refractive multifocal intraocular lens (IOL). Methods Eighty-six eyes implanted with the Lentis Mplus X multifocal IOL were included. MR was performed in all patients followed by three consecutive AR measurements using the Topcon KR-8000 autorefractor. Assessment of repeatability of consecutive AR before and after dilation with phenylephrine 10%, and comparison of the AR and KR with MR using vector analysis were performed at 3mo follow-up. Results Ana…

medicine.medical_specialtygenetic structuresSpherical equivalentMean differencelaw.invention03 medical and health sciences0302 clinical medicinelcsh:OphthalmologyClinical ResearchlawOphthalmologymedicineDioptreKeratometerbusiness.industry1733autorefractionvector analysisRepeatabilityMultifocal intraocular lensRefractioneye diseasesOphthalmologylcsh:RE1-994Autorefractor030221 ophthalmology & optometrymultifocal intraocular lensessense organsbusinessagreement030217 neurology & neurosurgeryInternational Journal of Ophthalmology
researchProduct

Ortokeratoloģijas ietekme uz acs garuma un refrakcijas izmaiņām bērniem ar miopiju

2017

Darbs uzrakstīts angļu valodā uz 68 lapaspusēm, satur 17 attēlus, 10 tabulas un 73 literatūras atsauces. Darba mērķis bija salīdzināt acu aksiālā garuma un refrakcijas izmaiņas divām grupām tuvredzīgo jauniešu. Vienai grupai tuvredzība tika koriģēta ar ortokeratoloģiskajām kontaktlēcām (OK), bet otrajai ar brillēm. Pēc 18 mēnešiem tuvredzīgo pacientu grupai koriģētai ar brillēm acs aksiālais garums vidēji palielinājās par 0,20 mm, turpretī pacientiem koriģētiem ar OK kontaktlēcām tas bija tikai 0,05 mm. Pacientu grupai koriģētai ar OK kontaktlēcām tuvredzības pieaugums vidēji bija tikai -0,04 D, bet pacientiem koriģētiem ar brillēm tas bija -0,40 D. Refrakcijas izmaiņu atšķirība 0,36 D bija…

myopic progressionrefraction spherical equivalentorthokeratologymyopiaOptometrijaeye axial length
researchProduct