Search results for "Stability."

showing 10 items of 3015 documents

Biomechanische Überlegungen über Stoßkräfte und Fußstabilität beim Laufen

1993

The interaction between "man-shoe and surface" is presented as a model to discuss the complexity of human locomotion. Only if the physiological system "man" interacts positively with the physical requirements of shoe and surface quality running will become effective and economical. Especially during the early ground contact phase the hardness of the shoe construction determines the height of the vertical impact load. These adaptations have consequences in the emg amplitudes during the stretch activation phase of the contact. Comparing various jogging shoes with altered construction properties it can be shown that the "hardness" of the shoe material is well adapted by the variation in the em…

musculoskeletal diseasesFoot (prosody)Computer sciencebusiness.industrytechnology industry and agricultureEMG amplitudeStructural engineeringFlexor musclesStability (probability)Biomechanical Phenomenabody regionsGround contactotorhinolaryngologic diseasesOrthopedics and Sports MedicineRange of motionbusinessHuman locomotionSportverletzung · Sportschaden
researchProduct

The craniovertebral junction in rheumatoid arthritis: State of the art

2019

Rheumatoid arthritis (RA) is a chronic inflammatory disorder, characterized by polyarticular inflammation causing progressive joint damage and disability. The mechanisms underlying its pathogenesis involve activation of innate and adaptive immunity, microvascular endothelial cell activation, and inflammatory infiltration of lymphocytes and monocytes into the synovium. Spinal involvement in RA is not typical; when it occurs, the main radiological features are (1) atlantoaxial subluxation (AAS), which is the most typical form of cervical spine involvement; (2) cranial settling—also known as basilar impression, atlantoaxial impaction or superior migration of the odontoid—which is the most seve…

musculoskeletal diseasesJoint InstabilityPathologymedicine.medical_specialtyBasilar invaginationTransoral decompressionInflammation030218 nuclear medicine & medical imagingPathogenesisArthritis Rheumatoid03 medical and health sciences0302 clinical medicineImmune systemSynovitisCervical spinemedicineRheumatoid arthritiTransnasal decompressionAtlantoaxial instabilitySubluxationInflammationSkull Basebusiness.industrySettore MED/27 - NeurochirurgiaInstrumentation and fusion procedureCraniovertebral junctionmedicine.diseaseAcquired immune systemAtlantoaxial dislocationAtlanto-Axial JointAtlantoaxial instabilityRheumatoid arthritisCervical Vertebraemedicine.symptombusinessAtlantoaxial synoviti030217 neurology & neurosurgeryHuman
researchProduct

Möglichkeiten der CT-Arthrographie in der Diagnostik von Schulterinstabilitäten

1990

In the course of a prospective study, CT arthrography was carried out on 40 patients with shoulder instability. In 35 of these patients a lesion of the capsule and labrum was demonstrated, indicating glenohumeral instability; in three patients this was shown primarily by CT arthrography. In three patients, multidirectional instability was demonstrated. In four patients there was an isolated lesion of the labrum, whereas in one patient all the findings were normal. Compared with the capsulo-labral lesions, bone changes involving the head of the humerus and the glenoid were of lesser importance, although their severity affected the choice of operative treatment in four patients. Fifteen of th…

musculoskeletal diseasesLabrummedicine.medical_specialtybusiness.industryGlenohumeral instabilityCapsuleSurgeryLesionmedicine.anatomical_structuremedicineMultidirectional instabilityRadiology Nuclear Medicine and imagingHumerusCt arthrographymedicine.symptombusinessNuclear medicineProspective cohort studyRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Preliminary Experience with a Novel System of Facet Fixation to Treat Patients with Lumbar Degenerative Disease. A New Perspective in Minimally Invas…

2017

Purpose We report our experience with a novel surgical device for the treatment of lumbar degenerative microinstability. Facet Wedge (DePuy Synthes, Raynham, Massachusetts, United States) is a novel technique of intra-articular lumbar facet fixation that provides a minimally invasive alternative to standard posterior fixation. Materials and Methods From November 2014 to July 2015, 38 patients underwent single-level Facet Wedge implantation. The main surgical indications included herniated disk (18 patients), spinal canal and foraminal stenosis (14 patients), and Meyerding grade I degenerative spondylolisthesis (6 patients). All the patients showed radiologic signs of microinstability: hype…

musculoskeletal diseasesMalemicroinstabilitymedicine.medical_specialtyfacet wedgedegenerative lumbar diseaseRadiographyIntervertebral Disc DegenerationZygapophyseal Joint03 medical and health sciencesFixation (surgical)0302 clinical medicineLumbarDegenerative diseasemedicineHumansMinimally Invasive Surgical ProceduresSpinal canal030212 general & internal medicineHerniated diskAgedLumbar Vertebraemedicine.diagnostic_testSettore MED/27 - Neurochirurgiabusiness.industryMagnetic resonance imagingMiddle Agedmedicine.diseaseOswestry Disability IndexSurgerymedicine.anatomical_structureSpinal FusionTreatment Outcomefacet fluid signalSurgeryFemaleNeurology (clinical)facet fusionSpondylolisthesisbusiness030217 neurology & neurosurgeryIntervertebral Disc DisplacementJournal of neurological surgery. Part A, Central European neurosurgery
researchProduct

Influence of the Screw Positioning on the Stability of Locking Plate for Proximal Tibial Fractures: A Numerical Approach

2020

Tibial fractures are common injuries in people. The proper treatment of these fractures is important in order to recover complete mobility. The aim of this work was to investigate if screw positioning in plates for proximal tibial fractures can affect the stability of the system, and if it can consequently influence the patient healing time. In fact, a more stable construct could allow the reduction of the non-weight-bearing period and consequently speed up the healing process. For that purpose, virtual models of fractured bone/plate assemblies were created, and numerical simulations were performed to evaluate the reaction forces and the maximum value of the contact pressure at the screw/bo…

musculoskeletal diseasesMaterials sciencemedicine.medical_treatmentHealing timelcsh:TechnologyStability (probability)Locking platelcsh:Chemistry03 medical and health sciences0302 clinical medicinemedicineCADGeneral Materials Science030212 general & internal medicineTibial fractureSettore ING-IND/15 - Disegno E Metodi Dell'Ingegneria Industrialelcsh:QH301-705.5InstrumentationReduction (orthopedic surgery)implant stabilityFluid Flow and Transfer ProcessesOrthodonticsFEM030222 orthopedicslcsh:TProcess Chemistry and TechnologyWork (physics)General Engineeringtibial fracturemusculoskeletal systemlocking plateslcsh:QC1-999Finite element methodComputer Science Applicationsreverse engineeringlcsh:Biology (General)lcsh:QD1-999lcsh:TA1-2040Proper treatmentlcsh:Engineering (General). Civil engineering (General)lcsh:PhysicsLocking plateApplied Sciences
researchProduct

Range of Motion and Injury Occurrence in Elite Spanish Soccer Academies. Not Only a Hamstring Shortening-Related Problem.

2020

Sanz, A, Pablos, C, Ballester, R, Sanchez-Alarcos, JV, and Huertas, F. Range of motion and injury occurrence in elite Spanish soccer academies. Not only a hamstring shortening-related problem. J Strength Cond Res 34(7): 1924-1932, 2020-Age-related development of range of motion (ROM) during an active hip flexion (active straight leg raise) and its relationship with hamstring injury occurrence were examined in 1657 young male soccer players (9-18 years of age). Age-related differences in ROM showed a significant decrease from U9 to U11 (p = 0.001), from U11 to U13 (p0.005), and from U9 to U13 (p0.001), whereas ROM increased from U13 to U15 and from U13 to U18 (both p's0.001). Interestingly, …

musculoskeletal diseasesStraight leg raiseMalemedicine.medical_specialtyWeaknessAdolescentJoint stabilityPoison controlPhysical Therapy Sports Therapy and RehabilitationHamstring Muscles030204 cardiovascular system & hematology03 medical and health sciences0302 clinical medicinePhysical medicine and rehabilitationInjury preventionSoccerMedicineHumansOrthopedics and Sports MedicineRange of Motion ArticularChildHamstring injurymedicine.diagnostic_testbusiness.industryYouth SportsAge Factors030229 sport sciencesGeneral Medicinemedicine.diseaseSpainmedicine.symptombusinessRange of motionhuman activitiesHamstringJournal of strength and conditioning research
researchProduct

Posterior Shoulder Instability

2020

Posterior shoulder instability is often hard to diagnose with clinical examination. Patients generally present with vague pain, weakness, and/or joint clicking but less frequently complaining of frank sensation of instability. Imaging examinations, especially MR imaging and magnetic resonance arthrography, have a pivotal role in the identification and management of this condition. This review describes the pathologic micro/macrotraumatic magnetic resonance features of posterior shoulder instability as well as the underlying joint abnormalities predisposing to this condition, including developmental anomalies of the glenoid fossa, humeral head, posterior labrum, and capsular and ligamentous …

musculoskeletal diseasesWeaknessLabrummedicine.diagnostic_testFossabiologybusiness.industryMagnetic resonance imagingPhysical examinationAnatomybiology.organism_classificationInstability030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineSensationmedicineRadiology Nuclear Medicine and imagingmedicine.symptombusinesshuman activitiesPosterior shoulder030217 neurology & neurosurgeryMagnetic Resonance Imaging Clinics of North America
researchProduct

Optimal positioning of the humeral component in the reverse shoulder prosthesis.

2014

Total reverse shoulder arthroplasty is becoming more and more the standard therapeutic practice for glenohumeral arthropathy with massive lesions of the rotator cuff. The biomechanical principle of this prosthesis is represented by the reversion of the normal anatomy of the shoulder joint. This non-anatomical prosthesis leads to a medialization of the rotation centre of the glenohumeral joint and also to a distalization of the humeral head. All that causes a deltoid tension increasing so allowing a larger abduction of the arm. Main complications of the reverse shoulder prosthesis are due to the joint instability, the scapular notching and the wear of the polyethylene insert. The main goal o…

musculoskeletal diseasesmedicine.medical_specialtyFEM analysesmedicine.medical_treatmentReplacementDeltoid curveProsthesis DesignProsthesisArthroplastyArthropathymedicineHumansOrthopedics and Sports MedicineHumerusRotator cuffArthroplasty ReplacementSettore ING-IND/15 - Disegno E Metodi Dell'Ingegneria IndustrialeTotal reverse shoulder arthroplasty Intrinsic stability FEM analyses Polyethylene wear Stability ratioFEM analyses; Intrinsic stability; Polyethylene wear; Stability ratio; Total reverse shoulder arthroplasty; Arthroplasty Replacement; Humans; Humerus; Prosthesis Design; Shoulder Joint; Orthopedics and Sports Medicine; Surgery; Medicine (all)business.industryShoulder JointMedicine (all)Intrinsic stabilityHumerusShoulder Prosthesismedicine.diseaseArthroplastySurgerymedicine.anatomical_structurePolyethylene wearStability ratioTotal reverse shoulder arthroplastySurgeryShoulder jointbusinesshuman activitiesMusculoskeletal surgery
researchProduct

MR-Tomographie versus CT-Arthrographie bei glenohumeralen Instabilitäten

1992

In a prospective study the diagnostic value of MRI compared to CT arthrography (CT-A) was evaluated in 26 patients with 27 instable shoulder joints. Surgical and/or arthroscopic correlation was available in all cases. Both methods showed a high accuracy (96% CT-A, 94% MRI) in the evaluation of the glenoid labrum. CT-A was significantly superior to MRI in the detection of capsular lesions (sensitivity 96% vs. 44%, accuracy 96% vs. 72%, negative predictive value 96% vs. 67%). CT-A and MRI results regarding humeral head fractures were similar; fractures of the glenoid rim were better detected by CT-A, the difference, however, was statistically not significant. Overall, CT-A proved to be superi…

musculoskeletal diseasesmedicine.medical_specialtyGlenoid labrumbusiness.industryGlenohumeral instabilityPredictive valueSurgerymedicine.anatomical_structureJoint capsuleMedicineUpper limbRadiology Nuclear Medicine and imagingCt arthrographyShoulder jointNuclear medicinebusinessProspective cohort studyRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Treatment of Combined Medial and Lateral Collateral Ligament Insufficiency

2016

The medial and lateral collateral ligament complexes represent primary elbow ligament stabilizers. Injury to these structures may occur because of an elbow dislocation or due to a severe varus or valgus force. Most elbow dislocations are stable once reduced and may be treated conservatively. However, if the elbow remains unstable surgical treatment is recommended. Repair should be anatomical and should restore stability to the elbow in order to permit an early active range of motion. Reconstruction may be required in severe cases and where primary repair is not possible. Depending on the degree of instability, either one or both of the collateral ligament complexes may need to be repaired o…

musculoskeletal diseasesmedicine.medical_specialtybiologybusiness.industryElbowmusculoskeletal systembiology.organism_classificationSurgerybody regionsValgusPrimary repairmedicine.anatomical_structureElbow dislocationelbow instability elbow ligament reconstruction circumferential graft reconstructionSettore MED/33 - Malattie Apparato LocomotoreLigamentMedicinebusinessSurgical treatmentRange of motion
researchProduct