Search results for "Standard"

showing 10 items of 3299 documents

Do ventilatory parameters influence outcome in patients with severe acute respiratory infection? Secondary analysis of an international, multicentre1…

2021

Purpose: To investigate the possible association between ventilatory settings on the first day of invasive mechanical ventilation (IMV) and mortality in patients admitted to the intensive care unit (ICU) with severe acute respiratory infection (SARI). Materials and methods: In this pre-planned sub-study of a prospective, multicentre observational study, 441 patients with SARI who received controlled IMV during the ICU stay were included in the analysis. Results: ICU and hospital mortality rates were 23.1 and 28.1%, respectively. In multivariable analysis, tidal volume and respiratory rate on the first day of IMV were not associated with an increased risk of death; however, higher driving pr…

ARDSSoins intensifs réanimationmedicine.medical_treatmentAirway pressuresPEEP positive end-expiratory pressureCritical Care and Intensive Care Medicinelaw.inventionHypoxemiaCohort StudiesPositive-Pressure RespirationMechanical ventilationSARI severe acute respiratory infectionlawHospital MortalityProspective StudiesIQR interquartile rangesProspective cohort studyRCT randomized controlled trialTidal volumeSOFA Sequential Organ Failure AssessmentSAPS Simplified Acute Physiology ScoreIntensive care unitVCV volume-controlled ventilationHIV human immunodeficiency virusIntensive Care UnitsIC GLOSSARI Intensive Care Global Study on Severe Acute Respiratory Infectionmedicine.symptomCohort studyLOS length of staymedicine.medical_specialtyVt tidal volumeCOPD Chronic obstructive pulmonary diseaseNYHA New York Heart Association.PCV pressure-controlled ventilationArticleInternal medicineICU Intensive Care UnitSIMV Synchronized intermittent mandatory ventilationmedicineTidal VolumeHumansDP driving pressurePEEPARDS acute respiratory distress syndromeMechanical ventilationbusiness.industryOdds ratioPneumoniaPlateau pressuremedicine.diseaseRespiration ArtificialVILI ventilator induced lung injuryCI confidence intervalOR odds ratioIMV invasive mechanical ventilationCPAP continuous positive airway pressureARDSbusinessSD standard deviationECMO extracorporeal membrane oxygenationPBW predicted body weightPplat plateau pressure
researchProduct

Systematic Study of Several Causes and Effects Due to Absorbent Blanks in Determinations of One Analyte

1999

A systematic study is performed about several factors involved in the measurements when a absorbent blank is used, as molar absorption coefficient of the formed complex, absorbance of the blank at the measured wavelength, and kind of spectrophotometer used (conventional double-beam or diode-array). It is proved that the usual methodology, measuring against reagent blank, produces less accurate measurements than those obtained against solvent blank. On the other hand, use of the H-Point standard additions method provides always equal or better results than the best ones obtained at single wavelengths by using measurements against solvent bank, at the maximum of the formed complex. To test th…

AbsorbanceAnalyteChemistryReagentStandard additionAnalytical chemistryCalibrationArsenazo IIIMolar absorptivityBlankAnalytical ChemistryMicrochimica Acta
researchProduct

Solid sampling Fourier transform infrared determination of Mancozeb in pesticide formulations

2004

Abstract A series of approaches have been assayed for FTIR determination of Mancozeb in several solid commercial fungicides using different calibration strategies. The simplest procedure was based on the use of the ratio between the absorbance of a characteristic band of Mancozeb and that of a KSCN internal standard measured in the FTIR spectra obtained from KBr pellets. It was employed the quotient between peak height absorbance values at 1525 cm−1 for Mancozeb and 2070 cm−1 for KSCN. In these conditions a precision as relative standard deviation (RSD) of 0.6% and a relative accuracy error of 0.8% (w/w) were found. For complex formulations, containing other compounds with characteristic ab…

AbsorbanceChemistryStandard additionPartial least squares regressionCalibrationAnalytical chemistryInfrared spectroscopyMancozebFourier transform spectroscopyStandard deviationAnalytical ChemistryTalanta
researchProduct

Creatinine determination in urine samples by batchwise kinetic procedure and flow injection analysis using the Jaffé reaction: chemometric study

2001

The classical Jaffé reaction for the determination of creatinine in urine samples is tested. A comparative study of the main analytical characteristics focussed to minimize the bias error and improve the precision, for the batchwise and flow injection (FI) methods is realized. Also, the effect of the albumin concentration in the determination of creatinine has been studied. Different analytical signals were studied. Absorbance increments at different times permit to estimate the creatinine concentration free from bias error in urine by the batchwise method using the calibration graph obtained with creatinine standards and no measurement of the blank solution is needed. The lineal interval w…

AbsorbanceFlow injection analysisCreatininechemistry.chemical_compoundChromatographychemistryCalibration curveStandard additionCalibrationAnalytical chemistryUrineQuantitative analysis (chemistry)Analytical ChemistryTalanta
researchProduct

Effect of cooking on oxalate content of pulses using an enzymatic procedure.

2003

An enzymatic method proposed for the determination of oxalate in urine is adapted for the estimation of soluble oxalate content in beans, chickpeas and lentils. Oxalates were extracted in water by refluxing for 2 h. The method is based on the oxidation of oxalate by the oxidase and the determination of the resulting hydrogen peroxide, which in presence of peroxidase, 3-methyl-2 benzotiazinolone and 3-dimethylamino benzoic, gives an indamine compound with an absorption maximum at 590 nm. The linearity (from 0.015 to 0.6 mM) of the method is adequate to the analysis of oxalate contents in pulses, and the inter-day precision of the method expressed as relative standard deviation was good (3.01…

Absorption (pharmacology)chemistry.chemical_classificationOxalatesChromatographyHot TemperaturebiologyChemistryFood HandlingInorganic chemistryRelative standard deviationFabaceaeSoluble oxalateOxalateFood handlingchemistry.chemical_compoundEnzymebiology.proteinHydrogen peroxideMicrowavesNutritive ValueFood SciencePeroxidaseInternational journal of food sciences and nutrition
researchProduct

gNOMO: a multi-omics pipeline for integrated host and microbiome analysis of non-model organisms

2020

The study of bacterial symbioses has grown exponentially in the recent past. However, existing bioinformatic workflows of microbiome data analysis do commonly not integrate multiple meta-omics levels and are mainly geared toward human microbiomes. Microbiota are better understood when analyzed in their biological context; that is together with their host or environment. Nevertheless, this is a limitation when studying non-model organisms mainly due to the lack of well-annotated sequence references. Here, we present gNOMO, a bioinformatic pipeline that is specifically designed to process and analyze non-model organism samples of up to three meta-omics levels: metagenomics, metatranscriptomic…

AcademicSubjects/SCI01140AcademicSubjects/SCI01060DATABASEComputer scienceAcademicSubjects/SCI00030Context (language use)Standard ArticleComputational biologycomputer.software_genreAcademicSubjects/SCI0118003 medical and health sciences0302 clinical medicineMedicine and Health SciencesMicrobiomeOrganism030304 developmental biology0303 health sciencesCHALLENGESSTABILITYGUT MICROBIOTABiology and Life SciencesPipeline (software)WorkflowPERSPECTIVESMetagenomicsMetaproteomicsAcademicSubjects/SCI00980METAPROTEOMICSCorrigendumcomputer030217 neurology & neurosurgeryData integrationNAR Genomics and Bioinformatics
researchProduct

An in-depth evaluation of acalabrutinib for the treatment of mantle-cell lymphoma

2020

Introduction: Regimens involving intensive immuno-chemotherapy, followed by high-dose therapy and autologous stem cell transplant represent the standard treatment for younger fit patients with mantle cell lymphoma (MCL). Targeted approaches (i.e. ibrutinib, bortezomib, and lenalidomide) represent the backbone of therapy for relapsed cases. Areas covered: Acalabrutinib is a novel small molecule with a butynamide moiety specifically designed to irreversibly inhibit Bruton tyrosine kinase (BTK), which is more potent and selective than ibrutinib. Relevant publications have been identified through literature searches using the terms 'mantle cell lymphoma' and 'acalabrutinib'. Expert opinion: Aca…

Acalabrutinib; BTK; MCL; therapy; Agammaglobulinaemia Tyrosine Kinase; Antineoplastic Agents; Antineoplastic Combined Chemotherapy Protocols; Benzamides; Humans; Lymphoma Mantle-Cell; Protein Kinase Inhibitors; PyrazinesOncologymedicine.medical_specialtyLymphomaAntineoplastic AgentsLymphoma Mantle-Cell03 medical and health scienceschemistry.chemical_compound0302 clinical medicineimmune system diseaseshemic and lymphatic diseasesInternal medicineAntineoplastic Combined Chemotherapy ProtocolsAgammaglobulinaemia Tyrosine KinaseHumansMedicineBruton's tyrosine kinasePharmacology (medical)Protein Kinase InhibitorsLenalidomidePharmacologytherapy.therapybiologyAcalabrutinibbusiness.industryBortezomibStandard treatmentMCLGeneral MedicineMantle-Cellmedicine.diseaseClinical trialchemistryBTKPyrazines030220 oncology & carcinogenesisIbrutinibBenzamidesbiology.proteinAcalabrutinibMantle cell lymphomabusiness030217 neurology & neurosurgerymedicine.drugExpert Opinion on Pharmacotherapy
researchProduct

Scientific Merits and Analytical Challenges of Tree‐Ring Densitometry

2019

X-ray microdensitometry on annually resolved tree-ring samples has gained an exceptional position in last-millennium paleoclimatology through the maximum latewood density (MXD) parameter, but also increasingly through other density parameters. For 50 years, X-ray based measurement techniques have been the de facto standard. However, studies report offsets in the mean levels for MXD measurements derived from different laboratories, indicating challenges of accuracy and precision. Moreover, reflected visible light-based techniques are becoming increasingly popular, and wood anatomical techniques are emerging as a potentially powerful pathway to extract density information at the highest resol…

Accuracy and precision010504 meteorology & atmospheric sciencesComputer scienceResolution (electron density)X ray densitometry010502 geochemistry & geophysicscomputer.software_genre01 natural sciencesGeophysics13. Climate actionRelevance (information retrieval)Data miningcomputer0105 earth and related environmental sciencesDe facto standardReviews of Geophysics
researchProduct

Determination of one compound in the presence of a single interference. Linear absorbances method

1992

The paper exposes the theoretical and experimental principles of an analytical procedure for the determination of one compound in the presence of another with an overlapping absorption spectrum, without the need to use any standard solutions of the latter. The proposed method was applied to the determination of binary mixtures of known composition in order to assess its accuracy and precision.

Accuracy and precisionAbsorption spectroscopyChemistryAnalytical chemistryBinary numberStandard solutionInterference (wave propagation)BiochemistryAnalytical ChemistryFresenius' Journal of Analytical Chemistry
researchProduct

Comparison of novel and conventional calibration techniques for the analysis of urine samples using plasma source mass spectrometry combined with a n…

2012

The accuracy and precision of the analytical data from the analysis of liquid samples with high matrix load often suffer from a compromised performance of the sample introduction system. This is especially significant in the case of miniaturized, pneumatic low flow nebulizers. Alternative low-flow sampling devices based on different operating principles are imperative to overcome this drawback. The superior performance of such an alternative liquid sample introduction system for ICP-MS, the drop-on-demand (DOD) aerosol generator based on thermal inkjet technology, was recently outlined by the same group for the analysis of aqueous standard solutions. Current improvements of the system now a…

Accuracy and precisionChemistrybusiness.industryPlasma source mass spectrometryDrop (liquid)NozzleAnalytical chemistryStandard solutionAnalytical ChemistryMatrix (chemical analysis)Aerosol generatorOn demandProcess engineeringbusinessSpectroscopyJournal of Analytical Atomic Spectrometry
researchProduct