Search results for "Stent-graft"

showing 10 items of 22 documents

CT Angiography at 24 Months Demonstrates Durability of EVAR With the Use of Chimney Grafts for Pararenal Aortic Pathologies

2013

PURPOSE: To present the 24-month radiological follow-up data for patients with pararenal aortic pathologies treated with chimney and periscope grafts during endovascular repair. METHODS: Between January 2008 and December 2011, 124 high-risk patients with complex pararenal aortic pathologies were treated using the chimney technique at 2 European vascular and cardiovascular centers with advanced experience of the described technique. In particular, 50 patients were treated at Site 1 and 74 at Site 2. Forty (32.2%) patients (32 men; mean age 79.2±4.9 years) completed computed tomographic angiography follow-up at 24 months postoperatively. RESULTS: The overall technical success was 100%, and th…

Malemedicine.medical_specialtyTime Factorsmedicine.medical_treatmentAortic Diseases610 Medicine & healthEndovascular aneurysm repair2705 Cardiology and Cardiovascular MedicineAortic aneurysmAneurysmmedicine.arterymedicineHumans2741 Radiology Nuclear Medicine and ImagingRadiology Nuclear Medicine and imagingAorta AbdominalEmbolizationSuperior mesenteric arteryAgedendovascular aneurysm repair chimney graft periscope graft pararenal aortic pathologies aortic aneurysm para-anastomotic aneurysm ruptured aneurysm stent-graft balloon-expandable stent-graft computed tomographic angiography endoleak renal arteries superior mesenteric artery sac shrinkage sac expansionmedicine.diagnostic_test10042 Clinic for Diagnostic and Interventional Radiologybusiness.industryEndovascular ProceduresAngiographyPerioperativemedicine.diseaseBlood Vessel Prosthesis10020 Clinic for Cardiac Surgery2746 SurgerySurgeryCuffAngiographyFemaleStentsSurgeryRadiologyTomography X-Ray ComputedCardiology and Cardiovascular MedicinebusinessFollow-Up StudiesJournal of Endovascular Therapy
researchProduct

Chimney endografting for pararenal aortic pathologies using transfemoral access and the lift technique

2013

Purpose: To present a technique for transfemoral implantation of parallel grafts into the renal arteries in patients with anatomy or morphology that blocks standard antegrade chimney graft delivery. Technique: In a totally percutaneous approach, a 5-F pigtail angiographic catheter is passed into the aorta above the renal arteries via a 0.035-inch hydrophilic guidewire, followed by an 8-F sheath. The target vessel is cannulated with the hydrophilic wire followed by a 5-F reverse curve catheter; the wire is changed for a Rosen wire. The main stent-graft body is delivered and parked at the level of the aortic bifurcation. The Viabahn chimney endograft is advanced ~1 to 2 cm into the target ren…

Settore MED/22 - Chirurgia Vascolareendovascular repair abdominal aorta pararenal aorta aneurysm endovascular aneurysm repair stent-graft chimney graft chimney technique deployment technique self-expanding stent-graft
researchProduct

Chimney and Periscope Grafts Observed Over 2 Years After Their Use to Revascularize 169 Renovisceral Branches in 77 Patients With Complex Aortic Aneu…

2013

Purpose: To evaluate the performance of periscope and/or chimney grafts (CPGs) in the endovascular treatment of pararenal or thoracoabdominal aneurysms using off-the-shelf devices. Methods: Between February 2002 and August 2012, 77 consecutive patients (62 men; mean age 7369 years) suffering from pararenal aortic (n¼55), thoracoabdominal (n¼16), or arch to visceral artery aneurysms (n¼6) were treated with aortic stent-graft implantation requiring chimney and/or periscope grafts to maintain side branch perfusion. CPGs were planned in advance and were not used as bailout. A standardized follow-up protocol including computed tomographic angiography, laboratory testing, and clinical examination…

aortic aneurysm pararenal aortic aneurysm thoracoabdominal aortic aneurysm aortic arch endovascular aneurysm repair renal artery superficial mesenteric artery celiac trunk target vessel stent-graft side branch chimney graft periscope graft parallel graft target vessel patency endoleak side branch occlusionSettore MED/22 - Chirurgia Vascolare
researchProduct

Endovascular Treatment of Spontaneous and Isolated Infrarenal Acute Aortic Syndrome with Unibody Aortic Stent-Grafts

2020

Abstract Introduction Spontaneous acute aortic syndrome (IAAS) is rarely localized in the infrarenal aorta. The endovascular approach is preferred over conventional open surgery with fewer complications. However, dedicated endovascular devices for IAAS treatment are unavailable. The aim was to report a large single-center experience using unibody stent-grafts to address IAAS. Methods From April 2016 to March 2019, a retrospective analysis of patients presenting spontaneous and isolated IAAS was performed. Patients addressed with the unibody stent-graft (AFX endovascular AAA system; Endologix Inc., Irvine, CA) were included in the study. Indications to IAAS treatment were persistent symptoms…

medicine.medical_specialtyOriginal Scientific Report030204 cardiovascular system & hematologyProsthesis DesignSettore MED/22 - Chirurgia VascolareInfrarenal acute aortic syndromeunibody stent-graftBlood Vessel Prosthesis Implantation03 medical and health sciencesAortic aneurysm0302 clinical medicineintramural hematoma.Blood vessel prosthesismedicine.arterymedicineHumansaortic dissection penetrating aortic ulcercardiovascular diseasesAorta Abdominal030212 general & internal medicineRetrospective StudiesAcute aortic syndromebusiness.industryEndovascular ProceduresAbdominal aortaVascular surgerymedicine.diseaseBlood Vessel ProsthesisSurgeryStenosissurgical procedures operativeTreatment OutcomeCardiothoracic surgeryendovascularStentsSurgerybusinessAortic Aneurysm AbdominalAbdominal surgeryWorld Journal of Surgery
researchProduct

Classification of Chimney EVAR-Related Endoleaks: Insights from the PERICLES Registry

2017

Juxtarenal aortic aneurysms (JAAs) pose significant challenges for endovascular aneurysm repair (EVAR). A short or absent infrarenal neck typically excludes standard EVAR as a viable or reasonable treatment option. In this context, the use of chimney grafts (chEVAR) is gaining in popularity and applicability. These grafts are designed to course in the aortic lumen outside the main stent-graft to maintain normal perfusion to the involved target branches. As such, they may represent a promising and less resource-intensive option for management of JAAs. However, this technical strategy is not without challenges of its own, particularly the inevitable creation of “gutters” that result from the …

medicine.medical_specialtyRadiology Nuclear Medicine and Imagingabdominal aortic aneurysm; chimney graft; chimney technique; endograft; endoleak; stent-graftendoleak610 Medicine & health030204 cardiovascular system & hematologySettore MED/22 - Chirurgia Vascolare2705 Cardiology and Cardiovascular Medicine03 medical and health sciences0302 clinical medicineabdominal aortic aneurysmchimney techniqueNuclear Medicine and Imagingmedicine2741 Radiology Nuclear Medicine and ImagingChimney030212 general & internal medicinestent-graftbusiness.industryChimney graftchimney graftendograftmedicine.diseaseAbdominal aortic aneurysmSurgery10020 Clinic for Cardiac Surgery2746 SurgerygraftSurgerystentRadiologybusinessCardiology and Cardiovascular Medicineabdominal aortic aneurysm; chimney graft; chimney technique; endograft; endoleak; stent-graft; Radiology Nuclear Medicine and Imaging; Cardiology and Cardiovascular Medicine
researchProduct

Iliac-femoral stent-graft infection after hybrid procedure redo: Case report

2021

Introduction Stent-graft infection in peripheral arteries is rare and potentially dangerous. The use of hybrid procedures, in complicated patients previously treated, involves an increase of infective risk especially in no collaborative patients. Presentation of case We report a case of rare stent-graft infection in a patient treated for a Rutherford IV Multiple Peripheral Arterial Disease (MPAD) involving the right iliac-femoral axis with stenosis on deep femoral artery due to a previously stenting procedure for Superficial Femoral artery (SFA) stenosis. The first simultaneous hybrid intervention consisted of an endovascular iliac stent-graft placement and a surgical common femoral patch a…

medicine.medical_specialtySuperficial femoral arterymedicine.medical_treatmentIschemiaCase ReportSettore MED/22 - Chirurgia Vascolare03 medical and health sciences0302 clinical medicinemedicine.arterymedicineDeep Femoral ArteryStent-graftcardiovascular diseasesEndovascularbusiness.industryStentmedicine.diseaseCommon iliac arterySurgeryCommon iliac arteryStenosissurgical procedures operativeAmputation030220 oncology & carcinogenesis030211 gastroenterology & hepatologySurgeryPresentation (obstetrics)InfectionComplicationbusinessInternational Journal of Surgery Case Reports
researchProduct

Computational Fluid Dynamics (CFD) and Finite Element Analysis (FEM) of a Customized Stent-Graft for Endovascular (EVAR) Treatment of Abdominal Aorti…

2023

Background: The treatment of abdominal aortic aneurysm (AAA) is today commonly treated by inserting a stent-graft by the endovascular route, without resorting to open surgery. However, some clinical cases do not allow this less invasive approach, meaning that the stent-graft cannot be inserted and open surgery is used. Methods: In the study, we propose a fluid–structure interaction (FSI) analysis of an aneurysmatic aorta that could not be treated with Endovascular Aneurysm Repair (EVAR). The vessel is reconstructed through segmentation from CT scans and subsequently modeled on CAD software to create the surface and thickness of the vessel itself. Subsequently, we proceeded to carry out Comp…

patient specificFluid Flow and Transfer ProcessesProcess Chemistry and TechnologyGeneral Engineeringstent-graft; patient specific; Computational Fluid Dynamics; finite element analysisGeneral Materials ScienceStent-graftfinite element analysisComputational Fluid DynamicSettore ICAR/08 - Scienza Delle CostruzioniInstrumentationfinite element analysiComputer Science ApplicationsApplied Sciences
researchProduct

Endoluminal stent-graft relining of visceral artery bypass grafts to treat perigraft seroma.

2013

Purpose: To describe the endovascular treatment of intra-abdominal perigraft seromas associated with small-caliber expanded polytetrafluoroethylene (ePTFE) grafts. Case Reports: Two patients who underwent hybrid repair of thoracoabdominal aortic aneurysms in which renovisceral bypass grafts were implanted presented with large, symptomatic perigraft seromas. The 5- to 8-mm-diameter ePTFE bypass grafts believed to be involved in the seromas were successfully relined with self-expanding Viabahn stentgrafts in percutaneous procedures. The patients’ symptoms were relieved, and imaging follow-up (18 and 10 months, respectively) has shown near complete resorption of the seromas. Conclusion: It is …

seroma stent-graft prosthetic graft graft relining endovascular repair polytetrafluoroethylene graft vascular graft bypass surgerySettore MED/22 - Chirurgia Vascolare
researchProduct

Wewnątrznaczyniowe dwuetapowe leczenie tętniaków aorty brzusznej z użyciem Heli-FX EndoAnchor System

2019

Wstęp: Wyniki leczenia tętniaków aorty brzusznej mimo wprowadzenia nowych technik wewnątrznaczyniowych nadal nie zawsze są zadowalające. Szczególnie trudną grupą pacjentów są osoby z krótką oraz stożkową szyją. W tej grupie chorych często występuje w okresie pooperacyjnym przeciek typu I. Jedną z metod mających temu powikłaniu zapobiec jest zastosowanie wkrętów wewnątrznaczyniowych Heli-FX. Ma to zwiększyć przyleganie systemu stentgraftu do ściany aorty brzusznej oraz zapobiec jego ewentualnej migracji. Materiał i metody: Autorzy niniejszego artykułu proponują zastosowanie leczenia dwuetapowego. Pierwszy etap stanowiła implantacja przedłużki aortalnej tuż poniżej odejścia tętnic nerkowych i…

stent-grafttętniak aorty brzusznejendoanchorstrudna szyja tętniakaendovascular proceduresstentgraft aortalnywkręty wewnątrznaczynioweaortic aneurysmhostile neckendovascular aortic repairChirurgia Polska
researchProduct

Periscope endograft technique to revascularize the left subclavian artery during thoracic endovascular aortic repair.

2013

Purpose: To present early and midterm results of the periscope endograft (PG) technique to maintain left subclavian artery (LSA) blood flow in thoracic endovascular aortic repairs (TEVAR) involving zone 3. Methods: From April 2010 to January 2013, 14 consecutive high-risk patients (11 men; mean age 7068 years, range 56–87) underwent TEVAR with the PG technique for 10 thoracic aortic aneurysms (TAA), 2 traumatic aortic ruptures, and 2 aortic dissections without a suitable landing zone (.2 cm distal to the LSA). Five procedures were performed emergently for rupture (3 TAAs and the 2 trauma cases). Two patients had a periscope deployed in an aberrant right subclavian artery. The periscope endo…

thoracic aorta thoracic aortic aneurysm dissection arch aneurysm thoracic endovascular aortic repair stent-graft left subclavian artery periscope graft deployment technique proximal landing zoneSettore MED/22 - Chirurgia Vascolare
researchProduct