Search results for "Stent"
showing 10 items of 1166 documents
Endovascular treatment options for complex abdominal aortic aneurysms
2015
Abstract Purpose To report short-term and midterm outcomes of endovascular aneurysm repair (EVAR) of complex aneurysms requiring revascularization of visceral arteries. Materials and Methods Prospective data were collected from patients deemed unsuitable for conventional EVAR and conventional surgery who were treated with different endovascular approaches according to the clinical presentation of the aneurysm. Custom-made fenestrated endovascular aneurysm repair (CM f-EVAR) was used in the elective setting, homemade fenestrated endovascular aneurysm repair (HM f-EVAR) or HM f-EVAR combined with chimney endovascular aneurysm repair (ch-EVAR) was used in the emergent setting in patients with …
Late Complication after Superficial Femoral Artery (SFA) Aneurysm: Stent-graft Expulsion Outside the Skin.
2014
A 78-year-old man presented with a 7-cm aneurysm in the left superficial femoral artery, which was considered unfit and anatomically unsuitable for conven- tional open surgery for multiple comorbidities. The patient was treated with stent-graft [Viabhan stent-graft (WL Gore and Associates, Flagstaff, AZ)]. Two years from stent-graft implantation, the patient presented a purulent secretion and a spontaneous external expulsion through a fistulous channel. No claudication symptoms or hemorrhagic signs were present. The pus and device cultures were positive for Staphylococcus aureus sensitive to piperacillin/tazobac- tam. Patient management consisted of fistula drainage, systemic antibiotic the…
Three-Dimensional Analysis of Component Stability of the Nellix Endovascular Aneurysm Sealing System After Treatment of Infrarenal Abdominal Aortic A…
2016
Purpose: To assess short-term stability and conformational changes of the Nellix EndoVascular Aneurysm Sealing (EVAS) System using 3-dimensional (3D) analysis. Methods: Postoperative computed tomography (CT) scans obtained at 0, 3, and 12 months in 24 patients (mean age 75±7 years; 22 men) who underwent EVAS between December 2013 and December 2014 for intact abdominal aortic aneurysm (within the instructions for use) were evaluated for stent-graft deviation in multiple planes using dedicated 3D analysis software. In addition, 2D analysis using an anatomically fixed reference landmark was performed to assess craniocaudal migration. Clinical and follow-up data of the patients were recorded a…
Subclavian Stenosis/Occlusion in Patients with Subclavian Steal and Previous Bypass of Internal Mammary Interventricular Anterior Artery: Medical or …
2004
There are only a few published studies on the association between subclavian steal syndrome and ischemic heart disease. The objective of this report is to evaluate the efficacy of subclavian stenoocclusion treatment in patients with subclavian steal syndrome (SSS) and previous cor- onary bypass. Over the last 8 years we observed 207 patients who underwent left internal mammary artery–intraventricular artery (LIMA–IVA) bypass graft. Of these, 31 patients were affected by steno-occlusion of the homolateral subclavian artery. Ten patients (group 1) showed latent vertebral-SSS and were pharmacologically treated. Seven patients (group 2) had an intermittent vertebral-SSS; four patients were trea…
A Multicenter Experience With a New Fenestrated-Branched Device for Endovascular Repair of Thoracoabdominal Aortic Aneurysms.
2018
To investigate the outcomes of patients who were treated for thoracoabdominal aortic aneurysms (TAAAs) using custom-made fenestrated-branched stent-grafts.A consecutive series of 108 patients (mean age 73.5 years; 73 men) with TAAA were treated with E-xtra Design Engineering customized fenestrated-branched stent-grafts between November 2011 and January 2017. Data on baseline characteristics, procedures, and clinical follow-up were collected from 6 regional European surgical centers for retrospective analysis of endoleaks, reinterventions, and target vessel patency. The median aneurysm diameter was 6.75 cm (range 5.5-13). The distribution of the TAAA according to the modified Crawford classi…
Popliteal Artery Aneurysm Repair in the Endovascular Era: Fourteen-Years Single Center Experience
2015
Abstract To compare outcomes of popliteal artery aneurysm (PAA) repair by endovascular treatment, great saphenous vein (GSV) bypass, and prosthetic bypass. Single center retrospective analysis of patients presenting PAA from 2000 to 2013. Patients were divided into endovascular treatment (group A); GSV bypass (group B); and prosthetic graft bypass (group C). Outcomes were technical success, perioperative mortality, and morbidity. Survival, primary and secondary patency, and freedom from reintervention rate were estimated. Differences in ankle-brachial index (ABI), in-hospital length of stay (InH-Los), red blood cell (RBC) transfusion, and limb loss were reported. Mean follow-up was 49 (medi…
Repair of TEVAR-Associated Type A Dissection in the Elderly Is Possible With Reasonable Morbidity and Mortality.
2018
Background: Type A aortic dissection (AAD) is a devastating complication of thoracic endovascular repair (TEVAR). In elderly patients, surgery for AAD carries considerable morbidity and mortality. Repair of AAD after previous TEVAR is an even greater challenge as it usually requires the arch to be addressed and a preexisting stent graft to be included into the aortic repair. Methods: A case series of 5 elderly patients who presented with acute AAD after previous TEVAR was reviewed. In 4 cases, there was retrograde AAD with involvement of the arch and stent graft. In 1 patient, intraoperative inspection showed no involvement of the arch. Three underwent ascending and subtotal arch replacemen…
Treating iliac aneurysm using the Nellix Endovascular Sac Sealing System.
2016
As endovascular treatment of abdominal aortic aneurysms has become established, there has been growing focus on treatment of the aneurysmal iliac artery. Isolated, large iliac aneurysms >30 mm pose a risk of rupture, but, in addition, 20% to 30% of abdominal aortic aneurysms are associated with iliac aneurysmal dilatation, which can compromise long-term outcomes. Endovascular solutions are evolving and until recently have utilized standard stent graft technology. The endovascular aortic sealing system was introduced as a new, effective method for the treatment of infrarenal aortic aneurysms. In this article, we present our recent extended use of the Nellix system, with or without a combinat…
Mid-Term Results of Endovascular Aneurysm Sealing in the Treatment of Abdominal Aortic Aneurysm With Unfavorable Morphology.
2020
Purpose: To report mid-term results of endovascular aneurysm sealing (EVAS) of abdominal aortic aneurysms (AAA) deemed unsuitable for a standard endovascular aneurysm repair (EVAR). Methods: A prospectively maintained database of 42 patients with EVAR-unfavorable anatomy treated by EVAS combined with chimney grafts in case of the proximal AAA neck shorter than 5 mm was analyzed. Early outcomes included final angiographic result, intra- and early post-operative deaths, and complications. Mid-term outcomes included all-cause mortality (ACM), aneurysm-related mortality (ARM), patency of the stents, occurrence of endoleaks, serious complications and graft failures defined as the AAA growth of m…
Use of covered chimney stents for pararenal aortic pathologies is safe and feasible with excellent patency and low incidence of endoleaks.
2012
Background To present the clinical experience of consecutive series with use of balloon-expandable and self-expanding chimney endografts (balloon-expandable covered stent group [BECS] vs self-expanding covered stent group [SECS]) in the endovascular treatment of challenging aortic pathologies requiring renal and/or visceral revascularization. Methods Between January 2009 and May 2011, data for 37 high-risk patients from one center and 35 patients from another institution, with pararenal aortic pathologies treated by the chimney endovascular technique, were prospectively collected. The chimney-graft technique is based on the deployment of a covered or bare-metal stent parallel to the aortic …