Search results for "Stents"

showing 10 items of 229 documents

Large platelets but not putative endothelial progenitor cells are associated with low strut coverage after drug-eluting stent implantation

2015

Objectives This study assessed whether different subsets of circulating endothelial and putative endothelial progenitor cells (CEC and EPC) correlate with stent strut coverage (SSC) using second generation optical coherence tomography (OCT). Background Due to the lack of imaging modalities with a resolution down to the magnitude of a few cells, the influence of EPC on endothelialisation of drug-eluting stents has not been assessed in patients. Methods In 37 patients, SSC of everolimus-eluting stents was assessed by OCT 5-7months after stent implantation. Different subsets of EPC (CD34(+)KDR(+), CD34(+)KDR(+)CD45(dim), CD133(+), CD3(+)CD31(+)), CEC (CD31(+)CD45(-)CD146(+)), and CD31(+)CD45(-…

Blood PlateletsMaleCD31medicine.medical_specialtymedicine.medical_treatmentCD34UrologyFlow cytometryBlood Vessel Prosthesis ImplantationAntigens CDmedicineHumansPlateletEverolimusProgenitor cellAgedEndothelial Progenitor Cellsmedicine.diagnostic_testbusiness.industryStentDrug-Eluting StentsKinase insert domain receptorMiddle AgedFlow CytometryVascular Endothelial Growth Factor Receptor-2Drug-eluting stentImmunologycardiovascular systemFemaleCardiology and Cardiovascular MedicinebusinessImmunosuppressive AgentsTomography Optical CoherenceInternational Journal of Cardiology
researchProduct

Carotid artery stenting in patients with brain meningioma.

2014

The association between carotid artery stenosis and brain meningioma is rather rare. Indeed, data in literature about this association are scarce and potential risks of carotid artery stenting using different protection devices are not known. We describe the endovascular treatment of severe carotid stenosis in two patients with intracranial meningioma.Riassunto L’associazione tra stenosi carotidea e menigioma cerebrale è piuttosto rara. Di conseguenza I dati su questa associazione sono scarsi in letteratura, e non sono noti i rischi potenziali dello stenting carotideo con l’uso di diversi apparati di protezione. Descriviamo il trattamento endovascolare di una stenosi carotidea serrata in du…

Brain NeoplasmsHumansCarotid StenosisFemaleStentsMiddle Agedcarotid artery stenosis brain meningioma carotid artery stentingMeningiomaSettore MED/22 - Chirurgia VascolareAgedAnnali italiani di chirurgia
researchProduct

Role of genetic factors on the effect of additional loading doses and two maintenance doses used to overcome clopidogrel hyporesponsiveness.

2014

Background and objective: Additional loading doses and higher maintenance doses (MDs) have been used to overcome hyporesponsiveness of clopidogrel. We aimed to investigate whether genetic polymorphisms of two cytochromes (CYP2C19 and CYP2C9) and ABCB1 modify effect of such dose-adjustment strategy.Materials and methods: We enrolled 118 patients undergoing elective or acute percutaneous coronary intervention (PCI) with drug eluting stent (DES). Platelet reactivity index (PRI) was measured using the vasodilator-stimulated phosphoprotein (VASP) index and a cut-off value of ≥60% was defined as hyporesponsiveness. Polymorphism of two cytochromes (CYP2C19, CYP2C9) and gene ABCB1 were determined. …

CYP2C9MaleMedicine (General)ATP Binding Cassette Transporter Subfamily BTiclopidinemedicine.medical_treatmentCYP2C19PharmacologyR5-920Percutaneous Coronary InterventionmedicinePotencyHumansProspective StudiesCYP2C19AlleleCYP2C9AllelesAgedCytochrome P-450 CYP2C9Medicine(all)Polymorphism GeneticDose-Response Relationship Drugbusiness.industryClopidogrel resistanceMicrofilament ProteinsPercutaneous coronary interventionABCB1Drug-Eluting StentsVASPMiddle AgedClopidogrelPhosphoproteinsClopidogrelCytochrome P-450 CYP2C19Drug-eluting stentPharmacogeneticsAutomotive EngineeringConventional PCIFemalebusinessCell Adhesion MoleculesPlatelet Aggregation InhibitorsClopidogrel resistance; VASP; CYP2C19; ABCB1; CYP2C9medicine.drugMedicina (Kaunas, Lithuania)
researchProduct

Prognostic role of endothelial dysfunction and carotid intima-media thickness in patients undergoing coronary stent implantation

2009

Aim. Impaired endothelial function and increased carotid intima-media thickness are key events in the atherosclerotic process and predict future cardiovascular events in subjects with and without coronary artery disease. The purpose of this study was to investigate whether the vasodilator response to increased flow in the brachial artery and the presence of carotid lesions may have a prognostic significance for in-stent restenosis in patients undergoing coronary angioplasty. Methods. The study population included 58 patients undergoing percutaneous coronary intervention (PCI) with stenting and at least 10 months of follow-up. All patients underwent ultrasound detection of brachial artery re…

Carotid Artery DiseasesMaleMiddle AgedPrognosisSettore MED/11 - Malattie Dell'Apparato CardiovascolareCoronary RestenosisProsthesis ImplantationCarotid ArteriesENDOTHELIAL DYSFUNCTIONHumansFemaleStentsEndothelium VascularProspective StudiesAngioplasty Balloon CoronaryTunica IntimaTunica Media
researchProduct

External stenting with a new polyester mesh reduces neointimal hyperplasia of vein grafts in a sheep model.

2007

Objective External stents placed around vein grafts have demonstrated effectiveness in reducing neointimal hyperplasia by preventing distension of the thin-walled vein grafts when exposed to arterial pressure. However, the ideal stent material has yet to be defined. The following study investigates the short- and long-term effects of an innovative polyester mesh stent designed with optimized adaptation of circumferential compliance. Methods Following in vitro definition of the ideal macro-porous polyester stent material, a total of 12 sheep underwent implantation of bilateral carotid artery vein graft bypasses. In six sheep, the short-term outcome (four weeks of implantation) was investigat…

Carotid Artery Diseasesmedicine.medical_specialtyCarotid Artery CommonCarotid arteriesmedicine.medical_treatmentPolyesters030232 urology & nephrologyBiomedical EngineeringMedicine (miscellaneous)BioengineeringVein graft030204 cardiovascular system & hematologyDistensionBiomaterials03 medical and health sciencesBlood Vessel Prosthesis Implantation0302 clinical medicineMedicineAnimalsSaphenous VeinNeointimal hyperplasiaPolyester meshHyperplasiaSheepbusiness.industryGraft Occlusion VascularStentGeneral MedicineSurgical Meshequipment and suppliesmedicine.diseaseSurgeryCompliance (physiology)Disease Models Animalsurgical procedures operativeSurgical meshStentsbusinessTunica IntimaDilatation PathologicThe International journal of artificial organs
researchProduct

Appropriateness criteria for the use of cardiac computed tomography, SIC-SIRM part 2: Acute chest pain evaluation; Stent and coronary artery bypass g…

2022

In the past 20 years, cardiac computed tomography (CCT) has become a pivotal technique for the noninvasive diagnostic workup of coronary and cardiac diseases. Continuous technical and methodological improvements, combined with fast growing scientific evidence, have progressively expanded the clinical role of CCT. Randomized clinical trials documented the value of CCT in increasing the cost-effectiveness of the management of patients with acute chest pain presenting in the emergency department, also during the pandemic. Beyond the evaluation of stents and surgical graft patency, the anatomical and functional coronary imaging have the potential to guide treatment decision-making and planning …

Chest PainHeart DiseasesInterventionalCardiologyGeneral Medicineheart diseaseRadiology Interventionalvalve diseaseX-Ray Computedcoronary computed tomography scancoronary artery bypass graftNeoplasmsHumansStentsstentCoronary Artery BypassCardiology and Cardiovascular MedicineTomography X-Ray ComputedCardiomyopathiesRadiologychest pain; coronary artery bypass graft; coronary computed tomography scan; heart disease; stent; valve disease; Chest Pain; Coronary Artery Bypass; Humans; Radiology Interventional; Stents; Tomography X-Ray Computed; Cardiology; Cardiomyopathies; Heart Diseases; NeoplasmsTomographyvalve disease.
researchProduct

Critical single proximal left arterial descending coronary artery stenosis to mimic chronic myocardial ischemia: a new model induced by minimal invas…

2008

<i>Background/Aims:</i> The present report examines a new pig model for progressive induction of high-grade stenosis, for the study of chronic myocardial ischemia and the dynamics of collateral vessel growth. <i>Methods:</i> Thirty-nine Landrace pigs were instrumented with a novel experimental stent (GVD stent) in the left anterior descending coronary artery. Eight animals underwent transthoracic echocardiography at rest and under low-dose dobutamine. Seven animals were examined by nuclear PET and SPECT analysis. Epi-, mid- and endocardial fibrosis and the numbers of arterial vessels were examined by histology. <i>Results:</i> Functional analysis showed a…

Chronic myocardial ischemiaMalemedicine.medical_specialtyTime FactorsPhysiologySwinemedicine.medical_treatmentCritical IllnessIschemiaMyocardial IschemiaCollateral CirculationCoronary stenosisCoronary AngiographySeverity of Illness IndexVentricular Dysfunction LeftInternal medicineCoronary CirculationmedicineAnimalsAngioplasty Balloon CoronaryTomography Emission-Computed Single-PhotonVascular diseasebusiness.industryCoronary StenosisStentPig modelStroke Volumemedicine.diseaseCoronary VesselsFibrosisStenosisDisease Models AnimalPositron-Emission TomographyCirculatory systemChronic DiseaseCardiologyFemaleStentsCardiology and Cardiovascular MedicinebusinessEchocardiography StressJournal of vascular research
researchProduct

The use of Endurant stent-graft for abdominal aortic aneurysm: the story about extension of instruction for use with persistent good results of stent…

2012

The Endurant stent-graft (Medtronic, Inc., Minneapolis, MN, USA) is a latest generation device for the treatment of abdominal aortic aneurysm. The idea behind designing such a graft came from the intention to broad the instruction for use (IFU) and to enable it to treat more challenging anatomy including the 10mm neck lengths, and more severe suprarenal and infrarenal angulations. Endurant stent-graft has active fixation through suprarenal stent with anchoring pins to provide migration resistance, optimized heights of stents and spacing between them for improved flexibility and conformability, low-profile delivery system with hydrophilic coating and controlled simple deployment mechanism. S…

Clinical Trials as TopicEvidence-Based Medicine10042 Clinic for Diagnostic and Interventional RadiologyEndovascular Procedures610 Medicine & healthProsthesis DesignRisk Assessment2705 Cardiology and Cardiovascular Medicine10020 Clinic for Cardiac Surgery2746 SurgeryBlood Vessel ProsthesisBlood Vessel Prosthesis ImplantationTreatment OutcomeRisk FactorsHumansStentsClinical CompetenceRegistriesLearning Curvestents endovascular procedures aortic aneurysm abdominalAortic Aneurysm Abdominal
researchProduct

Coronary artery dissection. Follow-up by MDCT.

2009

and a feature consistent with a thrombus, probably located in the false lumen (Figure, D). Based on these findings, a new coronary angiography with possible surgical revascularization was planned, but 12 hours after the MDCT examination, the patient experienced an episode of chest pain with ST-segment elevation from V1 to V5, complicated by electromechanical dissociation, and culminating in death. A post-mortem study was not performed. This case illustrates the usefulness of MDCT for follow-up of coronary stents located in proximal segments, and for identifying specific complications: extension of a dissection and even visualization of a coronary thrombus.

Coronary angiographyAged 80 and overMalemedicine.medical_specialtybusiness.industryFalse lumenGeneral MedicineDissection (medical)Coronary Artery Diseasemedicine.diseaseChest painCoronary thrombuscardiovascular systemmedicineHumansStentscardiovascular diseasesRadiologyThrombusmedicine.symptombusinessArtery dissectionTomography X-Ray ComputedSurgical revascularizationRevista espanola de cardiologia
researchProduct

Response by Meneveau and Ecarnot to Letter Regarding Article, “Optical Coherence Tomography to Optimize Results of Percutaneous Coronary Intervention…

2017

We read with interest the letters by Vallurupalli and Uretsky and also Dr Nadir relating to the results of the DOCTORS study (Does Optical Coherence Tomography Optimize Results of Stenting).1 We thank the authors for their insightful remarks. Vallurupalli and Uretsky raise an interesting point when they underline that a prolonged inflation time is superior to a rapid inflation/deflation technique in terms of both stent expansion and apposition. We acknowledge that we did not take stent inflation time into account in the case report form of the DOCTORS study. The arguments put forward by Vallurupalli and Uretsky suggest that this variable should be systematically recorded and reported. Howev…

Coronary angiographymedicine.medical_specialtyAcute coronary syndromemedicine.medical_treatment030204 cardiovascular system & hematologyCoronary Angiography03 medical and health sciencesPercutaneous Coronary Intervention0302 clinical medicineOptical coherence tomographyPhysiology (medical)medicineHumansMedical physicsIn patient030212 general & internal medicineAcute Coronary SyndromeCase report formmedicine.diagnostic_testbusiness.industryST elevationPercutaneous coronary interventionStentmedicine.diseaseCoronary VesselsSurgeryTreatment OutcomeStentsCardiology and Cardiovascular MedicinebusinessTomography Optical CoherenceCirculation
researchProduct