Search results for "Stiffne"

showing 10 items of 533 documents

Photoplethysmography Analysis of Artery Properties in Patients with Cardiovascular Diseases

2008

In this study arterial parameters of healthy subjects were compared to those of patients with cardiovascular diseases. The photoplethysmography (PPG) measurements of blood volume pulsations have been performed. Using a novel algorithm for analysis of simultaneously measured ear and finger PPG signals, arterial parameters were evaluated in representative groups of healthy subjects and patients with cardiovascular diseases. Digital volume pulse (DVP), pulse cycle duration (T), augmentation index (AIx), reflection index (RI) and transit time of reflected wave (RTT) were evaluated in every heartbeat cycle. Correlations between the AIx and RI, T and RTT, AIx and standard deviation of AIx, RTT an…

congenital hereditary and neonatal diseases and abnormalitiesmedicine.medical_specialtyHeartbeatPulse (signal processing)business.industryTransit timeBlood volumemedicine.diseasemedicine.anatomical_structureInternal medicinePhotoplethysmogrammedicineArterial stiffnessCardiologyIn patientbusinessArtery
researchProduct

Bio-based rigid high-density polyurethane foams as a structural thermal break material

2020

Abstract Sustainable development of building industry implies increasing usage of green materials. With this aim and for the intended application as a structural thermal break material, rigid high-density polyurethane foams have been manufactured using polyols derived from renewable resources - tall oil fatty acids. Thermal conductivity, compressive strength and stiffness of the foams of density ranging from ca. 100 to 680 kg/m3 have been determined. Comparison of the bio-based foams with reference foams derived from petrochemical resources demonstrated similar performance characteristics thus suggesting that bio-based foams can also serve as structural thermal break materials. Analytical m…

chemistry.chemical_classificationMaterials science0211 other engineering and technologiesStiffness020101 civil engineering02 engineering and technologyBuilding and ConstructionPolymer0201 civil engineeringchemistry.chemical_compoundThermal conductivityPetrochemicalCompressive strengthchemistry021105 building & constructionThermalmedicineGeneral Materials Sciencemedicine.symptomComposite materialCivil and Structural EngineeringPolyurethaneThermal breakConstruction and Building Materials
researchProduct

Guidelines to Select Between Self-Contained Electro-Hydraulic and Electro-Mechanical Cylinder

2020

This research paper presents guidelines on how to select between self-contained electro-hydraulic and electromechanical cylinders. An example based on the motion control of a single-boom crane is studied. The sizing process of the different off-the-shelf components is analyzed in terms of design impact when replacing a traditional valve-controlled hydraulic cylinder. The self-contained electro-hydraulic solution is the best choice when a risk for high impact forces is present, when the required output power level lies continuously above 2 kW, or when installation space, weight, and cost are critical design objectives. However, the electro-mechanical solution is expected to show more control…

0209 industrial biotechnologyComputer scienceStiffnessComputingMilieux_LEGALASPECTSOFCOMPUTING02 engineering and technologyLinear actuatorMotion controlSizingCylinder (engine)law.inventionControllabilityHydraulic cylinder020901 industrial engineering & automation020401 chemical engineeringlawControl theoryLinear motionVDP::Teknologi: 500::Maskinfag: 570medicine0204 chemical engineeringmedicine.symptomHydraulic machineryActuator
researchProduct

Domains of Physical Activity in Relation to Stiffness Index in the General Population.

2021

Background Regular exercise training represents an important modifier of arterial stiffness (AS). Therefore, sex‐specific relations between domains of physical activity (PA; commuting, domestic, and leisure‐time PA, including active sport and occupational PA) with AS were investigated. Methods and Results Stiffness index by digital photoplethysmography was investigated in 12 650 subjects from the GHS (Gutenberg Health Study). Self‐reported PA was evaluated by the “Short Questionnaire to Assess Health‐Enhancing Physical Activity” and reported as activity score peer week, being a combined measure of duration, frequency, and intensity of PA. Multivariable linear regression analysis demonstrat…

AdultMalemedicine.medical_specialtyEpidemiologyPopulationPhysical activityStiffness indexphysical activityPopulation basedRisk Assessmentpopulation basedPhysical medicine and rehabilitationSex FactorsVascular StiffnessRegular exerciseRisk FactorsGermanystiffness indexmedicineHumansHealthy LifestyleProspective StudiesPreventive CardiologyeducationExerciseOriginal Researcheducation.field_of_studybusiness.industryMiddle AgedProtective Factorsmedicine.diseaseLifestylemortalityPrimary PreventionCross-Sectional StudiesCardiovascular DiseasesArterial stiffnessPhysical EnduranceFemaleCardiology and Cardiovascular MedicinebusinessRisk Reduction Behaviorarterial complianceJournal of the American Heart Association
researchProduct

Predicting stiffness and strength of birch pulp:Polylactic acid composites

2016

This paper studies failure of birch pulp–polylactic acid composites. Stiffness and strength are calculated using the theory of short fibre composites and the results are compared to experimental data. The results differed from the experimental values by 0–6%. With less aligned fibres the short fibre theory is not feasible. The performance of the 40 wt% birch pulp – polylactic acid composite is predicted with X-ray microtomography based finite element modelling, and the results are compared with experiments. Stiffness results differed from experiments by 1–17% . By adding into the models a third material phase representing the interface between the fibres and the matrix, the stress–strain c…

microtomographyMaterials scienceComposite number02 engineering and technologyengineering.materialshort fibre composites strengthchemistry.chemical_compoundfibres0203 mechanical engineeringPolylactic acidimage analysisMaterials Chemistrymedicinepolymer matrix compositesComposite materialta216finite element modellingProperTunekuidutta214modelta114Mechanical EngineeringPulp (paper)Wood-plastic compositeStiffness021001 nanoscience & nanotechnologyMicrostructureFinite element method020303 mechanical engineering & transportschemistryshort fibre compositesMechanics of Materialskuva-analyysiCeramics and Compositesengineeringmedicine.symptomelastic properties0210 nano-technologystrengthelastiv properties
researchProduct

Experimental Characterization of the Properties of Double-Lap Needled and Hybrid Joints of Carbon/Epoxy Composites

2015

The effect of through-thickness reinforcement by thin 1 mm steel needles (z-pins) on the static tensile strength of double-lap joints of a carbon/epoxy composite was investigated. Two types of joints—z-pinned and hybrid (including glued ones)—were considered. The joints were reinforced in the overlap region with 9, 25, or 36 z-pins. Comparing mechanical properties of the double-lap joints with the corresponding characteristics of their unpinned counterparts, the z-pins were found to be highly effective: the strength and stiffness of the pinned joints increased up to 300% and 280%, respectively. These improvements were due to a transition in the failure mechanism from debonding of the joint …

Materials scienceComposite numberchemistry.chemical_elementmechanical propertieslcsh:TechnologyArticlez-pinsUltimate tensile strengthmedicineGeneral Materials ScienceComposite materiallcsh:MicroscopyReinforcementJoint (geology)lcsh:QC120-168.85lcsh:QH201-278.5hybridlcsh:TStiffnessEpoxycarbon/epoxy compositeShear (sheet metal)carbon/epoxy composite; mechanical properties; joints; z-pins; hybridchemistrylcsh:TA1-2040jointsvisual_artvisual_art.visual_art_mediumlcsh:Descriptive and experimental mechanicslcsh:Electrical engineering. Electronics. Nuclear engineeringmedicine.symptomlcsh:Engineering (General). Civil engineering (General)lcsh:TK1-9971CarbonMaterials
researchProduct

Reply

2017

NASH FIBROSIS STIFFNESS0301 basic medicineSettore MED/12 - Gastroenterologia03 medical and health sciences030104 developmental biology0302 clinical medicineHepatologybusiness.industryMedicine030211 gastroenterology & hepatologybusinessHepatology
researchProduct

Preventing the oil film instability in rotor-dynamics

2016

Horizontal rotor systems on lubricated journal bearings may incur instability risks depending on the load and the angular speed. The instability is associated with the asymmetry of the stiffness matrix of the bearings around the equilibrium position, in like manner as the internal hysteretic instability somehow, where some beneficial effect is indeed obtainable by an anisotropic configuration of the support stiffness. Hence, the idea of the present analysis is to check if similar advantages are also obtainable towards the oil film instability. The instability thresholds are calculated by usual methods, such as the Routh criterion or the direct search for the system eigenvalues. The results …

0209 industrial biotechnologyHistoryEngineeringMechanical equilibriummedia_common.quotation_subjectAngular velocity02 engineering and technologyRotordynamicsInstabilityEducationlaw.inventionOil film instability rotordynamics020901 industrial engineering & automation0203 mechanical engineeringlawmedicineEccentricity (behavior)media_commonStiffness matrixbusiness.industryRotor (electric)StiffnessMechanicsComputer Science Applications020303 mechanical engineering & transportsClassical mechanicsmedicine.symptombusinessJournal of Physics: Conference Series
researchProduct

Serial combination of non-invasive tools improves the diagnostic accuracy of severe liver fibrosis in patients with NAFLD

2017

SummaryBackground The accuracy of available non-invasive tools for staging severe fibrosis in patients with nonalcoholic fatty liver disease (NAFLD) is still limited. Aim To assess the diagnostic performance of paired or serial combination of non-invasive tools in NAFLD patients. Methods We analysed data from 741 patients with a histological diagnosis of NAFLD. The GGT/PLT, APRI, AST/ALT, BARD, FIB-4, and NAFLD Fibrosis Score (NFS) scores were calculated according to published algorithms. Liver stiffness measurement (LSM) was performed by FibroScan. Results LSM, NFS and FIB-4 were the best non-invasive tools for staging F3-F4 fibrosis (AUC 0.863, 0.774, and 0.792, respectively), with LSM ha…

AdultLiver CirrhosisMalemedicine.medical_specialtyLiver fibrosisDiagnostic accuracySensitivity and SpecificityGastroenterology03 medical and health sciences0302 clinical medicineNon-alcoholic Fatty Liver DiseaseLiver stiffnessFibrosisInternal medicineHistological diagnosisNonalcoholic fatty liver diseasemedicineHumansPharmacology (medical)In patientAgedHepatologybusiness.industryNon invasiveGastroenterologyMiddle Agedmedicine.disease030220 oncology & carcinogenesisFemale030211 gastroenterology & hepatologybusinessAlgorithmsAlimentary Pharmacology & Therapeutics
researchProduct

New Polylactic Acid Composites Reinforced with Artichoke Fibers

2015

In this work, artichoke fibers were used for the first time to prepare poly(lactic acid) (PLA)-based biocomposites. In particular, two PLA/artichoke composites with the same fiber loading (10% w/w) were prepared by the film-stacking method: the first one (UNID) reinforced with unidirectional long artichoke fibers, the second one (RANDOM) reinforced by randomly-oriented long artichoke fibers. Both composites were mechanically characterized in tensile mode by quasi-static and dynamic mechanical tests. The morphology of the fracture surfaces was analyzed through scanning electron microscopy (SEM). Moreover, a theoretical model, i.e., Hill's method, was used to fit the experimental Young's modu…

biocompositeScanning electron microscopy (SEM)Materials scienceMorphology (linguistics)Scanning electron microscopequasi-static tensile testsDynamic mechanical analysis (DMA)Moduluslcsh:TechnologyArticlefilm stackingFilm stackingQuasi-static tensile testschemistry.chemical_compoundMaterials Science(all)Polylactic acidArtichoke fiberPLA; artichoke fiber; biocomposites; film stacking; quasi-static tensile tests; dynamic mechanical analysis (DMA); scanning electron microscopy (SEM)Ultimate tensile strengthmedicinescanning electron microscopy (SEM).General Materials ScienceFiberComposite materiallcsh:Microscopylcsh:QC120-168.85biocompositesBiocompositesartichoke fiberlcsh:QH201-278.5lcsh:TPLA; artichoke fiber; biocomposites; film stacking; quasi-static tensile tests; dynamic mechanical analysis (DMA); scanning electron microscopy (SEM).Stiffnessdynamic mechanical analysis (DMA)Settore ING-IND/22 - Scienza E Tecnologia Dei Materiali/dk/atira/pure/subjectarea/asjc/2500chemistrylcsh:TA1-2040PLAlcsh:Descriptive and experimental mechanicslcsh:Electrical engineering. Electronics. Nuclear engineeringmedicine.symptomscanning electron microscopy (SEM)lcsh:Engineering (General). Civil engineering (General)lcsh:TK1-9971quasi-static tensile testMaterials
researchProduct