Search results for "Stéréovision"

showing 4 items of 4 documents

Polarization stereoscopic imaging prototype

2011

The polarization of light was introduced last ten years ago in the field of imaging system is a physical phenomenon that can be controlled for the purposes of the vision system. As that found in the human eyes, in general the imaging sensors are not under construction which is sensitive to the polarization of light. These properties can be measured by adding optical components on a conventional camera. The purpose of this thesis is to develop an imaging system that is sensitive both to the stereoscopic and to the state of polarization. As well as the visual system on a various of insects in nature such as bees, that are have capability to move in space by extracted relevant information from…

Mise en correspondancePolarization Imaging[INFO.INFO-OH]Computer Science [cs]/Other [cs.OH]Reconstruction 3DStereo Vision[ PHYS.COND.CM-GEN ] Physics [physics]/Condensed Matter [cond-mat]/Other [cond-mat.other]Imagerie polarimétrique[INFO.INFO-OH] Computer Science [cs]/Other [cs.OH]Stereo Matching[PHYS.COND.CM-GEN] Physics [physics]/Condensed Matter [cond-mat]/Other [cond-mat.other][PHYS.COND.CM-GEN]Physics [physics]/Condensed Matter [cond-mat]/Other [cond-mat.other][ INFO.INFO-OH ] Computer Science [cs]/Other [cs.OH]Feature extractionStéréovision
researchProduct

The compliance modelling of the pathology aorta of the type of aneurism

2015

The Abdominal Aorta Aneurysm (AAA) is a pathology that is defined by a localized and permanent dilation of the artery and which involves over 8.8% of the seniors. Currently, when a patient has a dilatation of the aorta leading to a surgery because of the rupture risk, the therapeutic decision is made depending on the diameter of the aneurysm. To determine this diameter, it is usually conducted an examination by medical imaging (ultrasound, CT, MRI...). However, it notes that the diagnosis can’t be satisfied with a single dimensional measurement face to induced risks: first of all, when the diameter exceed a certain growth, the risk of rupture can reach 50% but more than 5% of surgical proce…

PIVAnévrisme de l’aorte abdominaleModélisation avec interaction fluide/solideInter-comparaisonAbdominal aorta aneurysm[SPI.MECA] Engineering Sciences [physics]/Mechanics [physics.med-ph]StéréovisionIRM
researchProduct

Comparaison de la mesure des déformations de fantômes de l’aorte à partir d’image obtenues par IRM et stéréovision

2015

International audience; The study of the wall strain distribution could be helpful to improve the decision criterion for surgery of aortic aneurysm. Recently, numerical simulations can complete the data obtained from imaging measurement in order to develop reliable models. However, the used medical imaging tools are not experimentally validated, in metrological point of view. The aim of this study focused on accuracy and reliability of measurement obtained from kinetic MR sequences. The measures of deformations from MRI were compare to those obtained from stereovision system. Cylindrical phantom of silicone material similar to arterial behavior simulated a symmetric aneurysm was designed. A…

Physics[ SPI.MECA.GEME ] Engineering Sciences [physics]/Mechanics [physics.med-ph]/Mechanical engineering [physics.class-ph]Digital image correlationCardiac cycle0206 medical engineering3D reconstructionCylindrical phantom02 engineering and technology030204 cardiovascular system & hematology020601 biomedical engineeringImaging phantomMetrology[SPI.MECA.GEME]Engineering Sciences [physics]/Mechanics [physics.med-ph]/Mechanical engineering [physics.class-ph]03 medical and health sciences0302 clinical medicineMedical imaginganévrisme aorte abdominaleIRM cardiaquemesure par stéréovision des déformationsEcg signal[SPI.MECA.GEME] Engineering Sciences [physics]/Mechanics [physics.med-ph]/Mechanical engineering [physics.class-ph]métrologieSimulationBiomedical engineering
researchProduct

Étude du comportement de l'aorte dans le cadre de pathologie de type anévrisme

2013

International audience; Lorsqu'un patient présente une dilatation de l'aorte impliquant la possibilité d'une intervention chirurgicale (en raison du risque de rupture), la décision thérapeutique est prise en fonction du rapport des diamètres de l'artère. Toutefois cette mesure dimensionnelle est insuffisante et doit être compléter d'une estimation de la compliance de l'artère. C'est un travail complexe prenant en compte divers aspects. C'est une première approche qui présentée dans ce papier. Elle a pour objectif de quantifier les déformations de fantômes (répliques) en silicone ayant des géométries simplifiées mais proches de celle des patients présentant une pathologie de type anévrisme. …

[ SPI.MECA.GEME ] Engineering Sciences [physics]/Mechanics [physics.med-ph]/Mechanical engineering [physics.class-ph][ INFO.INFO-IM ] Computer Science [cs]/Medical Imaging[INFO.INFO-IM] Computer Science [cs]/Medical Imaging[PHYS.MECA.BIOM] Physics [physics]/Mechanics [physics]/Biomechanics [physics.med-ph][SPI.MECA.BIOM]Engineering Sciences [physics]/Mechanics [physics.med-ph]/Biomechanics [physics.med-ph]mesure de champs de déformation 3D[PHYS.MECA]Physics [physics]/Mechanics [physics][SPI.MECA.GEME]Engineering Sciences [physics]/Mechanics [physics.med-ph]/Mechanical engineering [physics.class-ph]anévrisme[SPI.MECA.BIOM] Engineering Sciences [physics]/Mechanics [physics.med-ph]/Biomechanics [physics.med-ph]compliance aorte[INFO.INFO-IM]Computer Science [cs]/Medical Imaging[ SPI.MECA.BIOM ] Engineering Sciences [physics]/Mechanics [physics.med-ph]/Biomechanics [physics.med-ph][PHYS.MECA] Physics [physics]/Mechanics [physics][PHYS.MECA.BIOM]Physics [physics]/Mechanics [physics]/Biomechanics [physics.med-ph][SPI.MECA.GEME] Engineering Sciences [physics]/Mechanics [physics.med-ph]/Mechanical engineering [physics.class-ph]Stéréovision[ PHYS.MECA.BIOM ] Physics [physics]/Mechanics [physics]/Biomechanics [physics.med-ph]IRMcompliance système vasculaire
researchProduct