Fall of Potential Measurement of the Earth Resistance in Urban Environments: Accuracy Evaluation
2019
Both Standards EN 50522 and IEEE 81 propose the fall of potential method (FPM) to carry out the measurement of the resistance to earth ( $R_{\text{ES}}$ ) of an earthing system (ES). However, in urban areas, the recommended distances between the ES and auxiliary electrodes are not easy to respect, due to the presence of buildings and tarmac. Furthermore, unknown buried metallic parts and interconnections among ESs could modify the earth potential profile of the area, affecting the measurement results. In this paper, the key-issues that influence the measured $R_{\text{ES}}$ when the FPM is used in an urban environment are presented. A parametric analysis, carried out with Comsol Multiphysic…
Electrical distribution substation remote diagnosis and control system
2014
This paper presents the conception, design, set up and realization of a prototype system for telemanagement of a MV/LV substation. The prototype has been developed according to the current standards. This system allows to monitor the status of the MV/LV substation box, of the medium voltage equipment, of the transformer and of the low voltage equipment. In particular, the system acts when some specified events occur. The prototype has been realized by using a DAQ; the software that implement the telemanagement system has been developed in LabVIEW environment. The system allows a remote monitoring of the quantities of interest that is carried out using the TeamViewer software able to establi…
Safety Concerns on Ground Fault Application Transfer Phenomenon in HV Installations
2007
When a fault to ground occurs in HV/MV substations supplied by a combined overhead-cable line, most of the fault current can be transferred and injected into the soil several kilometers far away from the fault location. This phenomenon is called "fault application transfer" and mostly concerns transition stations, where cables are connected to the overhead line. If the transition station is a dead-end steel pole structure, usually accessible to the general public, the local ground electrode could be inadequate to maintain ground potential rise within safety limits. Hence, dangerous touch and step voltages may appear at exposed locations. In the paper results of various computer simulations …
Characterization of the Magnetic Induction Field produced by Secondary Substations
2014
The aim of this paper is to develop a methodology for measuring the magnetic field distribution around the prefabricated secondary substations in vibrated reinforced concrete, as well as the definition of a methodology to determining the maximum value of magnetic induction produced by the substations in correspondence to nominal current of the transformer. As proposed has been developed in conformity with laws and standards and can be applied to active and passive secondary substations. The experimental validation of the proposed methodology, carried out by a measurements campaign whose results are reported, confirms the validity and returns a versatile and simple tool for the verification …
Critical issues and future prospects of the secondary substation in smart grid context
2014
This paper is focused on the new role of the secondary substation in the smart grids context. This innovative view has been proposed and developed in the framework of two Research Projects: NewCabELARC Project and Reipersei Project. The latter provides a concrete and comprehensive low cost solutions for the smart grid monitoring and control, allowing the real diffusion and integration of Distributed Generation and the full exploitation of Renewable Energy Sources. In this field, this paper shows how the secondary substation (SS) takes the role of smart transducer node where innovative devices can be located, collecting the measurement data coming from the field devices (power and energy met…
A study of the behaviour of earth electrodes connected together in resonant earthed neutral systems
2005
Inside urban areas the earth electrodes of the MV/lv substations are often electrically connected together so as to form a single extended earthing system. The advantages of the realization of an extended earthing system are the reduction of the current that each substation earth electrode injects in the soil during the fault and a better uniformity of the voltages to earth inside the urban area. In previous works, models for the study of extended earthing systems have been proposed. These models were valid for the case of single-line-to earth fault in isolated neutral MV networks. In this paper, the extended earthing system is analyzed in the case of a resonant earthed neutral MV network. …
Forensic Analysis of Fire in a Substation of a Commercial Center
2020
In this article, the authors discuss the legal liabilities of the professional engineer as both the engineer of record of a project and the construction site manager. In particular, this article analyzes the case of a fire at the end-user medium voltage–low-voltage (MV–LV) substation of a shopping center in Italy, which occurred a few years after the maintenance works on the electrical installation. The professional engineer who had designed and overseen the construction of the substation was accused of professional negligence. The authors through the examination of applicable technical standards, as well as of safety regulations, demonstrate that the professional engineer had acted diligen…