Search results for "Surgery."
showing 10 items of 15774 documents
Rates of Upper Facet Joint Violation in Minimally Invasive Percutaneous and Open Instrumentation: A Comparative Cohort Study of Different Insertion T…
2017
Background Minimally invasive pedicle screw placement may have a higher incidence of violation of the superior cephalad unfused facet joint. Study Aims We investigated the incidence and risk factors of upper facet joint violation in percutaneous robot-assisted instrumentation versus percutaneous fluoroscopy-guided and open transpedicular instrumentation. Methods A retrospective study including all consecutive patients who underwent lumbar instrumentation, fusion, and decompression for spondylolisthetic stenosis and degenerative disk disease was conducted between January 2012 and January 2016. All operations were performed by the same surgeon; the patients were divided into three groups acc…
Walking and Running Require Greater Effort from the Ankle than the Knee Extensor Muscles.
2016
The knee and ankle extensors as human primary antigravity muscle groups are of utmost importance in a wide range of locomotor activities. Yet, we know surprisingly little about how these muscle groups work, and specifically, how close to their maximal capacities they function across different modes and intensity of locomotion. Therefore, to advance our understanding of locomotor constraints, we determined and compared relative operating efforts of the knee and ankle extensors during walking, running, and sprinting.Using an inverse dynamics biomechanical analysis, the muscle forces of the knee and ankle extensors during walking (1.6 m·s), running (4.1 m·s), and sprinting (9.3 m·s) were quant…
Micromechanical Properties and Collagen Composition of Ruptured Human Achilles Tendon
2012
Background:The Achilles tendon is one of the strongest tendons in the human body, and yet it frequently ruptures, which is a substantial clinical problem. However, the cause of ruptures remains elusive.Hypothesis:Ruptured human Achilles tendon displays inferior biomechanical properties and altered collagen composition compared with noninjured tendon.Study Design:Controlled laboratory study.Methods:Biopsy specimens were obtained at the rupture site and the noninjured part of the tendon (internal controls) in 17 patients with acute Achilles tendon rupture. Age- and weight-matched human cadaveric Achilles tendons (external controls) were also obtained. Tendon samples were tested micromechanica…
Transverse fracture-dislocation of the sacrum: a diagnostic pitfall and a surgical challenge.
2002
Transverse fracture-dislocations of the sacrum are rare. Associated lesions of the lumbosacral spine as well as neurological injuries are common. Conventional radiographs of the pelvis often fail to clearly visualize the fracture. Delayed diagnosis increases the risk of progressive neurological disfunction. True lateral sacral views and CT-scans with 3-dimensional reconstructions are very helpful in establishing the full extent of the injury. These examinations should be considered in all patients with a history of high energy trauma and clinical signs indicating lumbosacral injury, such as severe low back pain and neurological disturbances of the lower extremities. The management of transv…
Urethral Reconstruction in Anterolateral Thigh Flap Phalloplasty: A 93-Case Experience
2019
BACKGROUND: Urethral reconstruction in anterolateral thigh flap phalloplasty cannot always be accomplished with one flap, and the ideal technique has not been established yet. In this article, the authors' experience with urethral reconstruction in 93 anterolateral thigh flap phalloplasties is reported. METHODS: Ninety-three anterolateral thigh phalloplasties performed over 13 years at a single center were retrospectively reviewed to evaluate outcomes of the different urethral reconstruction techniques used: anterolateral thigh alone without urethral reconstruction (n = 7), tube-in-tube anterolateral thigh flap (n = 5), prelaminated anterolateral thigh flap with a skin graft (n = 8), antero…
Cementless total hip replacement with subtrochanteric femoral shortening for severe developmental dysplasia of the hip.
2003
Total joint replacement in patients suffering from developmental dysplasia of the hip poses specific technical difficulties due to insufficient bone stock at the site of the original and secondary acetabulum and a narrow, cranially displaced proximal femur. Twelve hips with severe congenital dislocation (4 Crowe type II, 5 type III, 3 type IV) were treated with cementless, porous structured total hip replacement. The cup was implanted at the anatomic height, a femoral segment was resected below the minor trochanter to reduce the femoral component in all cases. One femoral component was exchanged for a longer stem after 2 months due to insufficient fit and fill. After a mean follow-up of 5.1…
The Retrograde Tibial Nail: presentation and biomechanical evaluation of a new concept in the treatment of distal tibia fractures.
2013
Displaced distal tibia fractures require stable fixation while minimizing secondary damage to the soft tissues by the surgical approach and implants. Antegrade intramedullary nailing has become an alternative to plate osteosynthesis for the treatment of distal metaphyseal fractures over the past two decades. While retrograde intramedullary nailing is a standard procedure in other long bone fractures, only few attempts have been made on retrograde nailing of tibial fractures. The main reasons are difficulties of finding an ideal entry portal and the lack of an ideal implant for retrograde insertion. The Retrograde Tibial Nail (RTN) is a prototype intramedullary implant developed by our group…
A ten-year follow-up of the Reflection cementless acetabular component.
2008
We reviewed the long-term results at ten to 12 years of 118 total hip replacements in 109 patients using a second-generation hemispherical cementless acetabular component (Reflection) designed to address the problem of backside wear. Five patients (five hips) died and six patients (seven hips) were lost to follow-up. The remaining 98 patients (106 hips) had a mean age of 62.9 years (34.0 to 86.2) A rate of revision for aseptic loosening of 0.9%, and predictable results were found with respect to radiological evidence of fixation, lack of pain, walking ability, range of movement and function. One component was revised for aseptic loosening, and of the 101 hips (95.2%) that did not have a rev…
Clinical performance of a highly portable, scanning calcaneal ultrasonometer.
2001
The aim of this study was to establish a normative database, assess precision, and evaluate the ability to identify women with low bone mass and to discriminate women with fracture from those without for a highly portable, scanning calcaneal ultrasonometer: the QUS-2. Fourteen hundred and one Caucasian women were recruited for the study. Among them were 794 healthy women 25–84 years of age evenly distributed per 10-year period to establish a normative database. Of these, 171 aged 25–34 years were defined as the young normal group for the purpose of T-score determination. Precision was assessed within 1 day (short-term) and over a 16-week period (long-term) in 79 women aged 25–84 years. Five…
Muscle strength characteristics and central bone mineral density in women with recent onset rheumatoid arthritis compared with healthy controls.
1999
Muscle strength and bone mineral density (BMD) at the lumbar spine (BMDspine) and femoral neck (BMDfem) were determined in 20 healthy women and in 20 women with recent onset rheumatoid arthritis (RA). The mean duration of articular symptoms of the patients was eleven months and none of them had used glucocorticoids or disease modifying antirheumatic drugs. BMDs were measured by dual x-ray absorptiometry (DXA). Knee extension, trunk extension, and flexion as well as grip strength were measured with David 200 and Digitest dynamometers. BMDspine (1.17 g/cm2 and 1.20 g/cm2) and BMDfem (0.98 g/cm2 and 0.96 g/cm2) between the women with early RA and healthy women did not differ. However, knee ext…