Search results for "Surgery."

showing 10 items of 15774 documents

Treatment of distal intraarticular tibial fractures: A biomechanical evaluation of intramedullary nailing vs. angle-stable plate osteosynthesis

2015

In factures of the distal tibia with simple articular extension, the optimal surgical treatment remains debatable. In clinical practice, minimally invasive plate osteosynthesis and intramedullary nailing are both routinely performed. Comparative biomechanical studies of different types of osteosynthesis of intraarticular distal tibial fractures are missing due to the lack of an established model. The goal of this study was first to establish a biomechanical model and second to investigate, which are the biomechanical advantages of angle-stable plate osteosynthesis and intramedullary nailing of distal intraarticular tibial fractures. Seven 4(th) generation biomechanical composite tibiae feat…

musculoskeletal diseasesmedicine.medical_specialtyIntra-Articular Fracturesmedicine.medical_treatmentBone ScrewsTorsion MechanicalBone Nailsmedicine.disease_causeOsteotomyWeight-bearingBiomechanical Phenomenalaw.inventionWeight-BearingIntramedullary rodFixation (surgical)lawBone platemedicineHumansGeneral Environmental ScienceOrthodonticsOsteosynthesisbusiness.industrymusculoskeletal systemBiomechanical PhenomenaFracture Fixation IntramedullaryOsteotomySurgeryTibial FracturesFeasibility StudiesGeneral Earth and Planetary SciencesImplantbusinessBone PlatesInjury
researchProduct

The influence of the decompressive operation on the intracranial pressure and the pressure-volume relation in patients with severe head injuries.

1978

Measurements of intracranial pressure by ventricular catheter were performed in 47 patients with severe head injuries. Thirty-three patients with decompressive operations such as osteoclastic craniotomy and dilatation by means of duraplastic have been compared with 14 patients with closed heads with regard to volume pressure response (intracranial elasticity). This was determined either by intraventricular injection of 2 ml saline or by drainage of cerebrospinal fluid. The examination clearly shows that patients with closed heads have a much higher intracranial elasticity than patients who have decompressive operations, so that in the first group minor differences of the intracranial volume…

musculoskeletal diseasesmedicine.medical_specialtyIntracranial Pressuremedicine.medical_treatmentCerebrospinal fluidHyperventilationmedicineCraniocerebral TraumaHumansSalineCraniotomyIntracranial pressureNeuroradiologyRetrospective Studiesmedicine.diagnostic_testbusiness.industryInterventional radiologyElasticitySurgeryAnesthesiaBrain InjuriesSurgeryNeurology (clinical)Neurosurgerymedicine.symptombusinessActa neurochirurgica
researchProduct

Two different posterior-stabilized mobile-bearing TKA designs: navigator evaluation of intraoperative kinematic differences

2020

Purpose: The purpose of this study was to compare two types of posterior-stabilized (PS) mobile-bearing (MB) total knee arthroplasties (TKAs). The hypothesis was that no major differences were going to be found among the two TKA designs. Methods: Two cohorts of patients who were divided according to implant design (Cohort A, new design gradually reducing radius PS MB TKA; Cohort B, traditional dual-radius PS MB TKA) were analyzed by means of intraoperative navigation. All operations were guided by a non-image-based navigation system that recorded relative femoral and tibial positions in native and implanted knees during the following kinematic tests: passive range of motion (PROM), varus–va…

musculoskeletal diseasesmedicine.medical_specialtyKinematicsKnee Jointmedicine.medical_treatmentComparisonKinematicsPromProsthesis DesignProsthesis03 medical and health sciences0302 clinical medicinemedicineHumansOrthopedics and Sports MedicinePosterior-stabilized kneeRange of Motion ArticularSettore ING-IND/15 - Disegno E Metodi Dell'Ingegneria IndustrialeArthroplasty Replacement KneeOrthodontics030222 orthopedicsKnee laxitybusiness.industryTKAPosterior stabilized030229 sport sciencesKinematicmusculoskeletal systemNavigationBiomechanical PhenomenaSurgeryCohortOrthopedic surgerySurgeryMobile bearingKnee ProsthesisRange of motionbusinessMUSCULOSKELETAL SURGERY
researchProduct

Kinematics and kinetics analysis of midfoot joints of 30 normal subjects during walking

2016

Abstract Introduction There is not enough evidence in form of clinical studies regarding the behavior of the midfoot joints in dynamic situations such us walking or running. The present work aims to study the mechanical behavior of midfoot joints with a multisegmented foot model with special interest in joint moments and their clinical significance. Subjects and methods A computerized 3-dimensional gait study was performed on healthy male adult subjects with a neutral Foot Posture Index (FPI) (from 0 to +5) during walking. Joint angle and external moments were estimated with a multisegment foot model that considers three separate segments (forefoot, rearfoot and hallux) and graphs and value…

musculoskeletal diseasesmedicine.medical_specialtyKinematicsMovimiento del mediopiéMidfoot joints movementKinematicsWalking03 medical and health sciencesCinética0302 clinical medicineStance phaseFase de apoyomedicineCinemáticaJoint (geology)OrthodonticsMomentos del mediopiéArticulaciones del mediopiéStance phasebusiness.industryForefootWork (physics)Midfoot joints moments030229 sport sciencesGeneral MedicineSagittal planeMarchabody regionsMidfoot jointsTransverse planeKineticsmedicine.anatomical_structurePhysical therapybusinesshuman activities030217 neurology & neurosurgeryFoot (unit)Revista Española de Podología
researchProduct

Patient Specific Instrumentation for Total Knee Arthroplasty: a Literature Review

2014

During the past decade, total knee arthroplasty (TKA) has been markedly increased. Recently, patient-specific custom cutting guides have been commercially introduced in order to achieve an accurate component alignment during TKA. In fact, these cutting blocks are specific to a patient’s knee anatomy and should help the surgeons to perform bone cuts, reducing the complexity of conventional alignment and sizing tools. Nevertheless, there are critical arguments against patient-specific cutting guides for routine use, such as poor evidence and higher costs. Additionally, there are still no mild and long-term results available that describe the clinical outcomes following patient-specific instru…

musculoskeletal diseasesmedicine.medical_specialtyKnee JointTotal knee arthroplastytotal knee arthroplasty patient specific instrumentation PSI knee ProsthesisSettore MED/33 - Malattie Apparato LocomotoreMedicineHumansOrthopedics and Sports MedicineComponent alignmentInstrumentation (computer programming)Arthroplasty Replacement KneeEvidence-Based Medicinebusiness.industryMagnetic Resonance ImagingSurgeryTreatment OutcomePatient specific instrumentationSurgery Computer-AssistedOrthopedic surgeryPractice Guidelines as TopicPhysical therapySurgerybusinessKnee ProsthesisTomography X-Ray Computed
researchProduct

Kinematics of the patellofemoral joint. Investigations on a computer model with reference to patellar fractures.

1990

Patellofemoral kinematics were studied on a computer model. The articulating point of the patella moves from distal to proximal during flexion, until the quadriceps tendon starts to turn around the femur tendo-femoral gliding. The pattern of patellofemoral movement consists of a gliding and rolling component, the latter at its maximum at the beginning of flexion. The pathway of the instant centers of motion moves from dorsal to ventral during flexion. Stress analysis shows that the contact area is at all times the area of maximum bending stress. The distal part of the patella is the part with mechanical stress at all angles of flexion. The conclusions to be drawn for treatment are that frac…

musculoskeletal diseasesmedicine.medical_specialtyKnee Jointmedicine.medical_treatmentMovementKinematicsModels BiologicalFractures BonemedicineInternal fixationHumansOrthopedics and Sports MedicineFemurComputer Simulationbusiness.industryBiomechanicsGeneral MedicineAnatomyPatellamusculoskeletal systemBiomechanical Phenomenamedicine.anatomical_structureOrthopedic surgerySurgeryPatellaQuadriceps tendonContact areabusinessArchives of orthopaedic and trauma surgery
researchProduct

Effect of saddle height on skin temperature measured in different days of cycling

2016

Infrared thermography can be useful to explore the effects of exercise on neuromuscular function. During cycling, it could be used to investigate the effects of saddle height on thermoregulation. The aim of this study was to examine whether different cycling postures, elicited by different knee flexion angles, could influence skin temperature. Furthermore, we also determined whether the reproducibility of thermal measurements in response to cycling differed in the body regions affected or not affected by saddle height. Sixteen cyclists participated in three tests of 45 min of cycling at their individual 50 % peak power output. Each test was performed in a different knee flexion position on …

musculoskeletal diseasesmedicine.medical_specialtyMaterials scienceThermal imagingMedicina esportiva03 medical and health sciences0302 clinical medicinemedicineExerciseSaddleReproducibilityMultidisciplinaryResearchBike-fit030229 sport sciencesRepeatabilityThermoregulationmusculoskeletal systemReliabilityTrunkReproducibilitySurgeryThermographyInfrared thermographyBody regionFisiologia humanaCycling030217 neurology & neurosurgeryBiomedical engineeringSpringerPlus
researchProduct

Herniation of an intervertebral disc with cauda compression syndrome in childhood.

1979

A case of a lumbosacral disc herniation of traumatic origin with compression of the cauda equina in a child is reported. The problems of early diagnosis, timely operative procedure, and prognosis of neurological deficit of operated disc herniation in childhood are discussed.

musculoskeletal diseasesmedicine.medical_specialtyNeurologyDisc herniationLumbar VertebraeCauda Equinabusiness.industryCauda equinaIntervertebral discCompression (physics)Surgerymedicine.anatomical_structureNeurologymedicineHumansParalysisFemaleNeurology (clinical)businessChildSpinal Cord CompressionLumbosacral jointIntervertebral Disc DisplacementNeuroradiologyNeurological deficitJournal of neurology
researchProduct

Molekulare Signalwege der aseptischen Endoprothesenlockerung (Molecular pathways in aseptic loosening of orthopaedic endoprosthesis)

2008

Operative joint replacement to treat disabling joint conditions secondary to degenerative and inflammatory arthritides has become one of the most efficacious and cost-effective procedures to relieve pain and restore joint function. However, prosthetic implants are not built to last forever and osteolysis and aseptic loosening has been associated with prosthetic arthroplasties since their introduction. The functional life of a synthetic joint is influenced by many factors including the material of the implant, operation procedures and the surgeon involved, as well as patient-related factors. Although promising developments have been achieved in this field, more than 10% of all implants still…

musculoskeletal diseasesmedicine.medical_specialtyOsteolysisSignal Pathwaysbusiness.industryJoint replacementmedicine.medical_treatment10051 Rheumatology Clinic and Institute of Physical MedicineBiomedical EngineeringAseptic loosening2204 Biomedical EngineeringImplant failure610 Medicine & healthmedicine.diseaseSurgeryProsthetic implantsMedicineSmall particlesImplantbusiness
researchProduct

Primäre Ellenbogenprothese bei distalen Humerustrümmerfrakturen

2004

The use of hip- and shoulder arthroplasty in elderly patients for grossly displaced intraarticular fractures is being more and more accepted. Total elbow replacement (TER) has not been considered as an option for the treatment of extensively comminuted fractures of the distal humerus because surgeons feel the outcome is not predictable after TER generally. On the basis of a Medline literature research of this issue and the documented results based on the improvement of the designs of the implants, operative technique and the selection of patients, TER has a definite role in the treatment of some fractures of the distal humerus. We retrospectively reviewed forty-nine acute distal humeral fra…

musculoskeletal diseasesmedicine.medical_specialtyOsteosynthesisbusiness.industrymedicine.medical_treatmentElbowDistal humerusArthroplastyProsthesisSurgerymedicine.anatomical_structuremedicineSurgeryHumerusIn patientComplicationbusinessAktuelle Traumatologie
researchProduct