Search results for "Suture Technique"
showing 10 items of 61 documents
Simplified orthotopic ileocaecal pouch (Mainz pouch) for bladder substitution
2005
Suture needles in Oral Surgery: Alterations depending on the type and number of sutures
2011
This study examined whether the number and type of sutures used in oral surgery influence two ad hoc variables (incision plane and displaced area), which are two variables related to whether the suture needle is suitable for the task. Seventy-five TB-15 needles were studied, which were used to suture between zero and three mucosa and/subperiosteal sutures, producing 15 groups with 5 needles in each one. The incision plane and displaced area were measured for each group, which are two variables related to how the needle has worn and altered. Statistical treatment was conducted using the Kruskal-Wallis H test to compare multiple values and the Mann-Whitney U test to compare pairs. A multi-sta…
VITOM® 3D system in surgeon microsurgical vascular training: our model and experience.
2017
LETTER TO EDITOR
Measuring Intraoperative Oesophageal Anastomotic Tension With a Knot-Pusher–Mounted Dynamometer Is Not Quite Ready for Take-Off
2021
A Continuous Suture Anastomosis Outperforms a Simple Interrupted Suture Anastomosis in Esophageal Elongation.
2020
Abstract Introduction Long-gap esophageal atresia represents a distinct entity among the esophageal atresia spectrum. In many patients, achieving a reasonable anastomosis depends on some millimeters of tissue. We aimed to determine what effect the suturing technique would have on esophageal ex vivo elongation as it may determine the strength of a primary anastomosis. Materials and Methods In an analysis of porcine esophagi from animals for slaughter (100–120 days old with a weight of 100–120 kg), we determined esophageal length gain of simple continuous and simple interrupted suture anastomoses subjected to linear traction until linear breaking strength was reached. Statistical power of 80%…
Three single loops enhance the biomechanical behavior of the transtibial pull-out technique for posterior meniscal root repair
2017
Purpose: To investigate the effect of applying an additional suture to enhance the biomechanical behavior of the suture–meniscus construct used during the transtibial pull- out repair technique. Methods: A total of 20 fresh-frozen porcine tibiae with intact medial menisci were used. In one half of all speci- mens (N = 10), two non-absorbable sutures were passed directly over the meniscal root from the tibia side of the meniscus to the femoral side (2SS). In other ten specimens, three sutures were passed over the meniscal root (3SS). All specimens were subjected to cyclic loading followed by load-to-failure testing. Displacement of the construct was recorded at 100, 500, and 1000 cycles. Fur…
Lens implant selection with absence of capsular support.
2001
If contact lens or spectacle correction is not viable, little debate exists that the secondary placement of an intra-ocular lens (IOL) is the method of choice in the absence of capsular support. The choice of IOL mainly depends on the preoperative status of the eye (eg, aphakia in children) and the selected location for the implant. Theoretically, there are several IOL implantation approaches in cases without capsular support: an angle-supported anterior chamber (AC) IOL, an iris-fixated ACIOL, an iris-sutured or iris-fixated posterior chamber (PC) IOL and a transsclerally sutured PCIOL. No consensus exists, however, on the indications as well as on the relative safety and efficacy of these…
The "sandwich technique" for iris-fixated phakic intraocular lens implantation.
2006
ABSTRACT PURPOSE: To describe a new technique of implantation of the Artisan/Verisyse phakic intraocular lens (PIOL). METHODS: After PIOL insertion into the anterior chamber, a bolus of a high viscosity ophthalmic viseosurgical device (OVD) is placed over the optic, separating it widely from the endothelium. RESULTS: The technique decreases the chance of endothelial damage during enclavation. CONCLUSIONS: A bolus of a high viscosity OVD placed on the anterior surface of the Artisan/Verisyse PIOL may make enclavation safer. [J Refract Surg. 2006;22:96-98.]
The extent of adhesion induction through electrocoagulation and suturing in an experimental rat study.
2008
Objective To investigate the effect of three types of peritoneal trauma occurring during surgery (high-frequency bipolar current, suturing, and mechanical damage) on postoperative adhesion formation in a rodent animal model. Design Randomized, controlled experimental trial in an in vitro animal model. Setting Laboratory facilities of a university department of obstetrics and gynecology. Animal(s) Thirty-five female Wistar rats. Intervention(s) Bilateral experimental lesions were created on the abdominal wall in every animal. The effect of minimal electrocoagulation was examined by creating lesions (n = 14) through sweeps of a bipolar forceps with a duration of 1 second and standardized pres…
Surgical repair of acute Achilles tendon rupture with an end-to-end tendon suture and tendon flap.
2015
Abstract Background Achilles tendon ruptures are becoming more common. Complications after open or minimally invasive surgery are: recurrent rupture (2–8%), wound breakdown, deep infections, granuloma, and fistulas. The authors expose their experience with a personal technique. Materials In 8 patients with acute rupture of Achilles tendon the surgery was performed at least 25 days after trauma. Clinical exam and MR demonstrated in all case a total lesion of tendon. After a posterolateral skin incision the tendon stumps were debrided and suture in end-to-end fashion. A tendon flap was harvested from the proximal part of the tendon, in order to protect and reinforce the suture itself. A plast…