Search results for "Suture"
showing 10 items of 145 documents
Long-term Results After Transconjunctival Resuturing of the Scleral Flap in Hypotony Following Trabeculectomy
2013
Purpose To present the 4-year follow-up results in the surgical treatment of hypotony following trabeculectomy with mitomycin C in glaucoma patients with additional flap sutures. Design Retrospective interventional case series. Methods Since 2006, 53 patients with hypotony maculopathy attributable to overfiltration following glaucoma surgery (trabeculectomy with mitomycin C) were included in this institutional study. We were able to follow up intraocular pressure (IOP) and distance-corrected visual acuity in 33 (62%) over 4 years, whereas all were followed over 2 years. To elevate IOP, we placed tangential transconjunctival sutures through the scleral flap and connected them to the adjacent…
The Penile Plication Procedure: An Alternative Method for Straightening Penile Deviation
1991
AbstractThe number of reported cases of congenital and acquired penile deviation is evidently increasing. We describe our experience with the penile plication procedure, which we used to treat 40 patients with penile deviation. Postoperatively, all patients regained the ability for sexual intercourse, with potency remaining unimpaired. Of the patients 96% were completely satisfied with the result of the operation. Sustained complications have not been observed. To avoid major trauma the surgical intervention should not include removal of ellipsoids from the penile tunica albuginea as proposed by Nesbit. Since the penile plication method produces equally good results in terms of performance …
Importance of absorbable surgical sutures for the prevention of stitch abscess after surgery in patients with oral squamous cell carcinoma
2017
Background To elucidate the significance of absorbable surgical sutures in the occurrence of stitch abscess after surgery in patients with oral squamous cell carcinoma (SCC). Material and Methods The subjects were 251 patients who underwent excision and/or reconstruction and/or neck dissection for oral SCC using absorbable surgical sutures. Detection rates and characteristics of patients with stitch abscess were retrospectively evaluated by comparing between our present and previous data. Results There was only one stitch abscess among the 251 patients. A significant difference in the incidence of stitch abscess was found between the present data and our previous data. Of course, no signifi…
Sutureless ciliary sulcus supported intraocular lens with transiridal anchoring haptics.
2003
We report a technique for implanting intraocular lenses (IOLs) in the ciliary sulcus in eyes without capsule support. The IOL design allows it to be implanted without fixation sutures. The lens was implanted in 3 aphakic eyes without capsule support.
Scheimpflug biometry of the anterior segment after implantation of foldable iris-fixated lenses.
2006
ABSTRACT PURPOSE: To evaluate intraocular dimensions of the anterior segment of myopic phakic eyes after implantation of foldable iris-fixated lenses. METHODS: Seventeen myopic eyes that received a foldable iris-fixated phakic intraocular lens (PIOL) were assessed. Distances between the cornea and the IOLoptic edge and between the IOL optic and the crystalline lens were evaluated using Scheimpf lug photography 3 months postoperatively. RESULTS: The average postoperative distance between the central corneal endothelium and the anterior surface of the IOL was 2.01±0.26 mm. The distance between the corneal endothelium and the peripheral edge of the IOL averaged 1.32±0.18 mm at the 12 o'clock p…
Tentacle-shaped mesh for fixation-free repair of umbilical hernias
2019
Purpose: Mesh fixation and broad overlap represent an open issue in umbilical hernia repair. A proprietary-designed implant with tentacle straps at its boundary has been developed to ensure a suture-free repair and a broader coverage of the abdominal wall. The study describes the results of umbilical hernia procedures carried out with the tentacle-shaped implant and the related surgical technique. Methods: A proprietary tentacle-shaped flat mesh having a central body with integrated radiating arms at its edge was used to repair large umbilical hernias in 62 patients. The implant was placed in preperitoneal sublay. The friction of the straps, crossing the abdominal wall thanks to a special n…
Endothelial cell loss after toric iris-fixated phakic intraocular lens implantation: three-year follow-up.
2007
ABSTRACT PURPOSE: To study quantitative changes in endothelial cell count after implantation of the toric iris-fixated phakic intraocular lens. METHODS: A prospective, non-randomized, self-controlled clinical trial was conducted of 40 eyes (28 myopic, 12 hyperopic) of 23 patients with high ametropia and astigmatism. Non-contact computer-assisted endothelial microscopy was performed before and I1 2, and 3 years after surgery. RESULTS: In the myopic group, mean preoperative endothelial cell count was 3179±531 cells/mm p 2 (range: 1800 to 3900 cells/mm2). The mean intraindividual endothelial cell loss was -1.83±2.25% (range: -9.09% to 0%) in the first year; -1.83+2.95% (range: -7.74% to 3.80%)…
Simplified Orthotopic Ileocecal Pouch (Mainz Pouch) for Bladder Substitution
2003
Objective To report operative modifications that render construction of the orthotopic Mainz pouch more simple, namely formation of the pouch using absorbable staples and utilization of the ileocecal valve as an antireflux mechanism. Patients and methods Between January 2001 and May 2002 out of 92 cystectomy cases, 21 patients (20 males and 1 female) underwent a simplified orthotopic Mainz pouch. The ureters were implanted via Wallace or Nesbit technique in the supravalvular portion of the ileocecal valve. The mean (range) age was 58 (43 - 74) years and the mean follow-up is 11.6 months (range 1 - 27). Results No staple-related complications were encountered. Four renal units (8.8 %) were d…
Change in pupil size after implantation of an iris-fixated toric phakic intraocular lens
2005
Purpose To evaluate the changes in pupil size after implantation of an iris-supported toric phakic intraocular lens (TPIOL) for correction of myopia and hyperopia with astigmatism. Setting Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods Twenty-two myopic eyes and 9 hyperopic eyes were included in the study. The mean age of the 2 groups was 34 years and 40 years, respectively. The scotopic pupil size was measured with a handheld infrared pupillometer (Colvard, Oasis Medical) before and 6 months after implantation of the TPIOL. All examinations were performed under scotopic conditions after 2 minutes of dark adaptation with the fellow eye covered. Intraindi…
Occurrence of silk stitch abscess after surgery in patients with oral squamous cell carcinoma
2012
Objectives: To elucidate the predisposing factors and clinical characteristics related to the occurrence of stitch abscess after surgery in patients with oral squamous cell carcinoma (SCC). Patients and Methods: The subjects were 232 patients who underwent excision and/or reconstruction and/or neck dissection for oral SCC using silk sutures for high ligation of the blood vessels. Detection rates and characteristics of patients with stitch abscess were retrospectively evaluated by comparing patients with and without stitch abscesses after surgery diagnosed by ultrasonography and findings of various modalities in 232 patients. Several echogenic dots with subtle acoustic shadows in a hypoechoi…