Search results for "Sutures"
showing 10 items of 41 documents
Suture Materials: Do They Affect Fistula and Stricture Rates in Flap Urethroplasties?
2003
<i>Introduction:</i> The effect of suture materials on urethroplasty complications is debated. Indeed, materials with a delayed absorption might either reduce the incidence of fistulas by ensuring a prolonged approximation of neo-urethral edges or increase the risk of urethral strictures due to a prolonged tissue reaction during suture absorption. We retrospectively evaluated the role of suture materials in the complication rate of urethroplasty procedures performed in our institution over a 10-year period. <i>Patients and Methods:</i> Three hundred and thirty-six boys undergoing a flap procedure (parameatal based, preputial tube, or onlay preputial flap) for hypospa…
Healthcare associated infection: novel strategies and antimicrobial implants to prevent surgical site infection
2010
This report is based on a Hygienist Panel Meeting held at St Anne's Manor, Wokingham on 24–25 June 2009. The panel agreed that greater use should be made of antiseptics to reduce reliance on antibiotics with their associated risk of antibiotic resistance. When choosing an antiseptic for clinical use, the Biocompatibility Index, which considers both the microbiocidal activity and any cytotoxic effects of an antiseptic agent, was considered to be a useful tool. The need for longer and more proactive post-discharge surveillance of surgical patients was also agreed to be a priority, especially given the current growth of day-case surgery. The introduction of surgical safety checklists, such as…
Technical Detail on Nerve Coaptation in Phalloplasty: Use of Fibrin Glue Instead of Sutures.
2019
Antibacterial suture vs silk for the surgical removal of impacted lower third molars. A randomized clinical study.
2015
Background The aim of this study was to evaluate the clinical and microbiological impact of an antibacterial suture (Monocryl® Plus) in the surgical removal of I3M. Material and Methods A “split-mouth”, prospective pilot clinical study was designed involving 20 patients programmed for the surgical removal of I3M. Each side was randomly sutured with Monocryl® Plus or silk suture and removed for microbiological study 72 hours and 7 days after surgery. Presence of SSI, wound bleeding and the degree of discomfort associated with each type of suture material (scored by means of a visual analog scale) were evaluated. The level of contamination of each material was observed under the scanning elec…
The effect of surgical suture material on osteoclast generation and implant-loosening
2020
Background: Implant loosening - either infectious or aseptic- is a still a major complication in the field of orthopaedic surgery. In both cases, a pro-inflammatory peri-prosthetic environment is generated by the immune system - either triggered by bacteria or by implant wear particles - which leads to osteoclast differentiation and osteolysis. Since infectious cases in particular often require multiple revision surgeries, we wondered whether commonly used surgical suture material may also activate the immune system and thus contribute to loss of bone substance by generation of osteoclasts. Methods: Tissue samples from patients suffering from infectious implant loosening were collected intr…
Three single loops enhance the biomechanical behavior of the transtibial pull-out technique for posterior meniscal root repair
2017
Purpose: To investigate the effect of applying an additional suture to enhance the biomechanical behavior of the suture–meniscus construct used during the transtibial pull- out repair technique. Methods: A total of 20 fresh-frozen porcine tibiae with intact medial menisci were used. In one half of all speci- mens (N = 10), two non-absorbable sutures were passed directly over the meniscal root from the tibia side of the meniscus to the femoral side (2SS). In other ten specimens, three sutures were passed over the meniscal root (3SS). All specimens were subjected to cyclic loading followed by load-to-failure testing. Displacement of the construct was recorded at 100, 500, and 1000 cycles. Fur…
Occurrence of silk stitch abscess after surgery in patients with oral squamous cell carcinoma
2012
Objectives: To elucidate the predisposing factors and clinical characteristics related to the occurrence of stitch abscess after surgery in patients with oral squamous cell carcinoma (SCC). Patients and Methods: The subjects were 232 patients who underwent excision and/or reconstruction and/or neck dissection for oral SCC using silk sutures for high ligation of the blood vessels. Detection rates and characteristics of patients with stitch abscess were retrospectively evaluated by comparing patients with and without stitch abscesses after surgery diagnosed by ultrasonography and findings of various modalities in 232 patients. Several echogenic dots with subtle acoustic shadows in a hypoechoi…
Continuous Microfiber Wire Mandrel‐Less Biofabrication for Soft Tissue Engineering Applications
2022
Suture materials are the most common bioimplants in surgical and clinical practice, playing a crucial role in wound healing and tendon and ligament repair. Despite the assortment available on the market, sutures are still affected by significant disadvantages, including failure in mimicking the mechanical properties of the tissue, excessive fibrosis, and inflammation. This study introduces a mandrel-less electrodeposition apparatus to fabricate continuous microfiber wires of indefinite length. The mandrel-less biofabrication produces wires, potentially used as medical fibers, with different microfiber bundles, that imitate the hierarchical organization of native tissues, and tailored mechan…
Bone quality in the midpalate for temporary anchorage devices.
2009
Objective The aim of the present study was to quantitatively assess the bone quality of the palatal bone from an implantologic standpoint. Material and methods The material consisted of palatal tissue blocks of autopsy material from 22 subjects (19 male, three female), between 18 and 63 years of age. The specimens comprised the anterior part of median palate (APMP) from about 7 mm behind the incisive foramen (first premolar regions), the middle part of median palate (MPMP, second premolar region), and the posterior part of the median palate (PPMP, first molar region). They were prepared in the transversal plane using ground-thin-section technology. The midpalatal areas of the different part…
Morphology and preliminary biomechanical interpretation of mandibular sutures in Metoposaurus krasiejowensis (Temnospondyli, Stereospondyli) from the…
2019
Altres ajuts: CERCA Programme/Generalitat de Catalunya The morphology of the mandibular sutures in the Late Triassic temnospondyl Metoposaurus krasiejowensis has been examined in order to determine their role in mandible biomechanics. Until now, no histological studies of mandibular sutures in extinct vertebrates were performed, in contrast to cranial sutures. As a consequence, mandibular suture interpretations herein are based mainly on comparisons with previous studies of cranial sutures and with 3D cranial finite element analysis of this species. A total of 32 standard thin sections were studied under standard petrographic microscope observations in order to differentiate the morphology …