Search results for "Sutures"

showing 10 items of 41 documents

Biomechanical comparison between the modified rolling-hitch and the modified finger-trap suture techniques

2016

Purpose: The purpose of this study was to characterize the biomechanical effect of two grasping suture techniques used during ligament reconstruction: the modified rolling-hitch (MRH) and the modified finger-trap (MFT). Methods: Flexor profundus tendons were harvested from fresh pig hind-leg trotters. Each specimen was mounted on an electro-mechanic universal testing machine (Instron 3367). In half of all tendons (15 specimens), the suture was passed around the tendon following the MRH knot (Group 1). In the remaining half of all tendons (15 specimens), the suture was passed over a distance of 30 mm according to the MFT suture technique (Group 2). As per standard intra-operative technique, …

SwineTendons03 medical and health sciences0302 clinical medicineSuture (anatomy)Finger InjuriesSettore MED/33 - Malattie Apparato LocomotoremedicineAnimalsOrthopedics and Sports MedicineOrthodontics030222 orthopedicsUniversal testing machineSuturesbusiness.industrySuture TechniquesSignificant differenceStiffness030229 sport sciencesGeneral MedicinePlastic Surgery ProceduresTendonmedicine.anatomical_structureLigamentSurgerymedicine.symptomMFT modified finger-trap grasping suture tendon suture suture ligament reconstructionbusinessArchives of Orthopaedic and Trauma Surgery
researchProduct

Continuous Microfiber Wire Mandrel‐Less Biofabrication for Soft Tissue Engineering Applications

2022

Suture materials are the most common bioimplants in surgical and clinical practice, playing a crucial role in wound healing and tendon and ligament repair. Despite the assortment available on the market, sutures are still affected by significant disadvantages, including failure in mimicking the mechanical properties of the tissue, excessive fibrosis, and inflammation. This study introduces a mandrel-less electrodeposition apparatus to fabricate continuous microfiber wires of indefinite length. The mandrel-less biofabrication produces wires, potentially used as medical fibers, with different microfiber bundles, that imitate the hierarchical organization of native tissues, and tailored mechan…

TendonsBiomaterialsWound HealingSuturesTissue EngineeringTensile Strengthbiofabrication biomaterials host response medical textiles inflammation macrophagic response.Biomedical EngineeringAnimalsPharmaceutical ScienceRatsAdvanced Healthcare Materials
researchProduct

Renal transplantation by automatic anastomotic device in a porcine model

2015

Automatic vascular staplers for vascular anastomoses in kidney transplantation may dramatically reduce the operative time and, in particular, warm ischemia time, thus increasing the outcome of transplantation. Ten pigs underwent kidney auto-transplantation by automatic anastomotic device. Kidneys were collected by laparotomy with selective ligations at the renal hilum and perfused with cold storage solution. To overcome the shortage in length of renal hilum, a tract of the internal jugular vein was harvested to increase the length of the vessels. The anastomoses were totally performed by the use of the anastomotic device. On 10 kidney transplants, nine were successful and no complications o…

Vascular anastomosiAnastomosis deviceAnimalSwineMedicine (all)Anastomosis SurgicalBiomedical EngineeringMedicine (miscellaneous)Mechanical vascular sutureWarm ischemia timeBioengineeringKidneyIliac ArteryKidney TransplantationBiomaterialAnastomosis device; Kidney transplantation; Mechanical vascular sutures; Vascular anastomosis; Warm ischemia time; Anastomosis Surgical; Animals; Automation; Disease Models Animal; Female; Iliac Artery; Kidney; Kidney Transplantation; Renal Artery; Swine; Biomaterials; Biomedical Engineering; Bioengineering; Medicine (miscellaneous); Medicine (all)AutomationDisease Models AnimalSettore MED/18 - Chirurgia GeneraleRenal ArteryAnimalsFemale
researchProduct

Suture needles in Oral Surgery: Alterations depending on the type and number of sutures

2011

This study examined whether the number and type of sutures used in oral surgery influence two ad hoc variables (incision plane and displaced area), which are two variables related to whether the suture needle is suitable for the task. Seventy-five TB-15 needles were studied, which were used to suture between zero and three mucosa and/subperiosteal sutures, producing 15 groups with 5 needles in each one. The incision plane and displaced area were measured for each group, which are two variables related to how the needle has worn and altered. Statistical treatment was conducted using the Kruskal-Wallis H test to compare multiple values and the Mann-Whitney U test to compare pairs. A multi-sta…

medicine.medical_specialtyMaterial testingOral surgeryOral Surgical ProceduresMaterials testingOral surgerySuture (anatomy)Third molarMedicineProspective StudiesGeneral DentistryOrthodonticsSuturesbusiness.industrySuture needlesSuture TechniquesScanning electron microscope:CIENCIAS MÉDICAS [UNESCO]SurgeryOtorhinolaryngologyNeedlesUNESCO::CIENCIAS MÉDICASResearch-ArticleSurgeryOral Surgerybusiness
researchProduct

Innovative barriers for peritoneal adhesion prevention: liquid or solid? A rat uterine horn model.

2005

Objective To compare the effects of solid barriers (PDLA membrane and foil, Interceed), innovative barrier solutions (Adept and Hyalobarrier Gel, phospholipid emulsion), and Ringer’s lactate solution in preventing postsurgical peritoneal adhesions in the rat. Design Prospective, randomized experimental study. Setting Rat model in an academic research environment. Animal(s) Female, nonpregnant Wistar rats. Intervention(s) Standardized surgical injuries were applied to the parietal and visceral peritoneum and the uterine horns. The barrier agents were applied and the wound was closed. A second-look laparoscopy was performed 31 days after surgery to assess adhesion formation. Main Outcome Meas…

medicine.medical_specialtyRinger's LactatePolymersPolyestersAdhesion (medicine)Tissue AdhesionsPeritoneal DiseasesSeverity of Illness IndexIcodextrinmedicineAnimalsHyalobarrierCellulose OxidizedAdhesion preventionLactic AcidRats WistarLaparoscopymedicine.diagnostic_testSuturesbusiness.industryUterusObstetrics and GynecologyUterine hornsAdeptMembranes ArtificialProstheses and Implantsmedicine.diseaseSurgeryRatsReproductive MedicinePeritoneal adhesionEmulsionsFemaleIsotonic SolutionsPeritoneumbusinessGelsFertility and sterility
researchProduct

Technical Detail on Nerve Coaptation in Phalloplasty: Use of Fibrin Glue Instead of Sutures.

2019

medicine.medical_specialtySuturesComputer scienceUrologyEndocrinology Diabetes and MetabolismObstetrics and GynecologyFibrin Tissue AdhesiveSurgeryPsychiatry and Mental healthEndocrinologyReproductive MedicinemedicineSex Reassignment SurgeryTissue AdhesivesPhalloplastyGenitaliaFibrin glueSexual medicine reviews
researchProduct

Measuring Intraoperative Oesophageal Anastomotic Tension With a Knot-Pusher–Mounted Dynamometer Is Not Quite Ready for Take-Off

2021

medicine.medical_specialtySuturesDynamometerbusiness.industryTension (physics)Suture TechniquesmedicineSurgeryAnastomosisbusinessDigestive System Surgical ProceduresSurgeryKnot (mathematics)Surgical Innovation
researchProduct

A Direct Comparison of Seprafilm, Adept, Intercoat, and Spraygel for Adhesion Prophylaxis

2010

Background Commercially available agents for adhesion prophylaxis are legion but there is a lack of direct comparisons between them. Here we compare four of the most commonly used adhesion barriers against a control group in a clinically relevant rat model. Material and Methods Standardized lesions were created in Wistar rats using electrocautery and suturing. Subsequently, the experimental lesions were treated with Seprafilm (n = 30), Adept (n = 30), Intercoat (n = 30), Spraygel (n = 30), or no barrier (n = 30). The resulting adhesions were examined 14 d postoperatively. Results The mean area covered by adhesion was 77% in the control group, 46% in animals treated with Seprafilm, 54% in an…

medicine.medical_specialtySuturesbusiness.industryCauteryRat modelAdhesion (medicine)Tissue AdhesionsAdeptmedicine.diseaseIcodextrinRatsSurgeryGlucoseModels AnimalCell AdhesionmedicineAnimalsWounds and InjuriesSurgeryHyaluronic AcidRats WistarbusinessGelsGlucansJournal of Surgical Research
researchProduct

Three single loops enhance the biomechanical behavior of the transtibial pull-out technique for posterior meniscal root repair

2017

Purpose: To investigate the effect of applying an additional suture to enhance the biomechanical behavior of the suture–meniscus construct used during the transtibial pull- out repair technique. Methods: A total of 20 fresh-frozen porcine tibiae with intact medial menisci were used. In one half of all speci- mens (N = 10), two non-absorbable sutures were passed directly over the meniscal root from the tibia side of the meniscus to the femoral side (2SS). In other ten specimens, three sutures were passed over the meniscal root (3SS). All specimens were subjected to cyclic loading followed by load-to-failure testing. Displacement of the construct was recorded at 100, 500, and 1000 cycles. Fur…

medicine.medical_specialtyUltimate loadSwineMenisci Tibial03 medical and health sciences0302 clinical medicineSettore MED/33 - Malattie Apparato LocomotoremedicineAnimalsCyclic loadingOrthopedics and Sports Medicinemeniscal root repair meniscal root menisci injury menisciTibiaArthroplasty Replacement KneeFibrous jointOrthodontics030222 orthopedicsSuturesTibiabusiness.industrySuture TechniquesSignificant differenceStiffnessMeniscal suture030229 sport sciencesGeneral MedicineBiomechanical Phenomenamedicine.anatomical_structureOrthopedic surgerySurgerymedicine.symptombusinessArchives of Orthopaedic and Trauma Surgery
researchProduct

Ureteral injury during left colectomy for cancer: Laparoscopic management. A case report

2020

Abstract Introduction Iatrogenic ureteral lesions may occur after any abdominal and pelvic surgery. They are severe and can affect renal function and even vital prognosis. This study aimed to determine the clinical aspects and the therapeutic approaches of a lower third injury of the ureter during a laparoscopic left colectomy. Presentation of case An 81 year-old-man with left-sided colon cancer underwent laparoscopic left colectomy. During surgery there was a continuous full-thickness solution of the left ureter for which an end-to-end ureteral anastomosis was performed. In the postoperative period the patient underwent multiple urological and radiological interventional procedures due to …

medicine.medical_specialtymedicine.medical_treatmentIschemiaCase ReportAnastomosisurologic and male genital diseases03 medical and health sciences0302 clinical medicineUreterUreteral lesionmedicineLaparoscopyGynecological surgerymedicine.diagnostic_testbusiness.industryUretero-ureteral anastomosisStentmedicine.diseaseSurgeryIntracorporeal laparoscopic suturesmedicine.anatomical_structure030220 oncology & carcinogenesisLaparoscopic left colectomyIatrogenic ureteral lesion030211 gastroenterology & hepatologySurgeryPresentation (obstetrics)businessLigationInternational Journal of Surgery Case Reports
researchProduct