Search results for "Swine"

showing 10 items of 466 documents

Effects of BIS076 in a model of osteoarthritis induced by anterior cruciate ligament transection in ovariectomised rats

2015

Background Osteoarthritis (OA) is the most frequent articular disease and a leading cause of disability. There is a need for effective treatments able to slow the progression of disease. Some of the available treatments are dietary supplements providing natural components. Recent studies have shown that estrogen deficiency contributes to the pathophysiological events of OA progression. Methods We have used the anterior cruciate ligament transection model of OA in ovariectomised rats to study the effects of BIS076, a new formulation of a natural porcine cartilage extract associated with hydroxyapatite (as a source of calcium) and vitamin D3. Cartilage degradation, proteoglycan depletion and …

medicine.medical_specialtySwineOvariectomyType II collagenOsteoarthritisCartilage Oligomeric Matrix ProteinBIS076DinoprostoneBone remodelingRheumatologyOsteoprotegerinInternal medicineOsteoarthritismedicineAnimalsOrthopedics and Sports MedicineRats WistarVitamin DCollagen Type IIGlycosaminoglycansBone mineralCartilage oligomeric matrix proteinbiologybusiness.industryTissue ExtractsCartilageAnterior Cruciate Ligament InjuriesArticular cartilage damageOsteoarthritis Kneemedicine.diseasePeptide FragmentsSurgeryRatsDisease Models Animalmedicine.anatomical_structureEndocrinologyDurapatiteTreatment Outcomebiology.proteinAnterior cruciate ligament transection modelCytokinesFemaleMatrix Metalloproteinase 3businessOvariectomised ratsBiomarkersResearch ArticleBMC Musculoskeletal Disorders
researchProduct

Plain film, CT and MRI sensibility in the evaluation of intraorbital foreign bodies in an in vitro model of the orbit and in pig eyes.

2000

Detection and characterization of intraorbital foreign bodies (IFB) is fundamental in acute trauma setting, preventing inflammatory sequelae or complications related to IFB movements when a MRI study is planned. Papers concerning plain film and CT sensibility in IFB detection show controversial results. For this reason we investigated plain film, CT and MRI sensibility in the evaluation of IFB. For an in vitro model, specimens of dry and fresh wood, glass, iron, plastic and graphite were immersed in animal lard and in a 0.9 % sodium chloride plus 3.5 g/dl human serum albumin solution. Specimens of different size and nature where also implanted into enucleated pig eyes. Air bubbles were intr…

medicine.medical_specialtySwineRadiodensityRadiographyPlain filmEyeSensitivity and SpecificityIn vitro modelmedicineAnimalsHumansRadiology Nuclear Medicine and imagingmedicine.diagnostic_testbusiness.industryUltrasoundMagnetic resonance imagingGeneral MedicineMagnetic Resonance ImagingEye Injuries Penetratingmedicine.anatomical_structureEye Foreign BodiesTomographyRadiologybusinessTomography X-Ray ComputedOrbitOrbit (anatomy)European radiology
researchProduct

In vitro comparison of platinum-iridium and gold tip electrodes: lesion depth in 4 mm, 8 mm, and irrigated-tip radiofrequency ablation catheters

2009

Aims We compared a newly developed irrigated gold tip electrode ablation catheter and a gold tip 4 and 8 mm catheter with the corresponding platinum–iridium (Pt) tip catheters in an in vitro setting. Methods and results In a flow chamber simulating physiological flow conditions, radiofrequency catheter ablation was performed on tissue samples of porcine endomyocardium and liver. Lesion depth, energy and temperature delivery, and popping frequency were determined. Two hundred and fifty-three ablations were conducted. Four and eight millimetre, gold tip electrode catheters produced significantly deeper lesions compared with the Pt tip electrode (liver 4 mm: 4.67 ± 1.7 vs. 2.9 ± 1.0 mm, P < 0.…

medicine.medical_specialtySwineRadiofrequency ablationmedicine.medical_treatmentchemistry.chemical_elementIn Vitro TechniquesIridiumlaw.inventionlawPhysiology (medical)medicineAnimalsIridiumCardiac Surgical ProceduresElectrodesPlatinumbusiness.industryLesion depthAblationSurgeryCatheterLiverchemistryRadiofrequency catheter ablationModels AnimalElectrodeCatheter AblationGoldCardiology and Cardiovascular MedicinePlatinumbusinessNuclear medicineEuropace
researchProduct

Imaging of Ventriculoperitoneal Shunt Complications: Comparison of Whole Body Low-Dose Computed Tomography and Radiographic Shunt Series.

2016

OBJECTIVE To determine diagnostic value and radiation exposure of low-dose computed tomography (LD-CT) compared to radiographic shunt series (SS) for the detection of ventriculoperitoneal (VP) shunt complications. METHODS Fourteen VP shunts were implanted in 7 swine cadavers. Mechanical complications were induced in 50% of VP shunts. Low-dose CT (80 kVp, 10 mAs, Pitch = 1.5) and SS were acquired. Dose area product (DAP) and effective doses for SS and LD-CT were collected. Scoring of diagnostic confidence and blinded readings of SS and CT data were performed. RESULTS The sensitivity of LD-CT was high (0.97; 95% confidence interval, 0.91-1.00) with excellent interobserver agreement (κ = 0.88)…

medicine.medical_specialtySwineRadiographyComputed tomographyRadiation DosageEffective dose (radiation)Sensitivity and SpecificityVentriculoperitoneal Shunt030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicinePostoperative ComplicationsRadiation ProtectionmedicineAnimalsRadiology Nuclear Medicine and imagingMedical physicsSingle-Blind MethodWhole Body Imagingmedicine.diagnostic_testbusiness.industryLow doseReproducibility of ResultsRadiation ExposureConfidence intervalRadiographic Image EnhancementDose area productRadiographic Image Interpretation Computer-AssistedTomographybusinessNuclear medicineTomography X-Ray Computed030217 neurology & neurosurgeryShunt (electrical)Journal of computer assisted tomography
researchProduct

Button batteries and typical swallowed foreign bodies can be differentiated in high-resolution X-Rays.

2021

Abstract Background Button battery ingestions have emerged as an increasing medical issue in recent years, especially for children. The frequent use of these energy sources in small appliances and toys is responsible for their ubiquitous occurrence in households. In addition to other possible foreign bodies, button batteries are particularly dangerous as they can cause severe complications in the aerodigestive tract. Objective The study aimed for a detailed analysis of specific radiographic identifiers of button batteries and similarly configured potential esophageal foreign bodies in high-resolution X-ray scans. Methods A selection of potentially hazardous button batteries - in cases of in…

medicine.medical_specialtySwineRadiographyHigh resolutionPoison control03 medical and health sciences0302 clinical medicineElectric Power SuppliesEsophagus030225 pediatricsmedicineAnimalsHumans030223 otorhinolaryngologyChildForeign BodiesButton batterybusiness.industryX-RaysReproducibility of ResultsGeneral Medicinemedicine.diseaseForeign BodiesFrequent useOtorhinolaryngologyPediatrics Perinatology and Child HealthRadiologyForeign bodybusinessEnergy sourceInternational journal of pediatric otorhinolaryngology
researchProduct

Modulation of central corneal thickness by various riboflavin eyedrop compositions in porcine corneas

2012

Purpose To evaluate the modulatory effect of various riboflavin 0.1% and 0.2% compositions on the central corneal thickness (CCT) in fresh porcine corneas. Setting Department of Ophthalmology, Johannes Gutenberg University of Mainz, Mainz, Germany. Design Experimental study. Methods The CCT in freshly enucleated porcine globes was measured by ultrasound pachymetry before and after (if applicable) deepithelialization and every 10 minutes thereafter during 120 minutes of eyedrop application. In Groups 1 and 2 (controls), no eyedrops were applied. In Groups 3 and 4, isotonic riboflavin eyedrops were used. In Groups 5 to 9, hypotonic riboflavin eyedrops were given. In Groups 10 and 11, preparat…

medicine.medical_specialtySwineRiboflavinRiboflavinCorneaCorneal edemaCorneaOphthalmologyIsotonicAnimalsMedicineBody Weights and MeasuresUltrasonographyPhotosensitizing Agentsbusiness.industryCorneal EdemaOsmolar ConcentrationUltrasound pachymetryHydrogen-Ion ConcentrationSensory SystemsSurgeryOphthalmologyCross-Linking ReagentsOphthalmic solutionsmedicine.anatomical_structurePhotochemotherapySurgeryOphthalmic SolutionsbusinessJournal of Cataract and Refractive Surgery
researchProduct

OneShot-M: A New Device for Close Laparoscopy Pneumoperitoneum

2018

Introduction. The induction of pneumoperitoneum is the first and most critical phase of laparoscopy, due to the significant risk of serious vascular and visceral complications. The closed technique for the creation of pneumoperitoneum could lead to several surgical complications. The present study aimed to overcome the complications associated with the insertion of Veress needle, improving its use, and facilitating the rapid creation of pneumoperitoneum. Methods. Thirty large white female pigs were enrolled in our study. A common plunger was modified in order to allow the passage of a 15-cm long Veress needle. This method was applied to 26 laparoscopic procedures (26 pigs) of several speci…

medicine.medical_specialtySwineSettore VET/09 - Clinica Chirurgica Veterinaria030230 surgeryCritical phase03 medical and health sciencesabdominal entry0302 clinical medicinePneumoperitoneumAnimalsMedicineNew deviceSignificant riskIntraoperative ComplicationsNeedlestick InjuriesLaparoscopyminimally invasive surgeryVeress needlemedicine.diagnostic_testbusiness.industryInsufflationoperating room technologymedicine.diseaseVeress needleinnovationSurgerybody regionsSettore MED/18 - Chirurgia GeneraleNeedles030220 oncology & carcinogenesisModels AnimalFemaleLaparoscopySurgerybusinessPneumoperitoneum ArtificialSurgical Innovation
researchProduct

Accuracy of automatic airway morphometry in computed tomography-correlation of radiological-pathological findings.

2010

Abstract Objectives Airway morphology shows characteristic changes in different pathologies. This study assesses the accuracy of a current automatic airway assessment technique by correlating CT images of porcine airways to histological slices of the same localization. Materials and methods Four isolated and ventilated porcine lungs were frozen in a liquid nitrogen bath and examined with a CT scanner (MDCT). This technique both preserved normal radiomorphological appearance and made it possible to slice the specimens for histological examination for subsequent correlation. The parameters wall thickness (WT), wall percentage (WP), and total diameter (TD) were assessed by computer-aided measu…

medicine.medical_specialtySwineStatistics as TopicBronchiIn Vitro TechniquesSensitivity and SpecificityImaging phantomPattern Recognition AutomatedCorrelationBronchoscopyMedicineAnimalsRadiology Nuclear Medicine and imagingPathologicalbusiness.industryReproducibility of ResultsHistologyGeneral MedicineTracheaRadiological weaponCalipersRadiographic Image Interpretation Computer-AssistedRadiologyTomographybusinessAirwayNuclear medicineTomography X-Ray ComputedAlgorithmsEuropean journal of radiology
researchProduct

Intracoronary Infusion of Thioflavin-S to Study Microvascular Obstruction in a Model of Myocardial Infarction

2015

Abstract Introduction and objectives Microvascular obstruction exerts deleterious effects after myocardial infarction. To elucidate the role of ischemia-reperfusion injury on the occurrence and dynamics of microvascular obstruction, we performed a preliminary methodological study to accurately define this process in an in vivo model. Methods Myocardial infarction was induced in swine by means of 90-min of occlusion of the mid left anterior descending coronary artery using angioplasty balloons . Intracoronary infusion of thioflavin-S was applied and compared with traditional intra-aortic or intraventricular instillation. The left anterior descending coronary artery perfused area and microvas…

medicine.medical_specialtySwineUltraviolet RaysSus scrofaMyocardial InfarctionLumen (anatomy)Myocardial Reperfusion InjuryAnterior Descending Coronary ArteryCoronary AngiographyBalloonMicrocirculationCoronary CirculationInternal medicineOcclusionPhotographymedicineAnimalsInfusions Intra-ArterialBenzothiazolesMyocardial infarctionFluorescent Dyesbusiness.industryMicrocirculationGeneral Medicinemedicine.diseaseCoronary VesselsDisease Models AnimalThiazolesCoronary OcclusionCoronary occlusionMicrovesselsCardiologybusinessPerfusionRevista Española de Cardiología (English Edition)
researchProduct

Metabolic adaptation and neuroprotection differ in the retina and choroid in a piglet model of acute postnatal hypoxia.

2013

Hypoxic-ischemic insults to the neonatal brain may cause neurodevelopmental disorders. Vulnerability of different areas of the neural tissue to hypoxic-ischemic stress might be explained by either heterogeneous sensitivity to oxygen or neuroprotective capability. Our understanding of regional heterogeneity is still incomplete in terms of metabolic reconfiguration and/or activation of neuroprotective mechanisms.We studied, by western blotting, reverse-transcriptase PCR, and tandem mass spectrometry, the response of retina and choroid at protein, gene, and metabolic levels during hypoxia in a piglet model of acute postnatal hypoxia.We evidenced a metabolic shift towards glycolysis in choroid …

medicine.medical_specialtySwineanimal diseasesBlotting WesternMetabolic adaptationNeuroprotectionRetinafluids and secretionsStress PhysiologicalTandem Mass SpectrometryInternal medicinemedicineAnimalsHypoxiaRetinaintegumentary systembusiness.industryChoroidReverse Transcriptase Polymerase Chain ReactionHypoxia (medical)Hypoxia-Inducible Factor 1 alpha Subuniteye diseasesBlotmedicine.anatomical_structureEndocrinologyAnimals NewbornAnesthesiaPediatrics Perinatology and Child Healthsense organsChoroidmedicine.symptombusinessEnergy MetabolismGlycolysisSignal TransductionPediatric research
researchProduct