Search results for "Switche"
showing 10 items of 77 documents
Conceptual design of the TRACE detector readout using a compact, dead time-less analog memory ASIC
2015
[EN] The new TRacking Array for light Charged particle Ejectiles (TRACE) detector system requires monitorization and sampling of all pulses in a large number of channels with very strict space and power consumption restrictions for the front-end electronics and cabling. Its readout system is to be based on analog memory ASICs with 64 channels each that sample a View the MathML source window of the waveform of any valid pulses at 200 MHz while discarding any other signals and are read out at 50 MHz with external ADC digitization. For this purpose, a new, compact analog memory architecture is described that allows pulse capture with zero dead time in any channel while vastly reducing the tota…
Optimization on ports activation towards energy efficient data center networks
2018
Nowadays, Internet of thing including network support (i.e. checking social media, sending emails, video conferencing) requires smart and efficient data centers to support these services. Hence, data centers become more important and must be able to respond to ever changing service requirements and application demands. However, data centers are classified as one of the largest consumers of energy in the world. Existing topologies such as ScalNet improves the data center scalability while leading to enormous amounts of energy consumption. In this paper, we present a new energy efficient algorithm for ScalNet called Green ScalNet. The proposed topology strikes a compromise between maximizing …
New Power Conditioning System for Battery-free Satellite Buses with Maximum Power Point Tracking
2007
The purpose of this paper is describe a new conception of Power Conditioning Unit (PCU) developed to fulfill the requirements of BepiColombo Electronic Propulsion module. This load bus has very tough specification especially regarding transient response during total load switch-off ("beam out") which has to be less than 2% of the bus voltage. The conception we propose, is the new Sequential Switching Shunt Maximum Power Regulator (S3MPR) consisting in a S3R, to keep the SA voltage at its Maximum Power Point (MPP) followed by a Boost regulator to produce a constant 100V to supply the Electronic Propulsion (EP). This concept may also be of interest for other future missions involving high pow…
Optimized design of high power density EMI filters for power electronic converters
2016
Nowadays, power density of power converters and related EMI filters is gaining more and more attention. This severely impacts on the design constraints in several application domains. A conventional design of the EMI filter does not guarantee the selection of components/configuration leading to the best power density. For this reason, an optimized design procedure of discrete EMI filters in terms of power density is proposed in this paper. It is based on a previously developed rule-based design procedure, introducing here additional features to obtain a more effective optimization of EMI filter's power density. The proposed approach has been validated in terms of EMI filter's performance an…
Medium Voltage Smart Grid: Experimental Analysis of Secondary Substation Narrow Band Power Line Communication
2013
This paper is focused on the possibility of employing narrow band power line communication (PLC) in medium voltage (MV) distribution networks. The topic is investigated by means of both simulations and experimental tests, which were carried out in the distribution network of Ustica Island. In detail, a two-way MV communication was tested between two secondary substations connected by an MV cable power line. Each substation has a by-pass connection at MV bus-bars and an MV/LV oil filled power transformer. In this paper, the MV and the PLC systems under test are described and the experimental tests are presented, which were carried out to evaluate the parameters of the simulation model. The a…
Dynamic performance enhancement of AC/DC PFC boost converters by means of MRAS observers
2015
Controlling a Power Factor Corrected (PFC) boost converter is not a trivial task, because the higher the dynamic performance, the higher is the input current distortion. On the other hand, recent applications of these converters require fast transients in response to disturbances, such as sudden variations of load power, reference voltage and input voltage. Better performance can be obtained adding a feedforward action to the traditional control scheme, using observers to estimate the input voltage and the output current. However, the actual improvement depends on the dynamic performance of the chosen observers. This paper aims at evaluating the applicability and the performance of differen…
Comparison of power quality impact of different photovoltaic inverters- the viewpoint of the grid
2005
This paper presents the results of an experimental analysis performed with the aim of evaluating the effect of many photovoltaic plants on power quality of the grid. Several parameters as voltage and current distortion, flicker, voltage variations at fundamental frequency and power factor have been observed. The measured values have been compared with the limits reported in the standards and, when possibiIe, their dependence on the characteristics of the grid in terms of its impedance has been pointed out.
Soft switched interleaved boost converters used as high-power battery discharge regulator for space power systems
2004
In the following years the telecommunication satellites will have a much greater power demand than nowadays. One reason for this is that the geostationary orbit required by this kind of satellites is becoming too crowded. Probably power levels of l0 kW to l00 kW will be the standard and with life duration of 25 years. It is not possible to keep 0.5 kW modules with more than 100 in parallel and therefore higher power modules (5 kW) must be used. A higher bus voltage seems also necessary and keeping a safety limit of 150 V, any voltage below it and above 100 V could meet the needs. In this paper we will propose a topology that fits the application: two soft switched interleaved boost converte…
Controlled Fault-Tolerant Power Converters for Power Quality Enhancement
2013
Power quality depends generally on the interaction of electrical power with electrical equipments. If electrical equipments operate correctly and reliably without being damaged or stressed, a suitable level of power quality is assured. On the other hand, if the electrical equipment malfunctions, is unreliable, or is damaged during normal usage, power quality is poor and probably the economical loss could be important like the technical one. In the scenario of the Distributed Generation, power quality issues will be moreover important because an higher dissemination of power conditioning equipment will be requested and this obviously increases the sources of vulnerability of the electrical s…
Design of Bilateral Switched Reluctance Linear Generator to Convert Wave Energy: Case Study in Sicily
2013
The aim of this work is a case study of the adaptation bilateral switched reluctance linear generator to the exploitation of energy of the sea. This type of generator can be used to convert wave energy in electrical energy. In this paper we present an analytical sizing and FEM simulation. As for the results, analysis of the data extracted through the simulations it was possible to calculate the emf. The emf was calculated in two cases of motion of the slider: first hypothesis has set the constant speed while the second is a variable speed according to the law of an oscillatory motion of the sea.