Search results for "T wave"

showing 4 items of 94 documents

The electrocardiographic ‘triangular QRS-ST-T waveform’ pattern : a marker of severe haemodynamic compromise in Takotsubo syndrome : a case report

2020

Abstract Background Takotsubo cardiomyopathy is characterized by transient regional systolic dysfunction of the left ventricle, mimicking myocardial infarction. Although systolic left ventricular (LV) function normalizes in most cases, the outcome is not always favourable. Recently, a rare electrocardiogram (ECG) finding, lambda wave ST elevation or ‘triangular QRS-ST-T waveform’, was suggested as a possible marker of poor outcome in Takotsubo patients Case summary After a brief episode of chest pain and shortness of breath, a 67-year-old woman developed cardiogenic shock. Her resting ECG showed widespread ST elevations, which soon evolved into a pattern of triangular QRS-ST-T waveforms in …

medicine.medical_specialtyST elevationCardiomyopathyCase Reports030204 cardiovascular system & hematologyChest pain03 medical and health sciencesQRS complextapaustutkimus0302 clinical medicineInternal medicineT waveCase reportkardiogeeninen sokkimedicinecase report030212 general & internal medicineMyocardial infarctionCoronary heart disease (incl. Cardiac Intervention)cardiovascular diseasessydäntauditEKGCardiogenic shockTakotsuboHigh-risk ECGEjection fractionbusiness.industryCardiogenic shockST elevationhigh-risk ECGcardiogenic shockmedicine.diseaseCardiologymedicine.symptomQRS-ST-T waveformCardiology and Cardiovascular Medicinebusiness
researchProduct

An uncommon clinical picture: Wellens’ syndrome in a morbidly obese young man

2010

A 39-year-old man presented to the emergency department (ED) of the ‘‘Paolo Giaccone’’ Academic Hospital, Palermo (Italy). He had anterior chest pain that did not radiate to the neck or arms. The patient came from home where the chest pain initiated. The patient was morbidly obese (BMI 54 kg/m). At the ED, the patient’s blood pressure was 120/80 mmHg, the serum troponin I concentration was 0.029 ng/ml (normal values \ 0.034, borderline 0.034–0.12), myoglobin 45 ng/ml (normal values \ 120). While experiencing chest pain, the patient underwent a standard 12 lead electrocardiogram (ECG) that was normal. An echocardiogram, also during the chest pain, excluded the presence of hypo-akinetic left …

medicine.medical_specialtySettore MED/09 - Medicina InternaUnstable anginabusiness.industryWellens' SyndromeWellens' syndromemedicine.diseaseChest painacute coronary syndrome; Wellens' SyndromeSettore MED/45 - Scienze Infermieristiche Generali Cliniche E PediatricheSettore MED/11 - Malattie Dell'Apparato Cardiovascolareacute coronary syndromeStenosisEndocrinologyAnterior chestInternal medicineT waveEmergency MedicineInternal MedicinemedicineCardiologyST segmentMyocardial infarctionmedicine.symptombusinessInternal and Emergency Medicine
researchProduct

Optical quality of hyperopic and myopic phakic intraocular lenses

2013

Aims: To assess and compare the optical quality of the myopic and hyperopic implantable collamer lens (ICL) from its wavefront aberrations for different powers and pupil diameters. Settings and Design: Prospective study. Material and Methods: The wavefront aberrations of two myopic (−3 and −6 diopters (D)) and two hyperopic V4b ICLs (+3 and +6D) were measured in vitro . To assess and compare the optical quality of different powers of ICLs, we analyzed the root mean square (RMS) of total higher order aberrations (HOAs), trefoil, coma, tetrafoil, secondary astigmatism, and spherical aberration at 3- and 4.5-mm pupil. In addition, the point spread functions (PSFs) of each ICL evaluated were ca…

steep corneal curvatureintravitreallacrimal fossaRefractive errorvisual acuitygenetic structurespterygium surgerystandard automated perimetryComa (optics)BlindnessPhakic intraocular lenslaw.inventionsubconjunctival bevacizumab injectionCorneaLens Implantation Intraocularlcsh:Ophthalmologylawmodified deep anterior lamellar keratoplastyMitomycin CMaterials TestingAutogenous tissue graftingProspective StudiesDioptreoptical qualityshort wave automated perimetryexcimer lasernon-proliferative diabetic retinopathyMean deviationin vitroheavy silicone oilBevacizumabLens (optics)Aberrations of the eyeSpherical aberrationHyperopiaAntimicrobial effectOriginal ArticleTriamcinolone acetonidehuman trabecular meshwork cellsPhakic Intraocular Lensesmedicine.medical_specialtyImaging in glaucomadisability evaluationconventional silicone oiltriamcinoloneProsthesis DesignKeratoconusphotorefractive keratectomyOphthalmologygrowth factorsmedicineHumansmyopiamyopic implantable collamer lensshort fluctuationsWavefrontmacular edemaoptical coherence tomographyendophthalmitis agentsbusiness.industrybranch retinal vein occlusionretinal nerve fiber layerpterygium recurrencemedicine.diseaseeye diseasesOphthalmologypediatricwavefront aberrationsquality of lifelcsh:RE1-994bypass surgeryHyperopic implantable collamer lenslacrimal drainage systemsense organsbusinessIndian Journal of Ophthalmology
researchProduct

Tanatologičeskaâ problematika v povesti "Zlaâ večnostʹ" Georgiâ Peskova

2018

Pod pseudonimem Gieorgij Pieskow ukrywała się Elena Dejsza, przedstawicielka „młodszego pokolenia” pisarzy pierwszej fali emigracji rosyjskiej, autorka opowieści Zła wieczność (1932). W utworze istotne miejsce zajmuje problematyka tanatologiczna. Rozpatrywana jest ona w różnych aspektach: poruszany jest tu problem samobójstwa, odbieranego jako zwycięstwo nad śmiercią; sporo miejsca poświęca się immortologii — bibliotekarz ma obsesję na punkcie nieśmiertelności; zwraca się także uwagę na starzenie się jako zjawisko towarzyszące umieraniu; dokonuje się też zabójstwa. W sferze ideowo-tematycznej poruszany jest problem zagłady cywilizacji europejskiej. Na tanatologię artystyczną Gieorgija Piesk…

topic of deathtwórczość Gieorgija PieskowaOswald Spenglerpierwsza fala emigracji rosyjskiejtemat śmierciGeorgii Peskov’s literary outputfirst wave of Russian emigrationnovel Bad Eternityopowieść Zła wiecznośćActa Universitatis Wratislaviensis Slavica Wratislaviensia
researchProduct