Search results for "TECNICA"
showing 10 items of 2886 documents
Space Charge Measurement under DC and DC Periodic Waveform
2018
In High Voltage systems, Partial Discharges (PDs) monitoring are one of the main diagnostic instrument to evaluate the reliability of the apparatus. Under Alternating Current (AC) stress, PDs detection and recognition techniques are well consolidated. On the contrary, the monitoring of PDs under Direct Current (DC) stress is difficult due to complexities related to the nature of the phenomenon, which cause the beginning of PDs events in proximity of the dielectric breakdown. This problem has been partially overcome by using a continuous Periodic waveform (DCP) with positive average value, as described in a recent published work. Under DC stress, another degradation factor is the Space Charg…
Space Charges and Partial Discharges Simultaneous Measurements under DC Stress
2016
In the field of HVDC, the main causes of insulation aging are due to the space charge and PD phenomena. In particular, the purpose of the present work is to verify a possibility to measure simultaneously the space charge and the PDs under DC stress in order to evaluate the correlation between both phenomena. The space charge was measured by using a modified PEA cell and PDs were measured by using a novel wireless sensor system. The space charge profile and the PD pulses carried out simultaneously have been reported and discussed.
Partial discharge of gel insulated high voltage power modules subjected to unconventional voltage waveforms
2016
Performances and duration of the new generation of high voltage power electronic components are dependent on dielectric materials aim to insulating their internal terminals. The presence of defects, some due to faults generated during the manufacturing process, but also due to the internal design of layers and connections, can cause local enhancements of electric field and consequently possible activity of partial discharges phenomena or other effects (aging, tracking) that may result in reduction of device reliability. Furthermore, the usage of unconventional voltage waveforms, like square waves or pulse width modulated waves, additionally increases the electrical aging of the insulation s…
Partial discharge detection and localization along medium voltage cables
2017
In the last years different partial discharge (PD) measuring techniques have been developed because PD diagnostic is the most widely tool to evaluate the insulation condition of a power cable. Recently non-conventional methods and sensors have been used in order to reach improved results in PD measurements. The purpose of this work is to perform measurements that allow to study the variation of pulses when they travel along a MV cable and to locate the pulse source through the time arrival difference of the pulses obtained from two sensors installed separately.
Deformation of bubbles in silicon gel insulation under an alternating electric field
2019
The behavior of silicone gel under electrical stress plays a significant role in the reliability and durability of high voltage electronic power devices due to its widespread use for the insulation of IGBT modules and other components. The charges accumulation at the bubble boundaries leads to significant displacements due to the establishment of Coulombic forces and the high deformability of colloidal system. The main purpose of this work is to validate a numerical approach useful to investigate, for a given silicone gel, the non-linear relation between the applied HVDC stress and the electric field over an air bubble within the insulation bulk. The analysis has been carried out by means o…
Measuring rain energy with the employment of “Arduino”
2016
This paper presents the performances of rainfall energy harvesting through the use of a piezoelectric transducer and an Arduino-based measuring system. Diverse studies agree on the possibility of generating electricity from rainfall, but to date, a study that can measure the quantity of energy produced during rainfall is still missing. The present study begins with results obtained from laboratory researchers using piezoelectric transducers and oscilloscopes — to measure the energy produced from a single raindrop — and concludes with an ad hoc Arduino-based measuring system, aimed at measuring the actual amount of electrical energy produced by a piezoelectric transducer that is exposed to r…
The Acoustic Wave Behavior Within the PEA Cell for Space Charge Measurement
2018
In order to evaluate the acoustic wave behavior within the Pulsed Electro Acoustic (PEA) cell, a simulation model has been developed in this work. The model, implemented in Matlab environment, is based on the analogy between acoustic and electrical quantities. Therefore, it was possible to model the PEA cell as cascade connected lossy transmission lines. The model has been validated theoretically by making a comparison with a simulation result found in literature. The experimental validation has also been made by using the PEA cell of the LEPRE high voltage lab. In addition, four graphs have been realized. Two of them can be used to establish in easy and fast way to obtain the minimum groun…
A Planar Generator for a Wave Energy Converter
2019
This article presents a permanent magnet planar translational generator which is able to exploit multiple modes of sea wave energy extraction. Linear electrical generators have recently been studied for the exploitation of sea wave energy, but, to the best of our knowledge, no synchronous planar translational generator has been proposed. In this article, to maximize the energy extraction, we have considered all the potential modes of motion due to wave excitation and included them within the mathematical model of the proposed system. The principle of operation of the generator can be summarized as follows: the moving part (translator) of the generator is driven from the sea waves and induce…
The Role of Right Interpretation of Space Charge Distribution for Optimized Design of HVDC Cables
2019
In the field of high-voltage transmission systems, different degradation phenomena affect the reliability of the employed components. In particular, under dc stress, the space charge accumulation phenomenon is believed to be the most responsible of the dielectrics lifetime reduction. To measure the accumulated space charges in flat specimens, the pulsed electro-acoustic (PEA) method is one of the most used techniques. The working principle of the PEA cell is based on the acoustic waves propagation and detection. As is well known, the acoustic waves propagating in different means are partially transmitted and partially reflected. Therefore, the piezoelectric sensor of the PEA cell is subject…
Investigation on partial discharges in HVDC cables after polarity reversal events
2020
Due to the accumulation of space charge inside the insulating layer of HVDC cables, the electric field under load conditions may be altered compared to what is established in HVAC cables. For example, a high thermal gradient leads to the inversion of the electric field pattern until the maximum value is reached in proximity of the dielectric-semicon interfaces. These maximum values can be further increased due to transient overvoltages and polarity reversal events until reaching electric field values higher than the rated ones. The main goal of this research is to investigate the possibility that, during these transient phenomena, conditions are created that favor the occurrence of partial …