Search results for "TRACKING"
showing 10 items of 709 documents
Implementation of theP¯ANDA Planar-GEM tracking detector in Monte Carlo simulations
2018
Abstract The P ¯ ANDA experiment at FAIR will be performed to investigate different aspects of hadron physics using anti-proton beams interacting with a fixed nuclear target. The experimental setup consists of a complex series of detector components covering a large solid angle. A detector with a gaseous active media equipped with gas electron multiplier (GEM) technique will be employed to measure tracks of charged particles at forward direction in order to achieve a high momentum resolution. In this work, a full setup of the GEM tracking detector has been implemented in the P ¯ ANDA Monte Carlo simulation package (PandaRoot) based on the current technical and conceptual design, and the exp…
High Voltage Monolithic Active Pixel Sensors
2018
Ever higher demands on resolution and rate capability drive the development of particle tracking detectors. Especially at low momenta, multiple Coulomb scattering in the material of the detector is also strongly affecting the resolution of momentum measurements. While gas-based detectors such as drift chambers and time projection chambers can be built with very small amounts of material, their rate capability is limited by ageing and space charge effects. Hybrid semiconductor detectors on the other hand combine a depleted (silicon) sensor with a custom amplifier and readout chip. Pixelated devices especially can operate efficiently in very harsh rate and radiation environments such as the i…
Performance of a gamma-ray tracking array: Characterizing the AGATA array using a 60Co source
2017
International audience; The AGATA (Advanced GAmma Tracking Array) tracking detector is being designed to far surpass the performance of the previous generation, Compton-suppressed arrays. In this paper, a characterization of AGATA is provided based on data from the second GSI campaign. Emphasis is placed on the proper corrections required to extract the absolute photopeak efficiency and peak-to-total ratio. The performance after tracking is extracted and GEANT4 simulations are used both to understand the results and to scale the measurements up to predicted values for the full 4π implementation of the device.
Particle tracking in kaon electroproduction with cathode-charge sampling in multi-wire proportional chambers
2011
Abstract Wire chambers are routinely operated as tracking detectors in magnetic spectrometers at high-intensity continuous electron beams. Especially in experiments studying reactions with small cross-sections the reaction yield is limited by the background rate in the chambers. One way to determine the track of a charged particle through a multi-wire proportional chamber (MWPC) is the measurement of the charge distribution induced on its cathodes. In practical applications of this read-out method, the algorithm to relate the measured charge distribution to the avalanche position is an important factor for the achievable position resolution and for the track reconstruction efficiency. An al…
A Tracking and Timing (t-and-t) Front-end Electronics For Rpc Detectors
1992
Abstract The availability of a detector such as an RPC (resistive plate counter) opens new possibility on the future experiments for accelerator and non-accelerator physics. The main advantage consists on the possibility to obtain accurate tracking and timing with a low-cost detector and electronics. We report results on time resolution, signal transmission on long strips, efficiency and maintenance. A possible front-end electronics able to give tracking and timing information on each input channel operating in free-running mode will be illustrated toghether to the preliminary tests performed.
Efficiency studies for a tracking detector based on square 1.5m long scintillating fibers read out by SiPM
2009
Abstract A tracking detector based on 1.5 m long scintillating fibers is being developed for the electron arm of the KAOS spectrometer at the Mainz Microtron MAMI. Measurements on light attenuation, particle detection efficiencies and accidental coincidence rates with a prototype set-up using 2 × 2 mm 2 fibers read out by silicon photomultipliers (SiPM) are presented. The highest efficiency at the lowest accidental coincidence rate was reached for high trigger thresholds at the largest SiPM bias voltages. The influence of signal attenuation and dispersion on detection efficiencies is discussed. The results are in good agreement with a Monte Carlo model that was used to predict detector char…
Triple GEM tracking detectors for COMPASS
2002
The small area tracker of COMPASS, a high-luminosity fixed target experiment at CERN's SPS, includes a set of 20 large-size ($31\times 31\,\cm^2$) Gas Electron Multiplier (GEM) detectors. Based on gas amplification in three cascaded GEM foils, these devices permit to obtain high gain and good spatial resolution even at very high particle fluxes. A two-coordinate projective readout yields, for each track, highly correlated signal amplitudes on both projections, allowing to resolve multiple hits in high occupancy regions close to the central deactivated area of $5\,\cm$ diameter. At the same time the material exposed to the beam is minimized. Splitting the amplification in three cascaded stag…
STUDIES OF WIRE GAIN AND TRACK DISTORTION NEAR THE SECTOR EDGES OF THE ALEPH TIME PROJECTION CHAMBER
1986
Abstract The materials used to hold the wires at the sector edges in a large Time Projection Chamber (TPC) inrtoduce distortions of the electric drift field near those edges. These distortions degrade tracking information and sometimes cause large changes in wire gain near the edge. We have studied these two problems for the ALEPH TPC and have found that both can be greatly reduced by the addition of two field correction strips held at appropriate voltages.
PERFORMANCE OF THE ALEPH TIME PROJECTION CHAMBER
1991
The performance of the ALEPH Time Projection Chamber (TPC) has been studied using data taken during the LEP running periods in 1989 and 1990. After correction of residual distortions and optimisation of coordinate reconstruction algorithms, single coordinate resolutions of 173-mu-m in the azimuthal and 740-mu-m in the longitudinal direction are achieved. This results in a momentum resolution for the TPC of DELTA-p/p2 = 1.2 x 10(-3) (GeV/c)-1. In combination with the ALEPH Inner Tracking Chamber (ITC), a total momentum resolution of DELTA-p/p2 = 0.8 x 10(-3) (GeV/c)-1 is obtained. With respect to particle identification, the detector achieves a resolution of 4.4% for the measurement of the i…
Longitudinal phase space reconstruction for a heavy ion accelerator
2020
At the GSI Helmholtzzentrum f\"ur Schwerionenforschung (GSI) in Darmstadt, Germany, a prototype cryomodule (advanced demonstrator) for the superconducting (SC) continuous wave (CW) Helmholtz Linear Accelerator (HELIAC) is under construction. A transport line, comprising quadrupole lenses, rebuncher cavities, beam correctors, and adequate beam instrumentation has been built to deliver the beam from the GSI 1.4 MeV/u High Charge Injector (HLI) to the advanced demonstrator, which offers a test environment for SC CW multigap cavities. In order to achieve proper phase space matching, the beam from the HLI must be characterized in detail. In a dedicated machine experiment the bunch shape has been…