Search results for "TRIMETHYLAMINE"
showing 10 items of 31 documents
Seafood freshness determination through vapour phase Fourier transform infrared spectroscopy.
2006
Abstract A new vapour-phase manifold has been developed to determine trimethylamine (TMA) in fish and cephalopod samples by Fourier transform infrared (FT-IR) spectroscopy. Samples were treated off-line for 1 h with trichloroacetic acid (TCA), filtered and washed. The obtained extracts were aspirated and alkalinized with NaOH 2.0 M, in an on-line system. TMA was separated from the solution in a gas phase separator and then transported by means of a nitrogen carrier into a home made 10 cm pathlength IR gas cell, where the corresponding FT-IR spectra were acquired by accumulating 30 scans per spectrum with 2 cm−1 nominal resolution. The method was applied to the determination of TMA in natura…
Separation, isolation and stereochemical assignment of imazalil enantiomers and their quantitation in an in vitro toxicity test
2016
A simple method for the separation of the enantiomers of the fungicide imazalil was developed. Racemic imazalil was separated into its enantiomers with an enantiomeric purity of 99% using HPLC-UV with an enantioselective column (permethylated cyclodextrin) operated in reversed phase mode (water with 0.2% trimethylamine and 0.08% acetic acid and methanol). The absolute configuration of the separated enantiomers was assigned and unequivocally confirmed by optical rotation as well as by vibrational circular dichroism (VCD) and electronic circular dichroism (ECD) combined with ab-initio calculations. The same enantioselective column was also used to develop an HPLC-MS/MS method for the quantifi…
Properties of trialkylamines as catalysts of resoles synthesis
2000
A series of the syntheses of phenol–formaldehyde resoles was carried out in the presence of trimethyl-, triethyl-, tripropyl-, and tributylamines and sodium hydroxide as catalysts for this process. The rate constants were calculated for the partial reactions identified in the synthesis. Also, the performance properties of the resins obtained and the hardened resin samples were estimated in simple tests. © 2000 John Wiley & Sons, Inc. J Appl Polym Sci 77: 898–902, 2000
Liquid chromatographic determination of trimethylamine in water.
2004
A method for the selective determination of trimethylamine (TMA) in aqueous matrices by liquid chromatography is reported. The proposed procedure is based on the derivatization of the analyte with 9-fluorenylmethyl chloroformate (FMOC) in a precolumn (Hypersil C18, 30 microm, 20 mm x 2.1 mm i.d.) connected on-line to the analytical column (LiChrosphere 100 RP18, 5 microm, 125 mm x 4 mm i.d.). Gradient elution was performed with a mixture of acetonitrile-water-0.05 M borate buffer (pH 9.0). The method has been applied to the direct determination of TMA in water within the 0.25-10.0 microg/ml concentration interval, and can also be adapted to the determination of TMA over the range 0.05-1.0 m…
Comparative study of the determination of trimethylamine in water and air by combining liquid chromatography and solid-phase microextraction with on-…
2005
This work describes a new approach for the determination of trimethylamine (TMA) in water and air by liquid chromatography (LC). The assay is based on the employment of a solid-phase microextraction (SPME) fiber for sampling and for derivatization of the analyte with the fluorogenic reagent 9-fluorenylmethyl chloroformate (FMOC). The fiber, with a Carbowax-templated resin -50mum coating, was first immersed into a solution of the reagent. Once loaded with the reagent, the fiber was immersed into the water samples or exposed to the air samples in order to extract and to derivatize the analyte. Finally, the fiber was placed into a HPLC-SPME interface to desorb and transfer the TMA-FMOC derivat…
Description and commissioning of NEXT-MM prototype: first results from operation in a Xenon-Trimethylamine gas mixture
2014
[EN] A technical description of NEXT-MM and its commissioning and first performance is reported. Having an active volume of ∼35 cm drift × 28 cm diameter, it constitutes the largest Micromegas-read TPC operated in Xenon ever constructed, made by a sectorial arrangement of the 4 largest single wafers manufactured with the Microbulk technique to date. It is equipped with a suitably pixelized readout and with a sufficiently large sensitive volume (∼23 l) so as to contain long (∼20 cm) electron tracks. First results obtained at 1 bar for Xenon and Trymethylamine (Xe-(2%)TMA) mixture are presented. The TPC can accurately reconstruct extended background tracks. An encouraging fu…
Optical sensing responses of CrIIICl(TPP)(H2O)-based coatings obtained by an atmospheric pressure plasma method – Application to the detection of vol…
2014
Food spoilage processes are a considerable concern for both the food industry and the consumer, due to financial, food quality and food safety aspects. A primary issue is the prevention/monitoring of the formation of biogenic and volatile amines, such as occurring in fish and in other microbiologically unstable food items rich in proteins, produced by e.g. oxidative decarboxylation of amino acids. One strategy for their monitoring is the development of films with colorimetric sensing properties that are able to indicate food spoilage. The aim of this investigation was the development of a novel metalloporphyrin-based coating allowing the sensitive detection of typical volatile amines, such …
Characterization of a medium size Xe/TMA TPC instrumented with microbulk Micromegas, using low-energy gamma-rays
2014
NEXT-MM is a general-purpose high pressure (10 bar, $\sim25$ l active volume) Xenon-based TPC, read out in charge mode with an 8 cm $\times$8 cm-segmented 700 cm$^2$ plane (1152 ch) of the latest microbulk-Micromegas technology. It has been recently commissioned at University of Zaragoza as part of the R&D of the NEXT $0\nu\beta\beta$ experiment, although the experiment's first stage is currently being built based on a SiPM/PMT-readout concept relying on electroluminescence. Around 2 million events were collected during the last months, stemming from the low energy $\gamma$-rays emitted by a $^{241}$Am source when interacting with the Xenon gas ($\epsilon$ = 26, 30, 59.5 keV). The localized…
Diabetes is Associated with Higher Trimethylamine N-oxide Plasma Levels
2016
Recent studies have revealed strong associations between systemic trimethylamine N-oxide (TMAO) levels, atherosclerosis and cardiovascular risk. In addition, plasma L-carnitine levels in patients with high TMAO concentrations predicted an increased risk for cardiovascular disease and incident major adverse cardiac events. The aim of the present study was to investigate the relation between TMAO and L-carnitine plasma levels and diabetes. Blood plasma samples were collected from 12 and 20 weeks old db/db mice and patients undergoing percutaneous coronary intervention. Diabetic compared to non-diabetic db/L mice presented 10-fold higher TMAO, but lower L-carnitine plasma concentrations at 12 …
Plasma trimethylamine-N-oxide and related metabolites are associated with type 2 diabetes risk in the Prevención con Dieta Mediterránea (PREDIMED) tr…
2018
Background The role of trimethylamine-N-oxide (TMAO) in type 2 diabetes (T2D) is currently partially understood and controversial. Objective The aim of this study was to investigate associations between TMAO and related metabolites with T2D risk in subjects at high risk of cardiovascular disease. Design This is a case-cohort design study within the Prevencion con Dieta Mediterranea (PREDIMED) study, with 251 incident T2D cases and a random sample of 694 participants (641 noncases and 53 overlapping cases) without T2D at baseline (median follow-up: 3.8 y). We used liquid chromatography-tandem mass spectrometry to measure plasma TMAO, l-carnitine, betaine, lyso-phosphatidylcholine (LPC) and l…