Search results for "Tact"
showing 10 items of 1313 documents
Decay properties of 114Ag
1971
Absence of delayed fission in the? ?-decay of 2.3 min238Pa
1985
We have searched for beta-delayed fission in the decay of 2.3 min238Pa produced in the238U(n,p) reaction with 14.7 MeV neutrons. Through microprocessor-controlled chemical separations of protactinium about 109 atoms of238Pa were isolated and exposed to fission track detectors. From the absence of fission tracks an upper limit for the betadelayed fission probability of238Pa, i.e.Pβf<2.6 10−8, is obtained at 95% confidence level. This rules out positive evidence for this decay mode of238Pa reported elsewhere. Simple theoretical estimates ofPβf range from 10−7 to 10−9.
A rescaling algorithm for the numerical solution to the porous medium equation in a two-component domain
2016
Abstract The aim of this paper is to design a rescaling algorithm for the numerical solution to the system of two porous medium equations defined on two different components of the real line, that are connected by the nonlinear contact condition. The algorithm is based on the self-similarity of solutions on different scales and it presents a space-time adaptable method producing more exact numerical solution in the area of the interface between the components, whereas the number of grid points stays fixed.
Active macro-zone approach for incremental elastoplastic-contact analysis
2013
SUMMARY The symmetric boundary element method, based on the Galerkin hypotheses, has found an application in the nonlinear analysis of plasticity and in contact-detachment problems, but both dealt with separately. In this paper, we want to treat these complex phenomena together as a linear complementarity problem. A mixed variable multidomain approach is utilized in which the substructures are distinguished into macroelements, where elastic behavior is assumed, and bem-elements, where it is possible that plastic strains may occur. Elasticity equations are written for all the substructures, and regularity conditions in weighted (weak) form on the boundary sides and in the nodes (strong) betw…
Recent advances in the application of pulsed light processing for improving food safety and increasing shelf life
2019
Abstract Background New technologies of non-thermal disinfection such as pulsed light (PL) have emerged lately as an alternative to traditional (thermal and chemical) disinfection and preservation methods. PL can be used to decontaminate a great variety of foods as well as to decontaminate contact surfaces, thus improving safety in foods and extending their shelf life. Moreover, this technology can prevent or reduce some of the detrimental effects of traditional methods on nutrients and bioactive compounds of food products. Scope and approach The combination of PL with other techniques such as ultraviolet light (UV), thermosonication (TS), pulsed electric fields (PEF), manothermosonication …
Screening contact allergens from cosmetics using an optical biosensor
2006
S3 Guidelines: Epicutaneous patch testing with contact allergens and drugs – Short version, Part 2
2019
Epicutaneous patch testing is the diagnostic standard for the detection of allergic contact dermatitis. The present guidelines are aimed at residents and board-certified physicians in the fields of dermatology and allergology as well as other medical specialties involved in establishing the indication for patch testing and its execution in patients with contact dermatitis and other forms of delayed-type hypersensitivity. The target audience also includes other health care providers and insurance funds. Based on a systematic literature search and a formal consensus process (S3), the guidelines were developed by dermatologists in collaboration with pediatricians, occupational medicine physici…
S3 guidelines: Epicutaneous patch testing with contact allergens and drugs – Short version, Part 1
2019
Epicutaneous patch testing is the diagnostic standard for the detection of allergic contact dermatitis. The present guidelines are aimed at residents and board-certified physicians in the fields of dermatology and allergology as well as other medical specialties involved in establishing the indication for patch testing and its execution in patients with contact dermatitis and other forms of delayed-type hypersensitivity. The target audience also includes other health care providers and insurance funds. Based on a systematic literature search and a formal consensus process (S3), the guidelines were developed by dermatologists in collaboration with pediatricians, occupational medicine physici…
2015
In everyday life, one of the most frequent activities involves accelerating and decelerating an object held in precision grip. In many contexts, humans scale and synchronize their grip force, normal to the finger/object contact, in anticipation of the expected tangential load force, resulting from the combination of the gravitational and the inertial forces. In many contexts, grip force and load force are linearly coupled. A few studies have examined how we adjust the parameters - gain and offset - of this linear relationship. However, the question remains open as to how the brain adjusts grip force regardless of whether load force is generated by different combinations of weight and inerti…
Effect of a Passive Tuned Mass Damper on Offshore Installation of a Wind Turbine Nacelle
2021
Abstract Although the installation of offshore wind turbines takes place in calm seas, successful mating of wind turbine components can be challenging due to the relative motions between the two mating parts. This work investigates the effect of a passive tuned mass damper on the mating processes of a nacelle for a 10-megawatt (MW) offshore wind turbine. A nacelle with lifting wires and a monopile with a mass damper are respectively modelled using the multibody formulation in the HAWC2 program. A single mass damper is tuned to target at the first natural period of the monopile and is coupled to the main program using a dynamic link library. Afterwards, numerical simulations were carried out…