Search results for "Tact"
showing 10 items of 1313 documents
Stereotactic Radiotherapy for the Treatment of Patients With Oligo-progressive Metastatic Renal Cell Carcinoma Receiving Vascular Endothelial Growth …
2020
Aim This retrospective observational study evaluated the role of hypo-fractionated stereotactic radiotherapy (SRT) in patients with oligo-progressive metastatic renal cell carcinoma (mRCC) treated with first-line oral tyrosine kinase inhibitors (TKI). Data on local control, delay of further progression, and safety are reported. Patients and methods Between January 2010 and December 2016, 28 patients with mRCC who showed oligo-progressive disease while receiving first-line pazopanib were treated with hypofractionated SRT to progressive metastatic sites to delay the change of systemic therapy. First and second progression-free survival (PFS-1 and PFS-2) were recorded, as well as objective res…
Necrológica - En memoria de Ángel Trapero: Un republicano de base
2006
Power profiles in multifocal contact lenses with variable multifocal zone
2016
BACKGROUND The power profile of multifocal contact lenses has been demonstrated to report important information that could be used during the fitting process. The aim of this work is to describe the power profile of a recent set of gas permeable multifocal contact lenses as a function of the pupil radius. METHODS The measured multifocal contact lenses have a centre-distance design, and are available with five distance-vision diameters (XS, S, M, L and XL) and two different additions: Type A (up to +2.00 D) and Type B (up to +2.50 D). The optical device NIMO TR1504 (Lambda-X, Nivelles, Belgium) was used to obtain the power profile measurements. The optical lens power distribution as a functi…
Oxygen permeability of hydrogel contact lenses with organosilicon moieties
2002
Oxygen transport through two extended wear (day and night) hydrogel contact lenses that contain organosilicon moieties (balafilcon A and lotrafilcon A) was studied in the hydrate (hydrogel) and dry (xerogel) states. The water uptake increased the oxygen permeability [(Dk)app] and transmissibility [Dk/L(av)] coefficients of the dry materials by about 70%. The (Dk)app for the hydrated lenses was determined following the so-called stack procedure. The values obtained were 107 +/- 4 barrer for balafilcon A and 141 +/- 5 barrer for lotrafilcon A, about 5-10 times larger than those previously reported for conventional (without organosilicon moieties) extended wear hydrogels contact lenses. The Dk…
Power Profiles and In Vitro Optical Quality of Scleral Contact Lenses: Effect of the Aperture and Power
2017
To assess the power profile and in vitro optical quality of scleral contact lenses with different powers as a function of the optical aperture. The mini and semiscleral contact lenses (Procornea) were measured for five powers per design. The NIMO TR-1504 (Lambda-X) was used to assess the power profile and Zernike coefficients of each contact lens. Ten measurements per lens were taken at 3- and 6-mm apertures. Furthermore, the optical quality of each lens was described in Zernike coefficients, modulation transfer function, and point spread function (PSF). A convolution of each lens PSF with an eye-chart image was also computed. The optical power fluctuated less than 0.5 diopters (D) along th…
Optical quality of rotationally symmetrical contact lenses derived from their power profiles.
2017
To present a methodology for evaluating the optical quality of rotationally symmetrical contact lenses (CLs) from a single power profile.Simulated rotationally symmetrical power profiles corresponding to different CLs designs (monofocal, two-zone center-near bifocal, and four-zone center-distance bifocal) were used to calculate the wavefront error profile by means of numerical integration. Then, each lens wavefront error profile was spun around the center to obtain the lens wavefront error surface. From the surface, monochromatic optical transfer functions (OTF), simulated images and the visual Strehl ratio based on the OTF (VSOTF) were obtained for different distances and pupil sizes (3 an…
Evaluating a hierarchical approach to landscape level harvest scheduling
2018
Forest planning at the landscape level has the potential to become a large intractable problem. In Finland, Metsähallitus (the state enterprise that manages federally owned land) creates strategic plans to determine the appropriate harvest level. While these plans are feasible, they are not implementable in practice as the harvests are scattered temporally and spatially. Requiring that harvests be organized both temporally and spatially for practical implementation can result in an intractable problem. Through a hierarchical approach, the problem can be organized into steps in which the intractable problem is broken down into smaller easily solvable parts. As an approximation technique, the…
Organic Thin-Film Transistors with Enhanced Sensing Capabilities
2009
Organic thin-film transistors, used as sensing devices, have been attracting quite a considerable interest lately as they offer advantages such as multi parameter behaviour and possibility to be quite easily molecularly tuned for the detection of specific analytes. Here, a study on the dependences of the devices responses on important parameters such as the active layer thickness and its morphology as well as on the transistor channel length is presented. To introduce the least number of variables the system chosen for this study is quite a simple and well assessed one being based on a thiophene oligomer active layer exposed to 1-butanol vapours.
Supination control increases performance in sideward cutting movements in tennis.
2013
The objective of this study was to explore the effects of tennis shoe characteristics on performance during sideward cutting movements followed by direction changes. Five tennis players (age = 21.5 +/- 0.8 years, mass = 75.2 +/- 2.8 kg, and height = 1.78 +/- 0.05 m) participated in the study and 10 tennis shoes were tested. Several footwear mechanical parameters were analyzed: Shore A hardness, longitudinal and transverse flexibility, midsole height at heel, presence of heel counters, and weight. A force plate was used to measure the kinetic variables, and two video cameras were used to perform a three-dimensional photogrammetric analysis. Results revealed that subject-footwear interaction …
History of materials used for recording static and dynamic occlusal contact marks: a literature review
2011
In the discipline of prosthetic dentistry it is important not only to examine the occlusion, but to be able to record, store, and transfer the information. Over the years many occlusion testing materials have been used. It has been suggested the clinical recording and transfer of information using waxes and other occlusion recording materials have disadvantages relating to inaccuracy and problems of manipulation. Therefore, there has been introduction of many new systems for recording occlusion contacts to overcome such problems. The correct physiological recovery of occlusion posses as much a challenge as ever for every dentist and technician. Even the smallest high spots measuring just a …