Search results for "Tears"
showing 10 items of 102 documents
Differential Effects of Dry Eye Disorders on Metabolomic Profile by 1H Nuclear Magnetic Resonance Spectroscopy
2014
We used1H NMR spectroscopy to analyze the metabolomic profile of reflex tears from patients with dry eye disorders (DEDs). 90 subjects were divided into 2 groups: (1) patients with DEDs (DEDG;n = 55) and (2) healthy subjects (CG;n = 35). Additionally, the DEDG was subdivided into 2 subgroups based on DED severity: mild-to-moderate and moderate (n = 22andn = 33, resp.). Personal interviews and systematized ophthalmologic examinations were carried out. Reflex tears (20–30 μL) were collected by gently rubbing in the inferior meniscus of both eyelids with a microglass pipette and stored at −80°C until analysis. NMR spectra were acquired using a standard one-dimensional pulse sequence with water…
The relative roles of intragenic polymorphisms of the vitamin d receptor gene in lumbar spine degeneration and bone density.
2001
Study Design. A retrospective cohort study. Objectives. To compare the magnitudes of the associations of TaqI polymorphisms of the vitamin D receptor gene with bone density and lumbar spine degeneration in the same sample. Summary of Background Data. Vitamin D receptor gene variations are associated with osteoporosis, osteoarthritis, and disc degeneration. Their role in these conditions remains poorly understood. Methods. Bone density of the spine and femur were determined through DEXA, and lumbar disc degeneration was determined from magnetic resonance imaging assessments of signal intensity, disc narrowing, bulging, anular tears, herniations, and osteophytes. Associations between these me…
Early clinical outcomes after small incision lenticule extraction surgery (SMILE)
2018
Abstract Purpose Dry eye is known to impact on clinical outcomes after laser vision correction and the use of a newer ‘all femtosecond laser’ surgical approach may be associated with less impact on the ocular surface post-operatively. The purpose of this study was to evaluate the early clinical outcomes and tear instability after the first small incision lenticule extraction (SMILE) cases undertaken by three surgeons at a single site in the UK. Methods Retrospective audit. Seventy-one eyes of 37 patients underwent SMILE surgery using the Zeiss VisuMax laser system (Carl Zeiss Meditec, Germany). Uncorrected and corrected distance visual acuity, spherical equivalent refraction, fluorescein en…
Analysis of the Corneal Anterior and Posterior Surface in Patients With Peripheral Hypertrophic Subepithelial Corneal Opacification
2019
PURPOSE To characterize the corneal changes in peripheral hypertrophic subepithelial corneal opacification (PHSCO) considering elevation of the anterior and posterior corneal surface, corneal astigmatism, tear secretion, and endothelial cell density. METHODS Thirty-eight eyes of 22 patients with PHSCO on at least 1 eye and 38 eyes of 22 age- and sex-matched healthy subjects were included in this retrospective cross-sectional study. Using the Pentacam system (Oculus, Wetzlar, Germany), measurement of the anterior and posterior corneal surface was performed. In addition, the Schirmer test was conducted, and endothelial cells were counted in the central cornea with a specular microscope (SP-30…
Evaluating tear clearance rate with optical coherence tomography
2017
Purpose: To assess the early-phase of tear clearance rate (TCR) with anterior segment optical coherence tomography (OCT) and to determine the association between TCR and other clinical measures of the tear film in a group of young subjects with different levels of tear film quality. Methods: TCR was classified as the percentage decrease of the inferior tear meniscus height 30s after instillation of 5uL 0.9% saline solution. Fifty subjects (32F and 18M) aged (mean +/- standard deviation) 25.5 +/- 4.3 years volunteered for the study. It consisted of a review of medical history, Ocular Surface Disease Index (OSDI) questionnaire, tear film osmolarity measurements, slit lamp examination and TCR …
Tear film stability over a myopia control contact lens compared to a monofocal design
2021
Background: To compare the short-term effect of two contact lenses on pre-lens tear film stability and comfort: dual-focus contact lens (MiSight) and a monofocal contact lens (Proclear 1-day).Methods: This randomised, double-masked, crossover study was performed in twenty-eight healthy, myopic volunteers aged between 18 and 32 years (23.5 +/- 4.1 years). Only one randomly chosen eye was assessed. Distance vision and refraction were evaluated at baseline. Each contact lens type (monofocal and dual-focus) was randomly fitted, always in both eyes. A visual analogue scale between 0 and 10 was used to assess general comfort, physical comfort, and visual comfort. Tear Film Surface Quality (TFSQ) …
Systemic, environmental and lifestyle risk factors for dry eye disease in a mediterranean caucasian population
2022
Abstract Objectives To assess systemic, environmental and lifestyle risk factors for dry eye disease (DED) in a Mediterranean Caucasian population. Methods A cross-sectional study was performed on 120 Caucasian participants aged between 18 and 89 years (47.0 ± 22.8 years). Medical history, information regarding environmental conditions and lifestyle, Ocular Surface Disease Index, Dry Eye Questionnaire-5, non-Invasive (Oculus Keratograph 5 M) breakup time, tear film osmolarity and ocular surface staining parameters were assessed in a single clinical session to allow DED diagnosis based on the guidelines of the Tear Film and Ocular Surface Society Dry Eye Workshop II Diagnostic Methodology Re…
Ocular Surface and Tear Film Changes in Older Women Working with Computers
2015
The aim of this work is to investigate changes in the ocular surface (OS) and tear film (TF) by means of questionnaire-based subjective symptoms, TF break-up time, Schirmer test, and TF analysis in women working with computers and to analyze the effects of the oral supplementation with antioxidants/omega 3 fatty acids (A/ω3) in the OS outcomes. Women aged 40–65 years (n=148) were recruited at the Administrative Offices of Valencia (Spain) and distributed into two age groups, 40–52 years (AGE1;n=87) and 53–65 years (AGE2;n=61), and then subdivided according to being (or not) computer users (CUG; NCUG) during the workday. Homogeneous subgroups were randomly assigned (or not) to the daily inta…
OCT for Assessing Artificial Tears Effectiveness in Contact Lens Wearers
2011
PURPOSE: To apply a commercially available high-resolution spectral domain optical coherence tomographer (SOCT) to assess the change in tear volume after application of a new artificial tears formulation specifically developed for contact lens (CL) users. METHODS: Twenty OD from young healthy CL wearers (mean age, 24.7 ± 3.5 years) with refractive errors ranging from -0.75 to -2.50 D (mean, -1.56 ± 0.69 D) were examined. All subjects were fitted with Focus Dailies CL (Ciba Vision), and two drops of Blink Contacts (AMO), lubricating formulation specifically developed for CL wearers, were instilled after baseline measures. Tear meniscus volume (TMV) was measured immediately after and 1 min, 1…
Online Vs In-person Education: Evaluating the Potential Influence of Teaching Modality on Dry Eye Symptoms and Risk Factors During the COVID-19 Pande…
2021
OBJECTIVES: To assess the potential effects of switching to online lecture format on dry eye symptoms and dry eye disease (DED) risk factors. METHODS: An anonymous cross-sectional online survey was conducted in 812 university students (mean age, 21.5±4.0 years). Participants were classified according to the number of hours the participants took online lectures into online students or in-person students. Respondents completed a total of three DED questionnaires (Ocular Surface Disease Index [OSDI]; 5-item Dry Eye Questionnaire; 8-item Contact Lens Dry Eye Questionnaire) and were surveyed on dry eye risk factors contemplated by the Tear Film and Ocular Surface Society Dry Eye Workshop II in a…