Search results for "Technology"
showing 10 items of 30343 documents
Improving the cementation of the tibial component in knee arthroplasty : a study of four techniques in the cadaver.
2021
Aims The main objective of this study is to analyze the penetration of bone cement in four different full cementation techniques of the tibial tray. Methods In order to determine the best tibial tray cementation technique, we applied cement to 40 cryopreserved donor tibiae by four different techniques: 1) double-layer cementation of the tibial component and tibial bone with bone restrictor; 2) metallic cementation of the tibial component without bone restrictor; 3) bone cementation of the tibia with bone restrictor; and 4) superficial bone cementation of the tibia and metallic keel cementation of the tibial component without bone restrictor. We performed CT exams of all 40 subjects, and mea…
Development of the first marmoset-specific DNA microarray (EUMAMA): a new genetic tool for large-scale expression profiling in a non-human primate
2007
Abstract Background The common marmoset monkey (Callithrix jacchus), a small non-endangered New World primate native to eastern Brazil, is becoming increasingly used as a non-human primate model in biomedical research, drug development and safety assessment. In contrast to the growing interest for the marmoset as an animal model, the molecular tools for genetic analysis are extremely limited. Results Here we report the development of the first marmoset-specific oligonucleotide microarray (EUMAMA) containing probe sets targeting 1541 different marmoset transcripts expressed in hippocampus. These 1541 transcripts represent a wide variety of different functional gene classes. Hybridisation of …
Novel Digital Technique to Quantify the Area and Volume of Cement Remaining and Enamel Removed after Fixed Multibracket Appliance Therapy Debonding: …
2020
The aim of this study was to construct a novel, repeatable, reproducible, and accurate measurement protocol for the area and volume of the remaining cement after removal of fixed multibracket appliances, the area and volume of remaining cement after cement removal, the area and volume of enamel removed after cement removal, and the volume of cement used to adhere fixed multibracket appliances. A total of 30 brackets were cemented and removed with over 30 extracted teeth embedded into three experimental models of epoxy resin. The models were scanned before and after bracket placement, bracket debonding, and polishing the remaining cement. The brackets were submitted to micro-computed tomogra…
CMC is more than a measure of corticospinal tract integrity in acute stroke patients
2021
In healthy subjects, motor cortex activity and electromyographic (EMG) signals from contracting contralateral muscle show coherence in the beta (15-30 Hz) range. Corticomuscular coherence (CMC) is considered a sign of functional coupling between muscle and brain. Based on prior studies, CMC is altered in stroke, but functional significance of this finding has remained unclear. Here, we examined CMC in acute stroke patients and correlated the results with clinical outcome measures and corticospinal tract (CST) integrity estimated with diffusion tensor imaging (DTI). During isometric contraction of the extensor carpi radialis muscle, EMG and magnetoencephalographic oscillatory signals were re…
Ultrasound-guided musculoskeletal interventional procedures around the elbow, hand and wrist excluding carpal tunnel procedures.
2021
Ultrasound is a fast, reliable and radiation-free method for the assessment of a wide range of pathological conditions, as well as for the guidance of percutaneous interventional procedures around the elbow, hand and wrist. Intraarticular and periarticular interventional procedures can be easily performed under continuous ultrasound monitoring to ensure correct needle positioning and medication delivery to a specific target. The most common ultrasound-guided procedures performed around the elbow, wrist, and hand are described in this review, excluding carpal tunnel procedures. Specifically, elbow steroid injections are performed in patients with inflammatory disorders, while hyaluronic acid…
Speed-Related Energy Flow and Joint Function Change During Human Walking.
2021
During human walking, mechanical energy transfers between segments via joints. Joint mechanics of the human body are coordinated with each other to adapt to speed change. The aim of this study is to analyze the functional behaviors of major joints during walking, and how joints and segments alter walking speed during different periods (collision, rebound, preload, and push-off) of stance phase. In this study, gait experiment was performed with three different self-selected speeds. Mechanical works of joints and segments were determined with collected data. Joint function indices were calculated based on net joint work. The results show that the primary functional behaviors of joints would n…
MRI findings and evoked potentials in patients with myotonic dystrophy versus facioscapulohumeral dystrophy
1997
Evoked potentials recordings have been applied to many neurological disorders, localizing the lesions in the central nervous system (CNS) pathways. Facioscapulohumeral muscular dystrophy (FSHD) is a slowly progressive degenerative disease involving the muscles of the face and shoulders. On the contrary, myotonic distrophy (MD), the most frequent and severe myotonic disease, is caracterized by myotonia (delay of relaxation after voluntary contraction), muscular atrophy and dystrophic changes in non-muscular tissues. In the present investigation, patients with clinically and electromyographically verified FSHD and MD were examined using somatosensory evoked potentials (SEP) and brainstem aud…
The arterial blood supply of the temporomandibular joint: an anatomical study and clinical implications
2013
Purpose: The aim of this study was to analyze three-dimensional images of the arterial supply to the temporomandibular joint. Materials and Methods: Ten patients (five men and five women, mean age 36 years) without signs or symptoms of temporomandibular disorders, who underwent contrast-enhanced computed tomographic (CT) scanning with intravenous contrast, were studied. The direct volume rendering technique of CT images was used, and a data set of images to visualize the vasculature of the human temporomandibular joint in three dimensions was created. After elaboration of the data through post-processing, the arterial supply of the temporomandibular joint was studied. Results: The analysis …
Evaluation of efficacy and biocompatibility of a new absorbable synthetic substitute as a dural onlay graft in a large animal model.
2016
Numerous dura substitutes are commercially available, but no absorbable synthetic dura repair product has been used for both onlay and suture applications.The safety and effectiveness of a new absorbable synthetic substitute composed of Poly-L-lactide microfibers as onlay dural graft were evaluated.Physical properties and performance of the microfibrous synthetic dural substitute implanted as an onlay or suturable grafts were compared with these commercial products, including CODMAN ETHISORB™ Dura Patch and DuraGen™ Dural Graft Matrix, in a canine duraplasty model. The cerebrospinal fluid (CSF) leakage, macroscopic and microscopic observation at 30 and 90 days after implantation were invest…
Patient-specific computational evaluation of stiffness distribution in ascending thoracic aortic aneurysm
2021
Quantifying local aortic stiffness properties in vivo is acknowledged as essential to assess the severity of an ascending thoracic aortic aneurysm (ATAA). Recently, the LESI (local extensional stiffness identification) methodology has been established to quantify non-invasively local stiffness properties of ATAAs using electrocardiographic-gated computed tomography (ECG-gated CT) scans. The aim of the current study was to determine the most sensitive markers of local ATAA stiffness estimation with the hypothesis that direct measures of local ATAA stiffness could better detect the high-risk patients. A cohort of 30 patients (12 BAV and 18 TAV) referred for aortic size evaluation by ECG-gated…