Abstract The present work was undertaken to investigate the survival of Listeria monocytogenes ATCC 19114T in soil during the whole crop cycle of rocket (Eruca sativa Mill.) and basil (Ocimum basilicum L.), to monitor its transfer to the leaves, and to evaluate its viability at harvest. To this purpose, the soil was N–P–K fertilized and four trials, obtained with different combinations of soil treatment, listerial inoculums and seed planting, were followed for each aromatic plant. Soil was weekly investigated for total microbial counts and L. monocytogenes evolution. At the starting time, un-inoculated autoclaved soil showed a limited microbial load (103 CFU g dw−1), while un-inoculated non…

food.ingredientbiologySoil testInoculationaromatic plantsBasilicumSowingpathogenicErucaListeria monocytogenes; pathogenic; aromatic plantsSettore AGR/04 - Orticoltura E Floricolturabiology.organism_classificationOcimumcomplex mixturesHorticulturefoodBotanyListeriaTemperature gradient gel electrophoresisFood ScienceBiotechnologyListeria monocytogeneSettore AGR/16 - Microbiologia Agraria
researchProduct

Partial Discharges in HVDC Cables - The Effect of the Temperature Gradient During Load Transients

2021

The paper investigates the role of the space charge accumulation phenomena in the inception of Partial Discharges (PD) in a defect within the bulk of the dielectrics of a High Voltage Direct Current (HVDC) cable. It is widespread accepted that the number of PD occurring in an HVDC cable during its lifetime is largely less than that under AC voltage stress. This is essentially due to higher values of the voltage between the conductor and the screen needed to trigger PD under a steady DC voltage than the same value under AC stress. Nevertheless, due to the dependency of the electrical conductivity of the insulation on the electric field and temperature, PD in HVDC cables is strongly influence…

power cable insulationHVDCMaterials sciencepartial discharge (PD)Electric field simulationDirect currentfinite element analysisMechanicsSpace chargeStress (mechanics)Settore ING-IND/31 - ElettrotecnicaTemperature gradientElectrical resistivity and conductivityload transientsTransient (oscillation)Electrical and Electronic EngineeringCurrent (fluid)VoltageIEEE Transactions on Dielectrics and Electrical Insulation
researchProduct

Practical Strategies for Stable Operation of HFF-QCM in Continuous Air Flow

2013

Currently there are a few fields of application using quartz crystal microbalances (QCM). Because of environmental conditions and insufficient resolution of the microbalance, chemical sensing of volatile organic compounds in an open system was as yet not possible. In this study we present strategies on how to use 195 MHz fundamental quartz resonators for a mobile sensor platform to detect airborne analytes. Commonly the use of devices with a resonant frequency of about 10 MHz is standard. By increasing the frequency to 195 MHz the frequency shift increases by a factor of almost 400. Unfortunately, such kinds of quartz crystals tend to exhibit some challenges to obtain a reasonable signal-to…