Search results for "Thermal ionization"
showing 5 items of 55 documents
Development of an Isotope Dilution Mass Spectrometric Method for Dimethylthallium Speciation and First Evidence of Its Existence in the Ocean
1999
A sensitive analytical method for the determination of dimethyl thallium (Me2Tl+) in environmental samples by positive thermal ionization isotope dilution mass spectrometry (PTI-IDMS) was developed...
Principle and analytical applications of resonance lonization mass spectrometry
1989
Resonance ionization mass spectrometry (RIMS) is a very sensitive analytical technique for the detection of trace elements. This method is based on the excitation and ionization of atoms with resonant laser light followed by mass analysis. It allows element and, in some cases, isotope selective ionization and is applicable to most of the elements of the periodic table. A high selectivity can be achieved by applying three step photoionization of the elements under investigation and an additional mass separation for an unambiguous isotope assignment. An effective facility for resonance ionization mass spectrometry consists of three dye lasers which are pumped by two copper vapor lasers and of…
Comparative optical reflection and mass spectrometry analysis of thermodesorption of Langmuir-Blodgett films
1992
Abstract Thermodesorption of cadmium arachidate multilayers is studied by optical surface analysis and by mass spectrometry measurements. The optical reflection technique has been improved to discriminate signal contributions from desorption and light scattering. The scattering arises from film heterogeneities that are also observed by Nomarsky microscopy. The assessment of these heterogeneities is important to understand mass spectrometry data. Both the optical technique and mass spectrometry are sensitive to observing the multilayer phase transition at 110 °C and the desorption near 200 °C (at the heating rate applied). The mass spectrometry analysis yields detailed information on the des…
Towards high-accuracy mass spectrometry of highly charged short-lived ions at ISOLTRAP
2006
Dedicated to H.-J. Kluge on the occasion of his 65th birthday anniversary - Jürgen Kluge Special Issue; Multiply charged ions of stable xenon isotopes from a plasma ion source have been mass-selected by the on-line mass separator ISOLDE/CERN and delivered to the triple-trap mass spectrometer ISOLTRAP. The doubly charged ions that survived the charge-exchange processes during bunching and ion preparation were transferred to a precision Penning trap for mass determination. Mass values were obtained for the isotopes with mass numbers A=126,129,130,136. They are consistent with previous results except for the case of $^{126}Xe$ where a significant deviation from the literature value was found. …
Trace Analysis of Plutonium and Technetium by Resonance Ionization Mass Spectrometry Using an Atomic Beam and a Laser Ion Source
1990
A method for low level detection of plutonium and technetium is described with a detection limit of less than 107 atoms. Plutonium is a very toxic element due to its radioactive decay as well as its chemical behaviour. It was released to the environment in large amounts during the fifties and sixties of his century, principally by nuclear-weapon tests and some accidents. As a result about 0.4 − 4 mBq per gram 239Pu(T1/2 = 24390 y), corresponding to 4 × 108 − 4 × 109 atoms, can be found in the Northern Hemisphere in soil samples.