Search results for "Thermography"
showing 10 items of 146 documents
Can exercise-induced muscle damage be related to changes in skin temperature?
2018
Measurement of skin temperature using infrared thermography has become popular in sports, and has been proposed as an indicator of exercise-induced muscle damage after exercise. However, the relationship between skin temperature and exercise-induced muscle damage is still unclear. Here we set out to investigate the relationship between skin temperature and exercise-induced muscle damage.Twenty untrained participants completed a protocol of exercise for calf muscles. Before and after exercise blood samples were collected to determine creatine kinase and acetylcholinesterase activity. Thermal images were recorded from the exercised muscles to determine skin temperature. Delayed onset muscle s…
Infrared Thermography assisted evaluation of static and fatigue Mode II fracture toughness in FRP composites
2019
Abstract The work proposes the combined use of a Modified Transverse Crack Tension (MTCT) test coupon and Infrared Thermography, to evaluate the static and fatigue behaviour of Fibre Reinforced Polymer composites under Mode II delamination. Artificial delaminations starters are added to the TCT coupon, whose effects on the Strain Energy Release Rate are discussed. Infrared Thermography and Thermoelastic Stress Analysis are implemented to investigate stresses and delaminations growths on two FRP materials: a pre-preg IM7/8552 carbon fibre-epoxy and a glass-fibre reinforced epoxy laminates. The thermographic, thermoelastic and second harmonic signals have been obtained and used to monitor the…
Comparing different processing methods in apple slice drying. Part 1. Performance of microwave, hot air and hybrid methods at constant temperatures
2019
The drying curves, energy efficiency and colour variations of sliced apples dried at various temperatures and using different techniques were evaluated, i.e. microwave (35, 55 and 65 °C), hot air (35, 55, 65 and 75 °C) and combination of both (65 °C). The microwave (MW) tests also included comparison between air recirculation and continuous inlet of fresh air. Each drying method was evaluated at a fixed temperature level by means of a control system based on infrared thermography. The time required to complete the drying process at 65 °C varied from about 44 min for MW with fresh air ventilation (double with air recirculation), to 122 min for hybrid heating and 238 min for hot air. Drying k…
Infrared thermography-based evaluation of the elastic-plastic J-integral to correlate fatigue crack growth data of a stainless steel
2019
Abstract The elastic-plastic J-integral is adopted to correlate fatigue crack growth data of ductile metals. An analytical link is known to exist between the J-integral and the strain energy density averaged in a control volume embracing the crack tip. On the other hand, the strain energy fluctuation is the source of temperature variations close to a fatigue crack tip of a metal material; hence the possibility to measure the J-integral from infrared thermographic scanning at the crack tip is envisaged and it is the focus of this paper. It is proposed that the elastic component of the J-integral is derived from a thermoelastic stress analysis, while the plastic component of the J-integral is…
A numerical and experimental study through laser thermography for defect detection on metal additive manufactured parts
2017
Additive manufacturing has been recently employed in industrial sectors with the fundamental requirement for zero defect parts. Technological developments in additive manufacturing notwithstanding, there continues to be a scarcity of non-destructive inspection techniques to be exploited during the manufacturing process itself, thus limiting industrial advancements and extensive applications. Therefore, being able to integrate the defect inspection phase within the additive manufacturing process would open the way to enabling corrective actions on the component in itinere, that is, before reaching the final product. For this reason, new methods of in-process monitoring are gaining more and m…
A methodology to assess the effect of sweat on infrared thermography data after running: Preliminary study
2020
Abstract The aim of this technical report is to present a preliminary study carried out to define the methodology to be employed for further research on assessing the effect of sweating on infrared thermography and thermal contact sensors after moderate intensity running. Nine recreational runners participated in this preliminary study. Participants ran for 35 min (5 min warm-up and 30 min at a rate of perceived exertion rate of 12 points on the 6–20 points Borg scale). Skin temperature (infrared thermography, Flir E60bx; four thermal contact sensors, IButton DS1923 Hygrochron) and relative humidity (thermal contact sensors) were measured on the anterior thigh on both lower limbs before and…
Application of infrared thermography as a complementary technique to conventional imaging techniques in paediatrics: case studies
2018
The use of infrared thermography has been shown to be useful in several areas. Its applicability in medicine is based on the fact that the skin emits spontaneously and continuously infrared radiati...
Effects of the cycling workload on core and local skin temperatures
2016
[EN] Purpose: The aim of the study was to determine the influence of cycling workload on the variation of core and skin temperature of the different body regions, and the relationship between both temperature variables. Method: Fourteen cyclists performed two 45-min cycling tests at 35% and 50% of peak power output on different days. The cadence was constant in both tests (90 rpm). Core temperature was measured continuously throughout the test and local skin temperature was recorded before, immediately after and 10 min after finishing the cycling test. Differences in variation of the core and skin temperature and in the effort perception and body mass loss due to different cycling workload …
Heat transfer in semi-transparent materials during laser interaction
2004
Abstract A model of energy exchange, based on the finite element method is specially developed to determine the thermal field for semi-transparent polymers irradiated by laser. Our model, which uses the finite element method, allows to define the laser and specific structure characteristics in terms of density of power, speed and shape of the spotlight, material coefficient absorption, etc. The model has been experimentally validated by measuring the thermal response induced by the laser source. The experimental part of the study has been performed using a semiconductor laser diode source and an infrared thermography camera.
Thermal Characterization of Friction Stir Welded Butt Joints
2005
In the paper the thermal characterization of friction stir welding processes (FSW) of aluminium alloys is presented. In particular both embedded thermocouples and a thermography analysis were utilized in order to acquire the temperature vs. time curves in point of interests of the joints and the temperature distributions, respectively. Such kind of results are very important in order to investigate the material conditions during the FSW process.