Thermo-Chromium: A Contactless Optical Molecular Thermometer.
2017
The unparalleled excited-state potential-energy landscape of the chromium(III)-based dye [1]3+ ([Cr(ddpd)2 ]3+ ; ddpd=N,N'-dimethyl-N,N'-dipyridin-2-yl-pyridin-2,6-diamine) enables a strong dual emission in the near infrared region. The temperature dependence of this dual emission allows the use of [1]3+ as an unprecedented molecular ratiometric thermometer in the 210-373 K temperature range in organic and in aqueous media. Incorporation of [1]3+ in biocompatible nanocarriers, such as 100 nm-sized polystyrene nanoparticles and solutol micelles, provides nanodimensional thermometers operating under physiological conditions.
Steam sterilization processes affect the stability of clinical thermometers: Thermistor and prototypal FBG probe comparison
2020
Abstract Temperature is one of the most frequently measured physical quantities in clinical environment and a good biomarker of illness. The need for reusable probes, which have to be sterilized to prevent infections, requires the metrological qualification of thermometer probes in response to ageing effects induced by several sterilization processes. In this study, we investigated the effect of repeated sterilizations on both a commonly-used autoclavable thermistor probe and a prototypal Fiber Bragg Gratings (FBG) probe for temperature measurements. Findings highlighted a greater reliability of the proposed FBG probe than the commercial thermistor. Specifically, the FBG probe was able to w…
Humidity of Anaesthetic Gases with Respect to Low Flow Anaesthesia
1994
It has been demonstrated in an experimental study in swine using the scanning electron microscope that a rebreathing technique utilising minimal fresh gas flowrates significantly improves climatization of anaesthetic gases. Consequently, effects of various anaesthetic techniques on airway climate must be assessed, which covers the need for suitable measuring devices. Basic principles and methods of humidity measurement in flowing anaesthetic gases include gravimetric hygrometry, dew point hygrometry, wet-dry bulb psychrometry, mass spectrometry, spectroscopic hygrometry and electrical hygrometry. A custom-made apparatus for continuous measurement of humidity and temperature in the inspired…
Use of the Distress Thermometer in Cancer Survivors: Convergent Validity and Diagnostic Accuracy in a Spanish Sample
2019
Objectives To explore the performance of the National Comprehensive Cancer Network Distress Thermometer (DT) as a distress screening tool in cancer survivors. Sample & setting 236 Spanish adult-onset cancer survivors who visited the Fundacion Instituto Valenciano de Oncologia in Valencia, Spain, for follow-up appointments. Methods & variables Survivors completed the DT and the Brief Symptom Inventory 18 (BSI-18), which has established a cutoff score for identifying clinically significant distress. Results Receiver operating characteristic curve analysis of the DT scores relative to the BSI-18 cutoff score showed good overall accuracy. For a score of 5 or greater, sensitivity, specificity, p…
Patient reported feasibility and acceptance of Montreal Cognitive Assessment (MoCA) screening pre- and postoperatively in brain tumour patients.
2018
Abstract Background Montreal Cognitive Assessment (MoCA) represents a short screening tool for neuropsychological deficits. The study’s aim was to test feasibility and acceptance of MoCA in patients with brain tumours perioperatively. Methods Patients with supratentorial located brain tumours were assessed preoperatively (t1, day −1) and postoperatively (t2, day 3–5) using EORTC-QLQ-C30 + BN20, Distress Thermometer (DT) and the MoCA test (different versions). Feasibility was evaluated by a feedback form and patients were asked about perceived discomfort, overstraining or complexity of MoCA. Results of MoCA were correlated with clinical factors. Results 63 patients participated, 19 were male…
Patient satisfaction with a rapid diagnosis of suspicious breast lesions: Association with distress and anxiety
2017
Few studies have explored with standard measures patient satisfaction with care at the time of the diagnosis through rapid diagnostic pathways. This study aimed to assess satisfaction levels at the time of the diagnosis in a One-Stop Breast Unit and to examine associations with psychological states. An anonymous cross-sectional survey was conducted at a single center's One-Stop Breast Unit, to assess patient satisfaction regarding several aspects of the Unit. Two days after the diagnosis, 113 participants completed self-reported questionnaires evaluating satisfaction (Out-Patsat35), anxiety (State Anxiety Inventory), and psychological distress (Distress Thermometer). Overall, patients were …
Mean Radiant Temperature Measurements through Small Black Globes under Forced Convection Conditions
2021
One of the most critical variables in the field of thermal comfort measurements is the mean radiant temperature which is typically measured with a standard 150 mm black globe thermometer. This is also the reference instrument required for the assessment of heat stress conditions by means of the well-known Wet Bulb Globe Temperature index (WBGT). However, one of the limitations of this method is represented by the relatively long response time. This is why in recent years there has been a more and more pressing need of smart sensors for controlling Heating Ventilation and Air Conditioning (HVAC) systems, and for pocket heat stress meters (e.g., WBGT meters provided with table tennis balls). …
Particle surface area dependence of mineral dust in immersion freezing mode: investigations with freely suspended drops in an acoustic levitator and …
2014
Abstract. The heterogeneous freezing temperatures of supercooled drops were measured using an acoustic levitator. This technique allows one to freely suspend single drops in the air without any wall contact. Heterogeneous nucleation by two types of illite (illite IMt1 and illite NX) and a montmorillonite sample was investigated in the immersion mode. Drops of 1 mm in radius were monitored by a video camera while cooled down to −28 °C to simulate freezing within the tropospheric temperature range. The surface temperature of the drops was contact-free, determined with an infrared thermometer; the onset of freezing was indicated by a sudden increase of the drop surface temperature. For compari…
Comparison between rectal and body surface temperature in dogs by the calibrated infrared thermometer
2020
Highlights • Dogs poorly tolerate rectal temperature measurements with a contact thermometer. • Existing alternative approaches used uncalibrated infrared thermometers. • Gum and inguinal temperature are correlated moderately to rectal temperature. • Hyperthermia was detected with sensitivity and specificity up to 90.0% and 78.6%. • Future studies should include a calibrated thermometer and control external factors.
Agreement between body surface and rectal temperature in cats
2021
Measuring body temperature in cats is an essential part of every clinical examination. Typically, rectal temperature measurement is conducted, but the procedure is poorly tolerated, and it often triggers stress-related changes in physiological parameters like pulse rate and blood pressure. Therefore, non-contact infrared thermometers have been studied on a few body surface measurement sites. However, existing studies included only commercial thermometers, which do not guarantee the correct temperature readings. In this study, we applied a custom-made and calibrated infrared thermometer for measuring feline body surface temperature on easily-accessible measurement sites of the eye, gum, and …