Search results for "Thermometers"
showing 8 items of 8 documents
DEEP RESERVOIR TEMPERATURES OF LOW-ENTHALPY GEOTHERMAL SYSTEMS IN TUNISIA: NEW CONSTRAINTS FROM CHEMISTRY OF THERMAL WATERS
2012
Tunisia is characterized by hot and warm groundwaters (temperature up to 75 °C) which represent the surface manifestation of geothermal systems hosted in carbonate-evaporite rock sequences. The T-conditions of Tunisia deep thermal reservoirs are here evaluated for the first time at the regional scale. The results here shown clearly highlight the limitations inherent in the application of common geothermometric methods in the estimation of equilibrium temperatures in sedimentary environments. The modeling approach proposed by Chiodini et alii (1995), which makes use of the ratios between dissolved HCO3, SO4 and F, provides the most reliable results, and allows us to derive equilibrium temper…
Analysis of Mercury Pollution in Air in Urban Area of Riga Using Atomic Absorption Spectrometry
2015
Toxicity of mercury and its compounds is well known, and they are considered as substances of heightened concern. Though mercury is to some extent released into the environment by natural processes such as volcanic eruptions, additional releases from anthropogenic sources have increased the environmental exposure and deposition significantly. There are many commonly used items containing mercury, for instance, mercury light bulbs, switches, and mercury thermometers, the disposal of which into trashcans can cause an increase of mercury concentration in the air of the local area. The paper reports mercury pollution surveys performed in several districts of Riga (the capital of Latvia). Using …
Ordering kinetics in synthetic Mg(Al,Fe3+)2O4 spinels: Quantitative elucidation of the whole Al-Mg-Fe partitioning, rate constants, activation energi…
2014
A novel procedure, based on the application of the kinetics simulator Gepasi, has been successfully applied for modeling the cation ordering process in two synthetic Mg(Al2-yFe3+y)O4 spinels (y~ 0.39 and 0.54, samples F39 and F54, respectively). The kinetic profiles suggested a two-stage mechanism, with rapid inter-site exchange of Fe3+ with Mg followed by slow exchange of Al with Mg. The trial to apply the classical approaches, based on the explicit solutions of the differential equations corresponding to single-cation (Sha-Chappel model) or two-cation (Müller model) exchange reactions, proved not feasible in the whole time range, thus implying a lack of information about the exchange proc…
Peltier effect-based temperature challenge: an improved method for diagnosing cold urticaria.
2004
Normal metal - insulator - superconductor thermometers and coolers with titanium-gold bilayer as the normal metal
2018
We have fabricated superconductor - insulator - normal metal - insulator - superconductor (SINIS) tunnel junctions in which Al acts as the superconductor, AlOx is the insulator, and the normal metal consists of a thin Ti layer (5 nm) covered with a thicker Au layer (40 nm). We have characterized the junctions by measuring their current-voltage curves between 60 mK and 750 mK. For comparison, the same measurements have been performed for a SINIS junction pair whose normal metal is Cu. The Ti-Au bilayer decreases the SINIS tunneling resistance by an order of magnitude compared to junctions where Cu is used as normal metal, made with the same oxidation parameters. The Ti-Au devices are much mo…
Control of brain temperature during experimental global ischemia in rats.
1999
Temperature control during experimental ischemia continues to be of major interest. However, if exposure of brain tissue is necessary during the experiment, regional heat loss may occur even when the core temperature is maintained. Furthermore, valid non-invasive brain temperature monitoring is difficult in small rodents. This paper describes a method for both monitoring and maintenance of brain temperature during small animal preparations in a stereotaxic frame. The device used includes an ear-bar thermocouple probe and a small near-infrared radiator. The new equipment permitted to maintain peri-ischemic brain temperature at a desired level while carrying out non-invasive continuous record…
Accuracy and stability of temperature probes for intracranial application.
2004
Intracranial temperature measurement may play a pivotal role for prognosis and treatment of neurological and neurosurgical patients. For reliable clinical application, accurate temperature readings are therefore necessary. We present an independent in vitro study investigating the accuracy and stability of three temperature probes. Eight Neurovent-P Temp (RN), eight Licox temperature sensors (LT) and eight Neurotrend sensors (NT) were placed into a water bath. The temperature was increased in 3 degrees C increments from 30 to 42 degrees C before (accuracy test day 0) and after (accuracy test day 5) a long-term stability test run at 37 +/- 0.2 degrees C. The accuracy tests revealed deviation…
Humidity of Anaesthetic Gases with Respect to Low Flow Anaesthesia
1994
It has been demonstrated in an experimental study in swine using the scanning electron microscope that a rebreathing technique utilising minimal fresh gas flowrates significantly improves climatization of anaesthetic gases. Consequently, effects of various anaesthetic techniques on airway climate must be assessed, which covers the need for suitable measuring devices. Basic principles and methods of humidity measurement in flowing anaesthetic gases include gravimetric hygrometry, dew point hygrometry, wet-dry bulb psychrometry, mass spectrometry, spectroscopic hygrometry and electrical hygrometry. A custom-made apparatus for continuous measurement of humidity and temperature in the inspired…