Search results for "Time Factor"
showing 10 items of 3219 documents
The use of a new kind of low profile retractor for arteriovenous fistula procedure simplifies and speeds up the intervention
2009
Purpose The aim of this study was to demonstrate the effectiveness of a new kind of disposable surgical retractor in arteriovenous fistula (AVF) procedures in order to achieve an easier, faster and safer surgical intervention. Methods Between January and June 2008, 22 AVF procedures were performed using the 3PAWS ReeTrakttrade; (Insightra Inc. - Irvine, Ca., USA) a self-retaining, low profile retractor. An equivalent patient sample, in which an AVF was performed using conventional retraction devices, was considered for comparison of the intra- and post-operative results. Results In all of the 22 AVF procedures performed, the ReeTrakt™ system has simplified the performance of the surgical te…
Chick embryo retina development in vitro: the effect of insulin.
1995
In this paper we study the development of chick embryo retina cultured in vitro and the effects exerted by insulin. Retinas were removed from 7-day embryos and cultured in serum- and hormone-free medium for 7 additional days. Under these conditions retinal cells survived and underwent cholinergic differentiation, as previously ascertained by Hausman et al. (Dev. Brain Res., 1991, 59: 31-37). However, a great retardation of development was noted compared to uncultured control, 14-day retina. In fact both wet weight and DNA and protein content increased much slower than in ovo and the tubulin content decreased below even the starting value. In addition, although after 7 days in culture retina…
Comparison of Percutaneous Coronary Intervention (With Drug-Eluting Stents) Versus Coronary Artery Bypass Grafting in Women With Severe Narrowing of …
2014
Women typically present with coronary artery disease later than men with more unfavorable clinical and anatomic characteristics. It is unknown whether differences exist in women undergoing treatment for unprotected left main coronary artery (ULMCA) disease. Our aim was to evaluate long-term clinical outcomes in women treated with percutaneous coronary intervention (PCI) with drug-eluting stents versus coronary artery bypass grafting (CABG). All consecutive women from the Drug-Eluting stent for LefT main coronary Artery disease registry with ULMCA disease were analyzed. A propensity matching was performed to adjust for baseline differences. In total, 817 women were included: 489 (59.8%) unde…
Coronary stent implantation in acute vessel closure 48 hours after an unsatisfactory coronary angioplasty
1990
We report the implantation of a balloon-expandable stent in a patient with acute vessel closure in the state of evolving myocardial infarction following 48 hr after unsatisfactory coronary angioplasty. The stent was implanted after successful recanalization of an occluded left anterior descending artery, with repeated unsatisfactory results of balloon angioplasty. Adjunct thrombolytic therapy was contraindicated. No residual stenosis was documented in immediate control angiograms, or after 24 hr, 3 weeks, and 4 months.
Transverse Small Skin Incision for Carotid Endarterectomy
2015
The purpose of this report is to determine the feasibility of short transverse skin incision (STI4 cm) for eversion (EEA) and patch (PEA) endarterectomy with or without shunt by comparing it with the outcomes after long transverse skin incision (LTI 4-8 cm).Of 164 elective consecutive patients (71 ± 2.73% symptomatic) operated at one institution over 24 months, 81 were treated with STI, while 83 patients received LTI. The LTI and STI groups did not differ in terms of age, symptoms, or risk factors. EEA or PEA under locoregional (LRA) or general (GA) anesthesia were performed.STI was associated with shorter operation times (75.19 ± 15.33 vs. 94.87 ± 41 and 99.4 ± 27.36 vs. 132.66 ± 51.32, re…
A new thrombectomy catheter device (AngioJet) for the disruption of thrombi: An in vitro study
1999
In this study we examined a new thrombectomy catheter device. Different kinds of in vitro generated thrombi and cadaver thrombi were disrupted in test tubes. The mean disruption rate (and disruption time for 1 g of thrombus) was 225 +/- 65 mg/sec (5 +/- 2 sec) for whole-blood, 117 +/- 60 mg/sec (12 +/- 9 sec) for fibrin, 41 +/- 18 mg/sec (30 +/- 18 sec) for mixed, 70 +/- 42 mg/sec (17 +/- 5 sec) for unorganized, 45 +/- 8 mg/sec (22 +/- 4 sec) for partly, and 5 +/- 1 mg/sec (216 +/- 29 sec) for completely organized cadaver thrombi (P0.05). More than 99% of fragmented particles of whole-blood thrombi were 0-12 microm in diameter. The particle size of fibrin, mixed, and cadaver thrombi was sim…
Influence of cold ischemia time on complement activation, neopterin, and cytokine release in liver transplantation.
2004
The aim of this study was to determine whether a cold ischemia time (CIT) of12 hours influences the activation of complement as well as the plasma concentrations of neopterin, interleukin (IL)-6, or IL-8 in orthotopic liver transplantation (OLT).Eighteen consecutive patients undergoing OLT using a veno-venous bypass technique were divided into 2 groups: duration of CIT12 hours (group 1; n = 11), and CIT12 hours (group 2; n = 7). Blood samples were drawn preoperatively, 1 minute before, and 120 minutes after reperfusion.Preoperatively, complement split products, neopterin, IL-6, and IL-8 levels did not differ between the groups. At 120 minutes after reperfusion, the concentrations of C3a, SC…
A score model for the continuous grading of early allograft dysfunction severity
2014
Early allograft dysfunction (EAD) dramatically influences graft and patient outcomes. A lack of consensus on an EAD definition hinders comparisons of liver transplant outcomes and management of recipients among and within centers. We sought to develop a model for the quantitative assessment of early allograft function [Model for Early Allograft Function Scoring (MEAF)] after transplantation. A retrospective study including 1026 consecutive liver transplants was performed for MEAF score development. Multivariate data analysis was used to select a small number of postoperative variables that adequately describe EAD. Then, the distribution of these variables was mathematically modeled to assig…
Zoledronate, ibandronate and clodronate enhance osteoblast differentiation in a dose dependent manner – A quantitative in vitro gene expression analy…
2010
Bisphosphonates are widely used in the clinical treatment of bone diseases with increased bone resorption. In terms of side effects, they are known to be associated with osteonecrosis of the jaw (BONJ). There are two groups of bisphosphonates: the nitrogen-containing bisphosphonates, e.g. zoledronate and ibandronate, and the non-nitrogen-containing bisphosphonates, e.g. clodronate. Their impact on bone metabolism seems to differ. The objective of this study was to compare the osteogenic differentiation potency of these two pharmacologic groups. Human osteoblasts were stimulated with zoledronate and ibandronate at concentrations of 5×10(-5) M, 5×10(-6) M and 5×10(-7) M over the experimental …
Nonroutine Use of Intra-Aortic Balloon Pump in Cardiogenic Shock Complicating Myocardial Infarction With Successful and Unsuccessful Primary Percutan…
2018
Abstract Objectives The authors sought to compare outcomes of patients with myocardial infarction and cardiogenic shock (CS) treated with percutaneous coronary intervention (PCI) with or without intra-aortic balloon pump (IABP) support according to final epicardial flow in the infarct-related artery. Background A routine use of IABP is contraindicated in patients with myocardial infarction and CS. There are no data regarding the subpopulation of patients who may benefit from such support besides patients with mechanical complications of myocardial infarction. Methods Prospective nationwide registry data of patients with myocardial infarction and CS treated with PCI between 2003 and 2014 wer…