Search results for "Titan"
showing 10 items of 1109 documents
Direct laser welding of pure titanium to austenitic stainless steel
2018
Abstract Direct butt joining of pure titanium to 316L stainless steel with continuous Yb:YAG laser was performed with variation of the beam offset from joint line. Mechanical properties of samples were evaluated by tensile tests and three-point flexural tests. The fractured surfaces and cross sections of welds were examined by scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS) and X-ray diffraction (XRD). Tensile properties of welds were strongly determined by the beam offset from joint line and are well described by Weibull statistics. Ultimate tensile strength of 174 ± 69 MPa and ultimate flexural strength of 297 ± 48 MPa were obtained. Brittle fracture took place in…
Aluminum to titanium laser welding-brazing in V-shaped grooveI
2017
International audience; Laser assisted joining of AA5754 aluminum alloy to T40 titanium with use of Al-Si filler wires was carried out. Continuous Yb:YAG laser beam was shaped into double spot tandem and defocalized to cover larger interaction zone in V shaped groove. Experimental design method was applied to study the influence of operational parameters on the tensile properties of the joints. Microstructure examination and fractography study were carried out to understand the relation between local phase content and fracture mode.Within defined window of operational parameters, statistically important factors that influenced the strength of T40 to AA5754 joints in V groove configuration w…
An in vitro cyclic fatigue resistance comparison of conventional and new generation nickel-titanium rotary files
2018
Background New designs and processing of Niquel-Titanium (NiTi) have been introduced to increase resistance to cyclic fatigue. The purpose of this study was to compare the cyclic fatigue resistance of 3 NiTi rotary instruments, ProTaper Next (PTN; Dentsply Maillefer, Ballaigues, Switzerland), Profile Vortex Blue (PVB; Dentsply Tulsa Dental, Tulsa, OK, USA) and ProTaper Universal (PTU; Dentsply Maillefer, Ballaigues, Switzerland). Material and Methods A cyclic fatigue test was conducted operating instruments from ProTaper Next X2, Profile Vortex Blue 25.06 and ProTaper F2. A total of 234 instruments were rotated in 2 simulated stainless steel curved canals with different angles of curvature …
Implant Abutment Cleaning by Plasma of Argon: 5-Year Follow-Up of a Randomized Controlled Trial.
2015
Contamination of implant abutments could potentially influence the peri-implant tissue inflammatory response. The aim of the present study is to assess the radiographic bone changes around customized, platform-switched abutments placed according to the "one-abutment-one-time" protocol, with and without plasma of argon cleaning treatment.Thirty healthy patients with thin gingival biotype (1 mm) and history of periodontal disease received one maxillary implant each. Immediately before abutment connection, patients were randomly assigned to control group (cleaning protocol by steaming) or test group (plasma of argon treatment). Outcome measures were: 1) success rate of implants and prostheses;…
Time-kill assays of amphotericin B plus anidulafungin against Candida tropicalis biofilms formed on two different biomaterials.
2017
Purpose: To determine the fungicidal activity by time-killing assays of amphotericin B (AMB) combined with anidulafungin (ANF) against biofilms of 2 clinical isolates of Candida tropicalis and the reference strain ATCC® 750, developed on polytetrafluoroethylene (PTFE) and titanium, using the CDC Biofilm Reactor (CBR) as an in vitro model. Methods: Biofilms were developed for 24 hours on the disk surfaces and then exposed to AMB (40 mg/L), ANF (8 mg/L), alone and combined. At predetermined time points after drug exposure, biofilms were removed from the disk surface by vortexing-sonication to quantify viable biofilm cells. Results: Drug activity was dependent on strain and time. After exposur…
2016
Orthopedic implant failure due to aseptic loosening and mechanical instability remains a major problem in total joint replacement. Improving osseointegration at the bone-implant interface may reduce micromotion and loosening. Bone sialoprotein (BSP) has been shown to enhance bone formation when coated onto titanium femoral implants and in rat calvarial defect models. However, the most appropriate method of BSP coating, the necessary level of BSP coating, and the effect of BSP coating on cell behavior remain largely unknown. In this study, BSP was covalently coupled to titanium surfaces via an aminosilane linker (APTES), and its properties were compared to BSP applied to titanium via physiso…
Bioactive potential of silica coatings and its effect on the adhesion of proteins to titanium implants
2018
There is an ever-increasing need to develop dental implants with ideal characteristics to achieve specific and desired biological response in the scope of improve the healing process post-implantation. Following that premise, enhancing and optimizing titanium implants through superficial treatments, like silica sol-gel hybrid coatings, are regarded as a route of future research in this area. These coatings change the physicochemical properties of the implant, ultimately affecting its biological characteristics. Sandblasted acid-etched titanium (SAE-Ti) and a silica hybrid sol-gel coating (35M35G30T) applied onto the Ti substrate were examined. The results of in vitro and in vivo tests and t…
Quantitative and Qualitative in vivo Analysis of Metal Residuals in the Saliva of Subjects with and without Fixed Orthodontic Appliances
2020
Aim of the Work: The aim of this work was to evaluate Ni e Cr ions in the saliva of subjects with and without fixed orthodontic appliances. Materials and Methods: This was a prospective, non-randomized study of 100 patients, so selected: 50 have undergone fixed orthodontic appliance at least from 24 months; others 50 subjects as control-group, without any fixed and/or removable orthodontic appliance It was conducted according to the Declaration of the World Medical Association of Helsinki. The two selected groups were compatible for age, sex, absence of restoration in amalgam or other metals in the oral cavity. The saliva of all the subjects was collected with standardized sterile methods. …
Drugs and diseases: Summary and consensus statements of group 1. The 5th EAO Consensus Conference 2018
2018
OBJECTIVES: The task of this working group was to update the knowledge about the use of drugs and biologicals affecting healing of soft tissue and bone during implant treatment or procedures associated with it. Moreover, the impact of titanium particles and biocorrosion on complications and implant survival has been analysed. MATERIALS AND METHODS: The literature in the areas of interest (platelet concentrates, antiresorptive drugs as well as implant-host interaction) was screened using systematic reviews for the former two areas, whereas a narrative critical review was performed for the latter topic. Two manuscripts on platelet concentrates, one manuscript on antiresorptive drugs and one m…
Accelerating metagenomic read classification on CUDA-enabled GPUs.
2016
Metagenomic sequencing studies are becoming increasingly popular with prominent examples including the sequencing of human microbiomes and diverse environments. A fundamental computational problem in this context is read classification; i.e. the assignment of each read to a taxonomic label. Due to the large number of reads produced by modern high-throughput sequencing technologies and the rapidly increasing number of available reference genomes software tools for fast and accurate metagenomic read classification are urgently needed. We present cuCLARK, a read-level classifier for CUDA-enabled GPUs, based on the fast and accurate classification of metagenomic sequences using reduced k-mers (…