Search results for "Tonometry"
showing 10 items of 67 documents
Intraocular pressure after excimer laser myopic refractive surgery
2001
The aim of this study was to determine whether intraocular pressure (IOP), as measured by Goldmann applanation or non-contact tonometry, shows systematic changes in patients who have undergone photorefractive keratectomy (PRK) or laser in situ keratomileusis (LASIK). IOP was measured by central Goldmann and non-contact tonometry in 54 patients pre and post-PRK, and in 43 patients pre- and post-LASIK. An interval of 12 months was allowed after surgery. Patients were selected to have one of four specific initial values of refractive error (-2.5, -5.0, -7.5 and -10.0 D). Fellow unoperated eyes were used as controls. A paired Student's t-test and a one-way ANOVA test were used for statistical a…
Tolerability of 24-hour intraocular pressure monitoring of a pressure-sensitive contact lens.
2013
Purpose To investigate tolerability and safety of a new diagnostic device for 24-hour intraocular pressure monitoring in healthy subjects and age-matched glaucoma patients. Patients and methods Twenty healthy subjects (group 1) and 20 age-matched glaucoma patients (group 2) were included in this prospective, single-center, open, observational parallel group study. The SENSIMED Triggerfish Sensor is a soft disposable contact lens embedding a telemetry chip and strain gauge sensor for continuous intraocular pressure monitoring. The Sensor was placed in 1 eye for 24 hours. Tolerability was evaluated using a visual analog scale (range, 0 to 100; 0=no discomfort; 100=very severe discomfort). Saf…
Impact of Corneoscleral Contact Lens Usage on Corneal Biomechanical Parameters in Keratoconic Eyes
2019
Objective To analyze the changes in corneal biomechanical parameters of keratoconic eyes with and without intracorneal ring segment (ICRS) implants after 1 year of corneoscleral contact lens (CScL) wear. Methods Seventy-four eyes of 74 patients were divided into three groups: healthy subjects (29 eyes, control group), and 2 groups of subjects with keratoconic eyes (one group of 20 eyes with ICRS implants and one of 25 eyes without them), which were fitted with CScL. Corneal hysteresis (CH), corneal resistance factor (CRF), and corneal-compensated intraocular pressure (IOPcc) were evaluated before fitting CScL and after 1 year of CScL wear. In addition, endothelial cell count (ECC) and centr…
Influence of Refraction on Tonometric Readings After Photorefractive Keratectomy and Laser Assisted In Situ Keratomileusis
2000
PURPOSE To determine the decrease of Goldmann tonometry after photorefractive keratectomy (PRK) and laser assisted in situ keratomileusis (LASIK) according to refraction prior to surgery. METHODS Prospective simultaneous comparative case series of 53 myopic eyes (53 patients) that underwent PRK and 50 (50 patients) that underwent LASIK using the Summit Excimed SVS plus (Summit Technology, Inc., Walthan, MA, U.S.A.). PRK and LASIK were subdivided by refractive error into two subgroups of more than or less than -5 diopters (D). Central tonometric readings were taken prior to surgery and 12 months after surgery. RESULTS In LASIK and PRK subgroups of more than -5 D, 85.7% (24) and 69.6% (24), r…
Long-term Results After Transconjunctival Resuturing of the Scleral Flap in Hypotony Following Trabeculectomy
2013
Purpose To present the 4-year follow-up results in the surgical treatment of hypotony following trabeculectomy with mitomycin C in glaucoma patients with additional flap sutures. Design Retrospective interventional case series. Methods Since 2006, 53 patients with hypotony maculopathy attributable to overfiltration following glaucoma surgery (trabeculectomy with mitomycin C) were included in this institutional study. We were able to follow up intraocular pressure (IOP) and distance-corrected visual acuity in 33 (62%) over 4 years, whereas all were followed over 2 years. To elevate IOP, we placed tangential transconjunctival sutures through the scleral flap and connected them to the adjacent…
Results of an Adaptive Surgical Approach for Managing Late Onset Hypotony After Trabeculectomy With Mitomycin C.
2018
OBJECTIVES The objective of this study is to investigate the results of an adaptive approach of bleb revision surgery for late onset hypotony after trabeculectomy with mitomycin C because of bleb leakage and/or scleral melting. METHODS A total of 29 eyes of 27 patients, aged 63.8±11.7 years with hypotony maculopathy [intraocular pressure (IOP), ≤6 mm Hg] because of late onset bleb leakage and/or scleral melting after trabeculectomy with mitomycin C in which minimally invasive transconjunctival suturing of the scleral flap was impossible were enrolled in this retrospective interventional case series. External bleb leakage was seen in 16 eyes, 11 eyes suffered from scleral melting. Because of…
Flicker Defined Form Perimetry in Glaucoma Suspects with Normal Achromatic Visual Fields
2014
To evaluate if repeated flicker-defined form (FDF) perimetry can detect visual field (VF) defects in glaucoma suspects with normal findings in achromatic standard automated perimetry (SAP).Patients with optic nerve heads (ONHs) or retinal nerve fiber layer (RNFL) findings clinically suspicious for glaucoma and normal SAP were enrolled. Patients underwent VF testing with FDF perimetry (Heidelberg Edge Perimetry, HEP) at two consecutive visits (HEP I and HEP II) and confocal scanning laser ophthalmoscopy with the Heidelberg Retina Tomograph (HRT). Abnormal HEP was defined by cluster-point analysis (CPA) and by the HEP specific glaucoma hemi-field test (GHT). Results were compared with an age-…
Type A Behavior Pattern
2012
Aim : To evaluate the presence of type A behavior in patients affected by open-angle glaucoma (OAG) and the possible role of psychophysiological stress as a risk factor for OAG. Materials and methods Fifty patients, 30 women and 20 men, affected by OAG, underwent ophthalmological examination consisting of complete biomicroscopy, tonometry and daily tonometric curve, examination of the visual field by means of computerized perimeter "Octopus 1-2-3," and its assessment with the Glaucoma Staging System 2, morphologic monitoring of the retinal nerve fiber layer with GDx VCC and psychological assessment (Hamilton Anxiety Rating Scale) to evaluate the presence of anxiety and its level; type A/B p…
Technical note: a comparison of central and peripheral intraocular pressure using rebound tonometry
2007
Purpose: To compare central and peripheral intraocular pressure (IOP) readings obtained with rebound tonometry.Methods: Intraocular pressure was measured on the right eye of 153 patients (65 males, 88 females), aged from 21 to 85 years (mean +/- S.D., 55.5 +/- 15.2 years) with the ICare rebound tonometer at centre, and 2 mm from the limbus (in the nasal and temporal regions along the 0-180O corneal meridian).Results: Intraocular pressure values obtained with the ICare were 14.9 +/- 2.8; 14.1 +/- 2.5 and 14.5 +/- 2.7 mmHg at centre, nasal and temporal corneal locations, respectively. On average, nasal and temporal IOP readings were 0.75 and 0.37 mmHg lower than the central reading (p 0.05, r…
Associations between intracranial pressure, intraocular pressure and mean arterial pressure in patients with traumatic and non-traumatic brain injuri…
2008
Introduction: Anatomical proximity of the eye and the intracranial space is a fact but the existence of physiological and pathophysiological relationships between them is elusive. The objective of this study was to explore anatomical and pathophysiological interactions between the eye and the intracranial space and to assess clinical utility of intraocular pressure measurement in estimation of intracranial pressure in patients with brain injuries and to discover how haemodynamic instability could influence these interactions. Controversy surrounds the recent literature concerning this problem and the consensus has not been achieved. Materials and methods: We evaluated the correlation betwee…