Correlations between central corneal thickness and general anthropometric characteristics and cardiovascular parameters in a large European cohort fr…
2014
PURPOSE The aim of this study was to evaluate the correlations between general anthropometric features and cardiovascular parameters and central corneal thickness (CCT) in an adult European cohort. METHODS Analysis was based on a Gutenberg Health Study cohort that included 5000 subjects (2540 male, 2460 female), aged 35 to 74 years at enrollment. The participants underwent a standardized protocol with a comprehensive questionnaire; ophthalmic examination (slit-lamp biomicroscopy; autorefractometry; noncontact tonometry; fundus photography; CCT measurements (optical pachymetry); visual field testing; and a thorough general examination focused on cardiovascular parameters, psychosomatic evalu…
Subclinical optic neuropathy in Fabry disease.
2009
Fabry disease is a rare X-linked lysosomal storage disorder, caused by the deficiency of alpha-galactosidase A. Ophthalmic features comprise a cornea verticillata, conjunctival aneurysms, tortuous conjunctival and/or retinal vessels, and anterior and posterior subcapsular cataracts. The issue of a possible subclinical optic neuropathy in Fabry disease has been raised recently. In this pilot study, we looked for signs of optic neuropathy in our cohort of Fabry patients.Thirty-one Fabry patients (15 male, 16 female, mean age 34 years) underwent an ophthalmological investigation consisting of assessment of best corrected visual acuity, slit lamp investigation, testing of pupillary reaction, fu…
A European Study of the Performance and Safety of MINIject in Patients With Medically Uncontrolled Open-angle Glaucoma (STAR-II)
2020
Precis In this European study (STAR-II), MINIject, a novel, ab-interno, supraciliary MIGS device, effectively lowered intraocular pressure (IOP) and the need for IOP-lowering medications in patients with primary open-angle glaucoma. Purpose To evaluate the safety and performance of a minimally invasive supraciliary glaucoma drainage device (MINIject DO627, iSTAR Medical SA, Wavre, Belgium) for surgical treatment of primary open angle glaucoma in patients refractory to topical hypotensive medications. Methods In a prospective, interventional, single-arm, multi-center, European study (STAR-II), MINIject was successfully implanted in a standalone procedure in 29 of 31 patients in 8 sites in 3 …
Peripheral corneal thickness and associated factors - results from the population-based German Gutenberg Health Study.
2021
PURPOSE Changes in peripheral corneal thickness are described in various corneal diseases such as corneal ectasia. However, few data exist describing the increase in corneal thickness from central to peripheral and reporting the normal distribution of corneal thickness in rings around the corneal centre. The aim of this study was to report these cornea characteristics and investigate associated factors in a population-based setting. METHODS The Gutenberg Health Study is a prospective, population-based study examining participants in a 5-year follow-up (age range 40-80 years) using Scheimpflug imaging. Corneal thickness was assessed in each participant at the apex, as well as in the corneal …
Femtosecond laser versus mechanical keratome LASIK for myopia.
2005
To assess efficacy, safety, predictability, stability, and changes in corneal higher-order aberrations (CHOAs) and contrast sensitivity (CS) after a femtosecond laser for LASIK and standard LASIK for myopia.Prospective, randomized, comparative clinical study.Two hundred eyes of 100 consecutive patients who underwent LASIK treatment using the VISX S2 laser system. A femtosecond laser for flap creation was used in 100 eyes (50 patients; spherical equivalent [SE], -2.85+/-1.79 diopters [D]), and a mechanical microkeratome was used in 100 eyes (50 patients; SE, -2.90+/-1.63 D).Uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), manifest refraction, CS by means of t…
Central corneal thickness in mucopolysaccharidosis II and VI.
2010
Objective To describe the ultrasonographically detected central corneal thickness (CCT) in patients with Type II and VI mucopolysaccharidosis (MPS) and its impact on applanation tonometry and glaucoma detection. Methods Twenty-eight patients with MPS (19 MPS II, nine MPS VI) underwent pachymetric investigation of CCT. Additionally, ultrasound measurements of axial length of the globe, slit-lamp evaluation with semiquantitative grading of corneal clouding, applanation tonometry, and assessment of refractive error were performed. Results Median average corneal thickness was 534.5 microm (range, 491.5-579.0 microm) in the MPS II and 547.0 microm (range, 492.5-693.05 microm) in the MPS VI group…
A comparison of the Canon TX-20P™ non-contact tonometer and pachymeter in healthy eyes
2012
Background: The aim of this study was to compare the intraocular pressure (IOP) and the central corneal thickness (CCT) measurements obtained with the Canon TX-20P™ with IOP measured with Goldmann applanation tonometer (GAT) and the CCT measured with ultrasound (US) pachymetry in healthy eyes. Methods: Thirty one healthy voluntary subjects participated in the study, age ranging from 16 to 81 years (mean age 50.9 years). In total 58 eyes were selected for analysis. All measurements were performed by the same examiner. The measurements were taken in the same order in all subjects: Canon IOP and CCT, Goldmann IOP and US CCT. Results: A strong correlation was found between IOP for both CCT comp…
Quantitative corneal anatomy: evaluation of the effect of diabetes duration on the endothelial cell density and corneal thickness.
2014
Purpose To evaluate the differences in endothelial cell density (ECD) and central corneal thickness (CCT) between type II diabetic patients and age-matched healthy controls, and determine the impact of time from diagnosis. Methods This is a comparative study of 77 eyes of type II diabetic patients (33 males, 44 females) and 80 eyes of healthy subjects (42 males, and 38 females) whose ages ranged from 38 to 56 years. CCT, ECD, HbA1c levels, and Goldmann tonometry were measured. Results The CCT was significantly higher and the ECD significantly lower in long-term diabetic patients (10 years + since diagnosis) when compared with short-term diabetic patients (<1 year since diagnosis) and contro…
Intraocular pressure measurements during flap preparation using 2 femtosecond lasers and 1 microkeratome in human donor eyes
2012
Purpose To evaluate and compare intraocular pressures (IOPs) during flap preparations performed using 2 femtosecond lasers and a mechanical microkeratome in human donor globes. Setting University Medical Center Mainz, Mainz, and Euroeyes Clinic Stuttgart, Stuttgart, Germany. Design Experimental study. Methods A cannula was inserted through the optic nerve in human globes. The IOP was obtained continuously during flap preparation using the 60 kHz Intralase femtosecond laser, the 200 kHz Visumax femtosecond laser, or the Amadeus II microkeratome. For each experiment, a normal lamellar flap preparation (regular procedure) and a worst-case procedure (femtosecond laser interface was pressed agai…
Tonographic Effect of Ocular Response Analyzer in Comparison to Goldmann Applanation Tonometry.
2016
AIMS The tonographic effect is a phenomenon of intraocular pressure (IOP) reduction following repeated tonometry. This study examines whether the tonographic effect occurs following IOP measurement performed with Ocular Response Analyzer (ORA). METHODS Both eyes of 31 glaucoma patients and 35 healthy controls underwent nine IOP-measurements performed with GAT and ORA. The number of GAT and ORA measurements performed on each eye differed depending on the randomly allocated investigation scheme. Central corneal thickness (CCT), anterior chamber volume (ACV) and anterior chamber depth (ACD) were assessed with Pentacam before and after the repeated GAT/ORA measurements. RESULTS There was no sta…