Search results for "Tooth Apex"

showing 9 items of 19 documents

Morphology of the Physiological Foramen: I. Maxillary and Mandibular Molars

2004

Information concerning the anatomy of the physiological foramen is limited. The aim of this study was to investigate the distance between the physiological and anatomical apex, accessory foramina frequency, and the shape and diameter of the physiological foramen in maxillary and mandibular molars. The apical anatomy of 523 maxillary and 574 mandibular molars from an Egyptian population was investigated by means of a computer-aided stereomicroscope (40 x magnification). The following results were obtained:

MolarPopulationMandibleMandibular first molarMandibular second molarImaging Three-DimensionalTooth Apexstomatognathic systemMaxillaForamenHumansMedicineeducationGeneral DentistryMicroscopyeducation.field_of_studybusiness.industryMandibleAnatomymusculoskeletal systemMolarApex (geometry)MaxillaEgyptDental Pulp CavitybusinessJournal of Endodontics
researchProduct

Influence of Instrument Size on the Accuracy of Different Apex Locators: An In Vitro Study

2008

The aim of this in vitro investigation was to determine the accuracy of 4 different electronic apex locators (EALs) with 3 different instrument sizes. For this study 146 roots were embedded in an agar solution. Electronic measurements were made to the physiologic foramen (apical constriction) with the Elements Apex Locator, Justy II, Raypex 5, and ProPex II and K-type files sizes 08, 10, and 15. Statistical significances were calculated with the sign test (P < .001). Exact measurements to the physiologic foramen were made with the Elements Apex Locator, 36.99%, 39.04%, and 44.93%; Justy II, 38.62%, 32.41%, and 43.41%; Raypex 5, 42.76%, 39.31%, and 39.06%; and ProPex II, 38.62%, 43.45%, and …

OrthodonticsDental InstrumentsAnalytical chemistryApical constrictionEquipment DesignElectronics MedicalApex (geometry)Tooth ApexForamenHumansIn vitro studyGeneral DentistryRoot Canal PreparationMathematicsJournal of Endodontics
researchProduct

Evaluation of Dentaport ZX and Raypex 6 electronic apex locators: an in vivo study

2013

Med Oral Patol Oral Cir Bucal. 2014 Mar 1;19 (2):e202-5. Evaluation of Dentaport ZX and Raypex 6: An in vivo study e202 Journal section: Clinical and Experimental Dentistry Publication Types: Research Evaluation of Dentaport ZX and Raypex 6 electronic apex locators: An in vivo study Saddy Moscoso 1 , Kenneth Pineda 1 , Juan Basilio 1 , Carlos Alvarado 2 , Miguel Roig 2 , Fernando Duran- Sindreu 3 1 MD, Department of Restorative Dentistry and Endodontics, Universitat Internacional de Catalunya, Barcelona, Spain 2 MD, DDS, PhD, Department of Restorative Dentistry and Endodontics, Universitat Internacional de Catalunya, Barcelona, Spain 3 Department of Restorative Dentistry and Endodontics, Un…

OrthodonticsElectronic apex locatorResearchOdontologíaTooth Apex:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludRoot Canal TherapyApex (geometry)Tooth ApexOtorhinolaryngologyClinical and Experimental DentistryUNESCO::CIENCIAS MÉDICASForamenHumansSurgeryGeneral DentistryMathematics
researchProduct

Radiographic Investigation of Frequency and Location of Root Canal Curvatures in Human Mandibular Anterior Incisors In Vitro

2007

The aim of the present in vitro study was to evaluate the degree and location of root canal curvatures of mandibular anterior incisors. A total of 396 extracted human permanent anterior incisors (248 central and 148 lateral) were included in this investigation. Exclusion criteria were teeth with extensive carious lesions, restorations, and root canal treatment. The specimens were fixed in a special device and digitally x-rayed (Heliodent MD; Sirona, Benzheim, Germany; Merlin 2.1, Olympus/PerkinElmer, Waltham, MA) with the parallel technique. The distances from the cementoenamel junction (CEJ) to the first curvatures as well as the according angles were recorded. The results were analyzed de…

OrthodonticsMaterials sciencebusiness.industryRoot canalRadiographyDentistryMandibleRadiography Dental DigitalTooth CervixIncisorstomatognathic diseasesCementoenamel junctionmedicine.anatomical_structureTooth Apexstomatognathic systemotorhinolaryngologic diseasesmedicineHumansOdontometryIn vitro studyDental Pulp CavitybusinessGeneral DentistryJournal of Endodontics
researchProduct

The accuracy of the Raypex5 electronic apex locator using stainless-steel hand K-file versus nickel-titanium rotary Mtwo file

2009

Objectives: Today many clinicians use both stainless-steel hand K-files and nickel- titanium rotary files during endodontic treatment. It is of great importance for the clinician to have confidence in the accuracy of an apex locator even if these files were used interchangeably. The purpose of this in-vitro study was to evaluate the accuracy of the Raypex5 electronic apex locator using stainless-steel hand K-file versus nickel-titanium rotary Mtwo file. Study design: Twenty straight and single canals of maxillary central teeth were used. Access cavities were prepared; actual working length were determined and compared with electronic working length obtained by means of apex locator Raypex5 …

OrthodonticsTitaniumElectronic apex locatorComputer scienceSignificant differencefungitechnology industry and agricultureReproducibility of ResultsIn Vitro Techniques:CIENCIAS MÉDICAS [UNESCO]Stainless SteelRoot Canal TherapyOtorhinolaryngologyTooth ApexNickel titaniumNickelUNESCO::CIENCIAS MÉDICASHumansSurgeryGeneral Dentistry
researchProduct

In vitro comparison of root-canal measurements with conventional and digital radiology.

2002

Aim The present study compared the efficacy of digital and conventional radiology for root-canal length measurement. Methodology Seventy extracted teeth with pre-served roots were used. Root-canal length measurements were completed with K-Flexofiles (numbers 08, 10 and 15) with conventional and digital radiography using two systems (radiovisiography and photostimulate storage phosphor). All films and sensors were exposed at projections of 0 degrees and 20 degrees to the mesial. The images obtained were evaluated with and without magnification, and analysed using the Cohen's kappa test. The accuracy of the three systems to determine the root-canal length were evaluated by measuring the dista…

Orthodonticsbusiness.industryRadiographyRoot canalX-Ray FilmMagnificationRadiography Dental DigitalLength measurementmedicine.anatomical_structureDigital radiologyTooth ApexStorage phosphormedicineRadiography DentalHumansOdontometryDental Pulp CavityProjection (set theory)businessGeneral DentistryDigital radiographyBiomedical engineeringMathematicsInternational endodontic journal
researchProduct

The Evaluation of Four Electronic Apex Locators in Teeth with Simulated Horizontal Oblique Root Fractures

2008

The accuracy of four electronic apex locators (EALs) to locate the apical limit in teeth with simulated horizontal oblique root fractures was investigated. A horizontal oblique incomplete root fracture was simulated on 20 freshly extracted maxillary anterior teeth by means of a notch made on the vestibular root plane 8 mm from the anatomic apex. The EALs investigated were the ProPex (Dentsply Maillefer, Ballaigues, Switzerland), the NovApex (Forum Technologies, Rishon Le-Zion, Israel), the Root ZX (J. Morita Corp, Kyoto, Japan), and the Elements Apex Locator (SybronEndo, Orange CA). The electronic measurements were compared with the real "working length." The accuracy obtained was of 80% (n…

Root planebusiness.industryOblique caseDentistryEquipment DesignMaterials testingTooth ApexElectronics MedicalTooth FracturesTooth rootTooth ApexMaterials TestingHumansOdontometryTooth RootbusinessGeneral DentistryRoot Canal PreparationAnterior teethMathematicsJournal of Endodontics
researchProduct

[The effect of instrumentation on original apical foramen shape using steel vs niti rotatory: computerized analysis]

2002

BACKGROUND. A fundamental requirement to obtain a correct endodontic preparation depends on the respect, during cleaning and shaping, of the original morphology of the apical foramen, (AF), so that the filling material will form a complete seal. METHODS. In our previous studies, in order to verify if this presumption was respected using rotary NiTi instruments with cutting tip, we instrumented extracted teeth characterised by a different degree of root curvatures. Using a standardized system to replace the sample, the original shape of the apical foramen of each tooth was recorded using a computerised technique and then compared to the shape after instrumentation. The data showed difference…

TitaniumTooth ApexSettore MED/28 - Malattie OdontostomatologicheNickelImage Interpretation Computer-AssistedHumansStainless Steelrotary NiTi instruments stainless steel instruments apical foramen shapeRoot Canal PreparationDental Alloys
researchProduct

Haemostatic agents in apical surgery. A systematic review.

2015

Background Blood presence in apical surgery can prevent the correct vision of the surgical field, change the physical properties of filling materials and reduce their sealing ability. Objetive To describe which are the most effective and safest haemostatic agents to control bleeding in patients undergoing apical surgery. Material and Methods TWe carried out a systematic review, using Medline and Cochrane Library databases, of human clinical studies published in the last 10 years. Results The agents that proved more effective in bleeding control were calcium sulphate (100%) and collagen plus epinephrine (92.9%) followed by ferric sulphate (60%), gauze packing (30%) and collagen (16.7%). When…

medicine.medical_specialtyMEDLINEReviewHemostatics03 medical and health sciences0302 clinical medicineTooth ApexApical surgeryHumansMedicineGeneral Dentistrybusiness.industryfood and beverages030206 dentistry:CIENCIAS MÉDICAS [UNESCO]BandagesOral HemorrhageSurgeryOtorhinolaryngologyFilling materialsUNESCO::CIENCIAS MÉDICASSurgerysense organsOral Surgerybusiness030217 neurology & neurosurgery
researchProduct