Search results for "Topic"

showing 10 items of 2844 documents

Imaging modalities and treatment of paediatric upper tract urolithiasis: A systematic review and update on behalf of the EAU urolithiasis guidelines …

2020

Prompt diagnosis and treatment of paediatric urolithiasis are required to avoid long term sequelae of renal damage.To systematically review the literature regarding the diagnostic imaging modalities and treatment approaches for paediatric urolithiasis.PubMed, Science Direct, Scopus and Web of Science were systematically searched from January 1980-January 2019. 76 full-text articles were included.Ultrasound and Kidney-Ureter-Bladder radiography are the baseline diagnostic examinations. Non-contrast Computed Tomography (CT) is the second line choice with high sensitivity (97-100%) and specificity (96-100%). Magnetic Resonance Urography accounts only for 2% of pediatric stone imaging studies. …

medicine.medical_specialtyUreteral CalculiUrologyRadiography030232 urology & nephrologyAsymptomatic03 medical and health sciencesKidney Calculi0302 clinical medicineUrolithiasis030225 pediatricsLithotripsyMedical imagingUreteroscopyMedicineHumansChildModalitiesmedicine.diagnostic_testbusiness.industryUltrasoundMagnetic resonance imagingTreatment OutcomeUpper tractPediatrics Perinatology and Child HealthPractice Guidelines as TopicRadiologymedicine.symptombusinessPyelogramJournal of pediatric urology
researchProduct

Continent diversion with the Mainz pouch.

1996

From 1983 until July 1994, 561 patients in 2 urology departments (Mainz and Wuppertal) underwent a Mainz pouch 1 procedure. The Mainz pouch 1 was used for bladder augmentation in 60 patients, for orthotopic bladder substitution in 61 patients, and for continent cutaneous urinary diversion in 440 patients. In the group of continent cutaneous urinary diversion, the continence mechanism applied was an ileal intussusception nipple in 270 patients, an appendix stoma in 146 patients, a submucosal seromuscular bowel-flap tube in 14 patients, and a submucosal full-thickness bowel-flap tube in 10 patients. Indications for urinary diversion were bladder cancer in 339 patients, anatomical or functiona…

medicine.medical_specialtyUrologyUrinary systemmedicine.medical_treatmentUrinary LeakagePostoperative ComplicationsIleumRisk FactorsmedicineHumansCecumBladder cancerbusiness.industryUrinary retentionUrinary diversionUrinary Reservoirs Continentmedicine.diseasePrognosisAppendixSurgerySurvival Ratemedicine.anatomical_structureBladder augmentationEvaluation Studies as TopicPouchmedicine.symptombusinessFollow-Up StudiesWorld journal of urology
researchProduct

First meta-analysis of octreotide for variceal bleeding. A lost opportunity

2002

medicine.medical_specialtyVariceal bleedingHepatologybusiness.industryOctreotideEsophageal and Gastric VaricesOctreotideGastroenterologyHemostaticsMeta-Analysis as TopicInternal medicineMeta-analysismedicineHumansGastrointestinal Hemorrhagebusinessmedicine.drugJournal of Hepatology
researchProduct

Reperfusion of liver graft during transplantation: techniques used in transplant centres within Eurotransplant and meta-analysis of the literature

2013

Abstract: It remains unclear which liver graft reperfusion technique leads to the best outcome following transplantation. An online survey was sent to all transplant centres (n=37) within Eurotransplant (ET) to collect information on their technique used for reperfusion of liver grafts. Furthermore, a systematic review of all literature was performed and a meta-analysis was conducted based on patients' mortality, number of retransplantations and incidence of biliary complications, depending on the technique used. Of the 28 evaluated centres, 11 (39%) reported performing simultaneous reperfusion (SIMR), 13 (46%) perform initial portal vein reperfusion (IPR), 1 (4%) performs an initial hepati…

medicine.medical_specialtyVena cavamedicine.medical_treatmentPortal veinMedizin030230 surgeryRevascularizationVenovenous bypassretrograde reperfusionlaw.invention03 medical and health sciences0302 clinical medicineHepatic ArteryRandomized controlled triallawSurveys and QuestionnairesMedicineHumansRandomized Controlled Trials as TopicTransplantationbusiness.industryPortal Veinsimultaneous reperfusion3. Good healthSurgeryLiver TransplantationTransplantationLiver graftEuropeTreatment OutcomeMeta-analysisReperfusion030211 gastroenterology & hepatologyHuman medicineliver reperfusionbusinesssequential reperfusionLiver Circulation
researchProduct

Interocular differences in visual quality due to ocular aberrations and scattering in a patient with post-traumatic anisocoria: A case report

2012

AbstractA 41-year-old patient with visual disturbances after an ocular trauma in right eye three years before was carefully analyzed and discussed. No corneal or intraocular sequelae were present. Only a significant anisocoria could be observed. Right eye (RE) achieved a best spectacle-corrected visual acuity (BSCVA) of 0.05 LogMAR with a refraction of +0.50 sphere and −1.25 cylinder. Left eye (LE) achieved a BSCVA of 0.0 LogMAR with a refraction of +0.75 sphere and −1.00 cylinder. In photopic conditions pupil diameter was 4.96mm for RE and 3.02mm for LE whereas in scotopic conditions, these values were 7.45mm and 6.71mm, respectively. More significant levels of higher-order corneal and ocu…

medicine.medical_specialtyVisual acuitygenetic structuresCase ReportPupilScatteringlcsh:OphthalmologyOphthalmologymedicinelcsh:QC350-467AberraciónScotopic visionPupilaAnisocoriabusiness.industryFunción de dispersión del puntoPupil sizePupilRefractionAnisocoriaPoint spread functioneye diseasesDispersiónlcsh:RE1-994Visual DisturbanceOptometrysense organsmedicine.symptombusinessAberrationlcsh:Optics. LightPhotopic visionOptometryJournal of Optometry
researchProduct

Impact of the pupil size – central optical zone diameter relationship on visual performance in aspheric multifocal contact lenses

2020

Abstract Purpose To determine the impact of different central optical zone diameters (COZDs), obtained from pupil size, on the visual performance of presbyopic subjects fitted with centre-distance simultaneous-image multifocal contact lenses (SIMCLs). Methods Thirty-two presbyopic volunteers, between 45–58 years of age, participated in this prospective, controlled, double-blind study. Subjects were fitted with 5 centre-distance SIMCLs of variable COZD, determined from the measurement of pupil size under photopic light conditions and corresponding to 60, 70, 80, 90 and 100 % of pupil diameter. Subjects visual performance was evaluated through the measurement of distance, intermediate and nea…

medicine.medical_specialtyVisual acuitygenetic structuresContact Lensesmedia_common.quotation_subjectVisual AcuityPupil diameterNear visual acuityCycles per degreeContrast SensitivityDouble-Blind MethodOphthalmologymedicineHumansContrast (vision)Prospective Studiesmedia_commonMathematicsPupil sizePupilGeneral MedicineMiddle Agedeye diseasesOphthalmologySpatial frequencymedicine.symptomOptometryPhotopic visionContact Lens and Anterior Eye
researchProduct

Effect of Varying Levels of Glare on Contrast Sensitivity Measurements of Young Healthy Individuals Under Photopic and Mesopic Vision

2018

Contrast sensitivity (CS), the ability to detect small spatial changes of luminance, is a fundamental aspect of vision. However, while visual acuity is commonly measured in eye clinics, CS is often not assessed. At issue is that tests of CS are not highly standardized in the field and that, in many cases, optotypes used are not sensitive enough to measure graduations of performance and visual abilities within the normal range. Here, in order to develop more sensitive measures of CS, we examined how CS is affected by different combinations of glare and ambient lighting in young healthy participants. We found that low levels of glare have a relatively small impact on vision under both photopi…

medicine.medical_specialtyVisual acuitygenetic structuresEcological validityMesopic visionmedia_common.quotation_subjectcontrast sensitivity functionlcsh:BF1-990AudiologyEyeLuminanceVisual processing03 medical and health sciences0302 clinical medicineglare effectClinical ResearchmedicineContrast (vision)PsychologyEye Disease and Disorders of VisionGeneral Psychologymedia_commonOriginal Researchvisual function measurementNeurosciencesGlare (vision)mesopic visioneye diseasesphotopic visionlcsh:Psychology030221 ophthalmology & optometryCognitive Sciencesmedicine.symptomPsychology030217 neurology & neurosurgeryPhotopic visionFrontiers in Psychology
researchProduct

The Impact on Vision of Aspheric to Spherical Monofocal Intraocular Lenses in Cataract Surgery

2013

Purpose To provide a summary of the impact on vision of an aspheric intraocular lens (IOL) compared with a spherical IOL in cataract surgery. Design Systematic review with meta-analysis. Participants Patients from published randomized controlled trials (RCTs) of cataract surgery with aspheric compared with spherical monofocal IOL implantation. Methods We systematically searched the peer-reviewed literature in MEDLINE, EMBASE, Web of Science, BIOSIS, and the Cochrane Library according to the Cochrane Collaboration method to identify relevant RCTs. The inclusion criteria were RCTs on cataract surgery comparing the use of aspheric versus spherical IOL implantation that assessed visual acuity, …

medicine.medical_specialtyVisual acuitygenetic structuresbusiness.industryMesopic visionmedia_common.quotation_subjectmedicine.medical_treatmentIntraocular lensCochrane LibraryCataract surgeryeye diseasesOphthalmologyMeta-analysisOphthalmologyContrast (vision)MedicineOptometrysense organsmedicine.symptombusinessmedia_commonPhotopic visionOphthalmology
researchProduct

Antivitamin K Drugs in Stroke Prevention

2014

Among the different subtypes of ischaemic strokes, almost 20 % are of cardiac origin. Different are the causes of cardioembolic stroke, but the most common is the atrial fibrillation, a supraventricular arrhythmia. Appropriate use of antiplatelet drugs and anticoagulants after transient ischaemic attack (TIA) or ischaemic stroke depends on whether the underlying cause is cardioembolic or of presumed arterial origin. Adequate antiplatelet therapy is recommended for secondary prevention after cerebral ischaemia of presumed arterial origin, whether for patients with TIA and ischaemic stroke of cardiac origin, mainly due to atrial fibrillation. Vitamin K antagonists (VKAs) are highly effective …

medicine.medical_specialtyVitamin KSettore MED/09 - Medicina InternaAppropriate useInternal medicinemedicineAnimalsHumanscardiovascular diseasesRandomized Controlled Trials as TopicPharmacologySupraventricular arrhythmiabusiness.industryPatient choiceStandard treatmentAnticoagulantsVKAs Stroke preventionAtrial fibrillationmedicine.diseaseStrokeIschemic Attack TransientStroke preventionCardiologyCerebral ischaemiaCardiology and Cardiovascular MedicinebusinessPlatelet Aggregation InhibitorsDiscovery and development of direct thrombin inhibitorsCurrent Vascular Pharmacology
researchProduct

Direct Oral Anticoagulants in the Setting of Catheter Ablation of Atrial Fibrillation: State of art

2021

Atrial fibrillation (AF) represents the arrhythmia of greatest clinical impact and catheter ablation of AF (CAAF) has become the most effective strategy for rhythm control in selected patients. Therefore, appropriate anticoagulation strategies are of paramount importance for patients undergoing CAAF, especially those at high risk, such those with high CHA2DS2VASc scores. Optimal management of anticoagulation before, during, and after CAAF is crucial. Several studies have evaluated the use of different anticoagulation strategies in the periprocedural period. Randomized controlled trial seem to suggest that in patients undergoing CAAF, uninterrupted (or minimally interrupted) direct oral anti…

medicine.medical_specialtyVitamin Kmedicine.medical_treatmentAdministration OralRhythm controlCatheter ablation030204 cardiovascular system & hematologyVitamin klaw.invention03 medical and health sciences0302 clinical medicineRandomized controlled triallawInternal medicineVitamin K/administration & dosagecatheter ablationmedicineHumansrisk factorsIn patientatrial fibrillation030212 general & internal medicineanticoagulationRandomized Controlled Trials as TopicAnticoagulants/administration & dosagebusiness.industryAnticoagulantsAtrial fibrillationGeneral Medicinemedicine.diseaseSettore MED/11 - Malattie Dell'Apparato CardiovascolareOptimal managementTreatment OutcomeState of artCardiologybusinessCardiology and Cardiovascular MedicineAtrial Fibrillation/complications
researchProduct