Search results for "Trachea"
showing 6 items of 186 documents
Diagnostik der trachealen Instabilität: Spiral-CT in Inspiration und Exspiration und respiratorische cine-CT∗
2000
ry Spiral CT and Cine CT. Purpose: In tracheo- and broncho-malacia, localization and determination of collapse is necessary for planning a surgical procedure. We compared inspiratory and spiral CT, cine CT, and bronchoscopy and evaluated the relevance of each method. Methods: Seventeen patients with suspected or verified tracheal stonosis or collapse underwent paired inspiratory and exspiratory spiral CT and cine CT during continuous respiration (temporal increment 100 ms). The tracheal cross-sectional area was calculated and compared. Results : In addition to bronchoscopy, further information concerning localization, extent, collapse, stability of the tracheal wall, distal portions of the …
Evaluation of the McGrath® Series 5 videolaryngoscope after failed direct laryngoscopy*
2010
Summary Unanticipated difficulties during tracheal intubation and failure to intubate are among the leading causes of anaesthesia-related morbidity and mortality. Using the technique of video laryngoscopy, the alignment of the oral and pharyngeal axes to facilitate tracheal intubation is unnecessary. In this study we evaluated the McGrath® Series 5 videolaryngoscope for tracheal intubation in 61 patients who exhibited Cormack and Lehane grade 3 or 4 laryngoscopies with a Macintosh laryngoscope. Using the McGrath resulted in an improved glottic view, compared to Macintosh laryngoscope. Laryngoscopy was improved by one grade in 10%, by two grades in 80% and by three grades in 10% of cases (p …
Effects of indomethacin on muscarinic inhibition of endogenous noradrenaline release from rat isolated trachea
1993
The release of endogenous noradrenaline from rat isolated tracheae was evoked by electrical field stimulation (3 Hz, 540 pulses) in the presence of yohimbine, desipramine and tyrosine. The muscarine receptor agonist oxotremorine concentration-dependently inhibited the evoked release of noradrenaline by 95% at 1 μmol/l, EC50 values in two series of experiments 41 and 57 nmol/l, respectively. The effect of oxotremorine was antagonized by the non-selective muscarine receptor antagonist scopolamine (10–1000 nmol/l) in a manner suggesting a simple competitive interaction (slope of Schild plot −0.94; pA2 value 8.88). However, the M2 selective muscarine receptor antagonist methoctramine (0.1–10 μm…
The ultra-thin bronchoscope in management of the difficult paediatric airway
1987
The use of an ultra-thin flexible fiberoptic bronchoscope with a single lumen diameter of 2.7 mm at the distal tip to assist intubation of paediatric patients with a difficult airway is reported. Two patients (ages 30 months and 18 months) with mandibular hypoplasia and one patient (three months) with the Pierre-Robin syndrome are reported. In each case two fiberoptic bronchoscopes were used. The first allowed introduction of topical local anaesthetic while the second and smaller one was used for tube placement.
Supraglottic airway devices for surfactant treatment: systematic review and meta-analysis
2019
Objective: To compare surfactant administration via supraglottic airway device (SAD) vs. nasal CPAP alone or INSURE. Study design: A systematic search of PubMed, EMBASE, SCOPUS, Cochrane Central Register of Controlled Trials and Clinicaltrials.gov was performed. Articles meeting inclusion criteria (RCT, surfactant administration via SAD, laryngeal mask, I-gel) were assessed Results: Five RCTs were eligible. Surfactant administration via SAD reduced the need for intubation/mechanical ventilation (RR 0.57, 95%CI 0.38–0.85) and short-term oxygen requirements (MD −8.00, 95%CI −11.09 to −4.91) compared to nCPAP alone. Surfactant administration via SAD reduced the need for intubation/mechanical v…
Pressure support ventilation + sigh in acute hypoxemic respiratory failure patients: Study protocol for a pilot randomized controlled trial, the PROT…
2018
Background Adding cyclic short sustained inflations (sigh) to assisted ventilation yields optimizes lung recruitment, decreases heterogeneity and reduces inspiratory effort in patients with acute hypoxemic respiratory failure (AHRF). These findings suggest that adding sigh to pressure support ventilation (PSV) might decrease the risk of lung injury, shorten weaning and improve clinical outcomes. Thus, we conceived a pilot trial to test the feasibility of adding sigh to PSV (the PROTECTION study). Methods PROTECTION is an international randomized controlled trial that will be conducted in 23 intensive care units (ICUs). Patients with AHRF who have been intubated from 24 h to 7 days and under…