Search results for "Tracking"
showing 10 items of 709 documents
Mini-MALTA: Radiation hard pixel designs for small-electrode monolithic CMOS sensors for the High Luminosity LHC
2020
Journal of Instrumentation 15(02), P02005 (2020). doi:10.1088/1748-0221/15/02/P02005
Alignment of the ALICE Inner Tracking System with cosmic-ray tracks
2010
ALICE (A Large Ion Collider Experiment) is the LHC (Large Hadron Collider) experiment devoted to investigating the strongly interacting matter created in nucleus-nucleus collisions at the LHC energies. The ALICE ITS, Inner Tracking System, consists of six cylindrical layers of silicon detectors with three different technologies; in the outward direction: two layers of pixel detectors, two layers each of drift, and strip detectors. The number of parameters to be determined in the spatial alignment of the 2198 sensor modules of the ITS is about 13,000. The target alignment precision is well below 10 micron in some cases (pixels). The sources of alignment information include survey measurement…
Parameterization-based tracking for the P2 experiment
2017
The P2 experiment in Mainz aims to determine the weak mixing angle θW at low momentum transfer by measuring the parity-violating asymmetry of elastic electronproton scattering. In order to achieve the intended precision of Δ(sin2 θW )/sin2 θW = 0:13% within the planned 10 000 hours of running the experiment has to operate at the rate of 1011 detected electrons per second. Although it is not required to measure the kinematic parameters of each individual electron, every attempt is made to achieve the highest possible throughput in the track reconstruction chain.In the present work a parameterization-based track reconstruction method is described. It is a variation of track following, where t…
Cosmic multi-muon events observed in the underground CERN-LEP tunnel with the ALEPH experiment
2003
Multimuon events have been recorded with the ALEPH-detector, located 140 m underground, in parallel with e$^+$e$^-$ data taking. Benefitting from the high spatial and momentum resolution of the ALEPH tracking chambers narrowly spaced muons in high multiplicity bundles could be analysed. The bulk of the data can be successfully described by standard production phenomena. The multiplicity distribution favors, though not with very high significance, a chemical composition which changes from light to heavier elements with increasing energy around the ``knee". The five highest multiplicity events, with up to 150 muons within an area of $\sim$ 8 m$^2$, occur with a frequency which is almost an or…
First Imaging of Coronal Mass Ejections in the Heliosphere Viewed from Outside the Sun – Earth Line
2007
We show for the first time images of solar coronal mass ejections (CMEs) viewed using the Heliospheric Imager (HI) instrument aboard the NASA STEREO spacecraft. The HI instruments are wide-angle imaging systems designed to detect CMEs in the heliosphere, in particular, for the first time, observing the propagation of such events along the Sun – Earth line, that is, those directed towards Earth. At the time of writing the STEREO spacecraft are still close to the Earth and the full advantage of the HI dual-imaging has yet to be realised. However, even these early results show that despite severe technical challenges in their design and implementation, the HI instruments can successfully detec…
The MEGA project
2004
Abstract We describe the development of a new telescope for Medium Energy Gamma-Ray Astronomy (MEGA) for the energy band 0.4–50 MeV. As a successor to COMPTEL and EGRET (low energies), MEGA aims to improve the sensitivity for astronomical sources by at least an order of magnitude. It could thus fill the severe sensitivity gap between scheduled or operating hard-X-ray and high-energy γ-ray missions and open the way for a future Advanced Compton Telescope. MEGA records and images γ-rays by completely tracking Compton and Pair creation events in a stack of double sided Si-strip track detectors surrounded by a pixelated CsI calorimeter. A scaled down prototype has been built and calibrations us…
A large Streamer Chamber muon tracking detector in a high-flux fixed-target application.
1999
Arrays of limited streamer tubes of the Iarocci type were deployed in our experiment at CERN as part of a forward muon detector system with provisions for the beam to pass through the center of each panel in the array. A total of 16 4 m x 4 m panels were assembled with inductive readout strips on both sides of each panel. An active feedback system. was deployed to regulate the high voltage to the streamer tubes to insure a constant efficiency for minimum ionizing particles. The arrays were operated in this environment for over five years of data taking. Streamer tube track-reconstruction efficiencies and tube replacement rates are reported. (C) 1999 Elsevier Science B.V. All rights reserved.
The UA4/2 experiment at the CERN SpS collider
1997
Abstract The UA4/2 experiment performed at CERN to measure the ratio of the real to the imaginary part of the forward elastic scattering amplitude is described. The accent is placed on the improvements with respect to the previous UA4 experiment, especially on the much improved design of the high-β insertion and a high-resolution, highly multiplexed scintillating fiber tracking detector.
Locust: C++ software for simulation of RF detection
2019
The Locust simulation package is a new C++ software tool developed to simulate the measurement of time-varying electromagnetic fields using RF detection techniques. Modularity and flexibility allow for arbitrary input signals, while concurrently supporting tight integration with physics-based simulations as input. External signals driven by the Kassiopeia particle tracking package are discussed, demonstrating conditional feedback between Locust and Kassiopeia during software execution. An application of the simulation to the Project 8 experiment is described. Locust is publicly available at https://github.com/project8/locust_mc.
A/V ratio as predicted by full width at half maximum and by blood vessel tracking in presence of ocular aberrations
2011
Aberrations impact A/V ratio calculated from full width at half maximum. We investigated whether aberrations affect A/V ratio calculated by tracking the vessels. Aberrations changed the A/V ratio. We conclude that aberrations impact A/V ratio.