Search results for "Transducer"
showing 10 items of 173 documents
A Generalization of Girod's Bidirectional Decoding Method to Codes with a Finite Deciphering Delay
2012
Girod’s encoding method has been introduced in order to efficiently decode from both directions messages encoded by using finite prefix codes. In the present paper, we generalize this method to finite codes with a finite deciphering delay. In particular, we show that our decoding algorithm can be realized by a deterministic finite transducer. We also investigate some properties of the underlying unlabeled graph.
Role of JAK/STAT in Interstitial Lung Diseases; Molecular and Cellular Mechanisms
2021
Interstitial lung diseases (ILDs) comprise different fibrotic lung disorders characterized by cellular proliferation, interstitial inflammation, and fibrosis. The JAK/STAT molecular pathway is activated under the interaction of a broad number of profibrotic/pro-inflammatory cytokines, such as IL-6, IL-11, and IL-13, among others, which are increased in different ILDs. Similarly, several growth factors over-expressed in ILDs, such as platelet-derived growth factor (PDGF), transforming growth factor β1 (TGF-β1), and fibroblast growth factor (FGF) activate JAK/STAT by canonical or non-canonical pathways, which indicates a predominant role of JAK/STAT in ILDs. Between the different JAK/STAT iso…
Numerical expressions for the computation of coincidence-summing correction factors in γ-ray spectrometry with HPGe detectors
2009
Numerical expressions to compute gamma-gamma and gamma-X(K) coincidence summing corrections were deduced by using a suitable computer program and a matrix representation of a decay scheme. For point sources only full-energy peak and total efficiencies are needed. Alternatively, values of peak-to-total ratio can be introduced. For extended sources, the same expressions can be considered with the introduction of "effective efficiencies". Examples of the use of the expressions for point sources and a particulate filter sample measured with a 60% relative efficiency HPGe detector are reported.
Electrical transduction in phthalocyanine-based gas sensors: from classical chemiresistors to new functional structures
2009
Phthalocyanines are organic-based materials which have attracted a lot of research in recent times. In the field of sensors, they present interesting and valuable potentialities as sensing elements for real gas sensor applications. In the present article, and taking some of our experiments as representative examples, we review the different ways of transduction applied to such applications. Some of the new tendencies and transducers for gas sensing based on phthalocyanine derivatives are also reported. Among them, electrical transduction (resistors, field-effect transistors, diodes, etc.) has been, historically, the most commonly exploited way for the detection and/or quantification of gas…
SVILUPPO DI UN SISTEMA DI ENERGY HARVESTING DALLA PIOGGIA
2014
Ultra-sensitive refractive index sensor using CMOS plasmonic transducers on silicon photonic interferometric platform
2020
Optical refractive-index sensors exploiting selective co-integration of plasmonics with silicon photonics has emerged as an attractive technology for biosensing applications that can unleash unprecedented performance breakthroughs that reaps the benefits of both technologies. However, towards this direction, a major challenge remains their integration using exclusively CMOS-compatible materials. In this context, herein, we demonstrate, for the first time to our knowledge, a CMOS-compatible plasmo-photonic Mach-Zehnder-interferometer (MZI) based on aluminum and Si3N4 waveguides, exhibiting record-high bulk sensitivity of 4764 nm/RIU with clear potential to scale up the bulk sensitivity value…
Timing performance of the silicon PET insert probe
2010
Simulation indicates that PET image could be improved by upgrading a conventional ring with a probe placed close to the imaged object. In this paper, timing issues related to a PET probe using high-resistivity silicon as a detector material are addressed. The final probe will consist of several (four to eight) 1-mm thick layers of silicon detectors, segmented into 1 x 1 mm(2) pads, each pad equivalent to an independent p + nn+ diode. A proper matching of events in silicon with events of the external ring can be achieved with a good timing resolution. To estimate the timing performance, measurements were performed on a simplified model probe, consisting of a single 1-mm thick detector with 2…
US-Elastography for Breast Lesion Characterization: Prospective Comparison of US BIRADS, Strain Elastography and Shear wave Elastography
2020
To evaluate the diagnostic performance of strain elastography (SE) and 2 D shear wave elastography (SWE) and SE/SWE combination in comparison with conventional multiparametric ultrasound (US) with respect to improving BI-RADS classification results and differentiating benign and malignant breast lesions using a qualitative and quantitative assessment. In this prospective study, 130 histologically proven breast masses were evaluated with baseline US, color Doppler ultrasound (CDUS), SE and SWE (Toshiba Aplio 500 with a 7-15 MHz wide-band linear transducer). Each lesion was classified according to the BIRADS lexicon by evaluating the size, the B-mode and color Doppler features, the SE qualit…
A device to trigger automatically electrical stimulation at different states of in- or expiration on the background of variable lung inflation in the…
1975
A device is described which permits to obtain a signal at the beginning of in- or expiration respectively. This signal may be used to trigger an electrical stimulator. To permit studies at different states of lung inflation the tracheal cannula is connected to a spirometer circuit. To produce constant positive or negative air pressure this bellows-type spirometer is loaded with exchangeable metal weights. The tracheal pressure is recorded by means of a pressure transducer, the output of which is taken as signal. The device allows accurate compensation of the DC-component of the transducer output resulting from spirometer operation at a maintained positive or negative pressure.
Detection of disturbing loads in distorted and/or unbalanced power systems: a technique based on a comparison among nonactive powers
2007
This paper presents an innovative technique for the detection of disturbing loads in distorted power systems. It is a single-point strategy, based on a comparison among different "nonactive" power quantities already proposed in literature, that are measured at the same metering section. In the paper, the results obtained with the application of the proposed technique are compared with those of other techniques for the monitoring of the harmonic pollution, both single-point and multi-point. Moreover, the effectiveness of the strategy is discussed, considering also the errors of the measurement transducers.