Search results for "Transducer"
showing 10 items of 173 documents
Maximum bite force after the replacement of complete dentures.
2001
In complete denture wearers the maximum bite force (MBF) is known to be considerably lower than in dentate people. Low MBF might therefore be an indication of poor denture fit but there is limited evidence on this. Therefore, the aim of the present study was to investigate whether MBF can be improved by the replacement of complete dentures for elderly people. Nine edentulous volunteers, average age 74·2 ± 5·5 years and average denture experience 19·4 ± 19·5 years (1–50 years), had replacement dentures made. Functional impressions were taken after border moulding using zinc oxide eugenol paste. After a rehearsal session, MBF was recorded with the old dentures, and with the new dentures immed…
Evaluation of ultrasound transmission velocity and 3-dimensional radiology in different bone types for dental implantology: a comparative ex vivo stu…
2013
Objective To evaluate ultrasound transmission velocity (UTV) for assessment of mechanical bone quality, an ex vivo comparison of different bone types measured with UTV, 2-dimensional (2D) histomorphometry and with 3-dimensional (3D) radiology (cone-beam computerized tomography [CBCT], computerized microtomography [μCT]) was conducted. Study Design Clinical cortical, cancellous, and mixed bone (each n = 6) was measured via UTV (m/s), CBCT (white pixel/black pixel ratio [WP/BP]), μCT (bone volume/total volume [μBV/TV]), and histomorphometry (bone volume/total volume [hBV/TV]). UTV values were correlated with 2D-histomorphometry and 3D-radiologic results. Results For the cortical, cancellous, …
A useful muscarinic parameter and the differential recording of atrial and ventricular tension in the perfused rabbit heart
1971
1. A simple method of recording right atrial tension from the Langendorff perfused rabbit has been described; it is based on the “transverse” method of recording cardiac contractions described by Beckett (1970). 2. Right atrial and ventricular tensions were recorded by transducers attached to threads stitched into the right atrium and right ventricle, the heart being retained and prevented from rotating by two threads stitched into the intraventricular septum as described by Beckett. 3. Right ventricular diastolic tension was adjusted to 7.5 g. Interference with the atrial record by ventricular systole was overcome by adjustment of diastolic right atrial tension to its optimal value between…
Modeling and Experimental Verification of Ultrasound Transmission in Electro Insulation Oil
2012
A verification study of ultrasound transmission numerical simulation results with experiment results is presented in this paper. The work considers a model of a transformer tank which is filled with electro insulating oil. In the experiment, performed under laboratory conditions, an ultrasound wave is generated by a piezoelectric transducer that is fixed in the centre of the tank and measured by another transducer mounted inside the tank at three distances: 10, 20 and 30 cm from the sound source. The transducer is able to measure and generate acoustic waves in the ultrasound frequency band up to 1 MHz. The simulation considers numerical calculation of acoustic pressure distribution inside t…
On Energy Harvesting Using Piezoelectric Transducer with Two-Port Model Under Force Excitation
2019
Piezoelectric (PE) materials are functional materials that can be used for transforming mechanical stress into electrical energy, that can then be stored and used for powering other devices. In this paper, we provide experimental investigation of PE transducers used for energy harvesting under external force-controlled excitation. The lumped parameter electromechanical model (LPEM) has been assumed and brought into a generalized two-port network notation. Laboratory experiments using a universal test machine (UTM) were performed and used for the parameter identification of the model. The two-port model formulation is validated by comparing results of numerical simulations and experimental d…
Defect characterization in Al welded joints by non-contact Lamb wave technique
2006
Abstract The use of air-coupled sensors to detect flaws in Al welded joints and the advantage of Lamb wave for their characterization has been proved. Ultrasonic waves were generated by a pulsed laser and by contact angle-beam transducer, and received by an air-coupled capacitive transducer. Laser-based configuration was used to quickly locate the defect, whereas the angle-beam contact probe configuration to characterize it thanks to the dispersive behavior of Lamb waves. Guided waves allow inspection of the complete thickness with only one scan, permitting to detect and to size both internal and surface defects; their high flexibility in the measurement is due to the various parameters cha…
Harvesting rainfall energy by means of piezoelectric transducer
2013
In this paper a detailed study on the piezoelectric energy harvesting of rainfall is presented. Different features have been taken into account in order to define the limits in this energy harvesting. Only commercial transducers have been considered: a lead zirconate titanate and polyvinylidene difluoride transducer.
Electromechanical Impedance Method to Assess the Stability of Dental Implants
2017
In this paper we illustrate the application of the electromechanical impedance (EMI) technique, popular in structural health monitoring, to assess the stability of dental implants. The technique consists of bonding a piezoelectric transducer to the element to be monitored. When subjected to an electric field, the transducer induces low to high frequency structural excitations which, in turn, affect the transducer's electrical admittance. As the structural vibrations depend on the mechanical impedance of the host structure (in this case the implant secured to the jaw), the measurement of the PZT's admittance can infer the progress of the osseointegration process. In the study presented in th…
The influence of the temperature of insulation oil on the results of measurements of the acoustic emission signals generated by partial discharges
2005
The subject matter of this paper refers to the improvement of the acoustic emission method (AE) used for evaluation of partial discharges (PDs) generated in paper-oil insulation systems of power appliances. The paper presents the measurement and analysis results of the AE signals generated by partial discharges of the surface type (SPDs). The AE signals were measured on the surface of a transformer tub using a broad-band contact transducer, and then they were subject to a time-frequency analysis. The measurements were taken while heating transformer oil in the range from 30 to 85°C with gradation of every 5°C. For time runs, amplitude and energy density spectra the descriptor values that ch…
Elastic wave propagation in bone in vivo: methodology.
1995
The purpose of this study was to investigate the usefulness of elastic wave propagation (EWP) in estimating the mechanical properties (elasticity) of human tibia. The test group was composed of 78-yr-old women assigned to high (n = 19) and low (n = 17) bone mineral density (BMD) groups as measured at the calcaneus by the 125I-photon absorption method. The EWP apparatus consisted of an impact-producing hammer with a force strain gauge and two accelerometers positioned on the bone. Results for nylon and acrylic were used to calibrate the apparatus. Polyvinyl chloride (PVC) solid rods and tubes of various diameters were used to evaluate the relationship between the elastic wave velocity and cr…