Search results for "Transducers"
showing 5 items of 65 documents
Current transformers effects on the measurement of harmonic active power in LV and MV networks
2011
The harmonic active power is used to determine the location of polluting loads, the direction of harmonic power flow and to estimate how consequential a certain current harmonic source is. The highest uncertainties, when measuring harmonic active power, are introduced by the current and voltage transducers. This paper presents experimental results which show the impact of current transformers (CTs) on the accuracy of the harmonic power measurements. An expression for the evaluation of the power error in distorted conditions was developed which can be easily utilized in the case of linear current transducers. It is shown how CTs cannot be considered linear transducers and how the higher the …
A nonlinear biomechanical model for evaluation of cerebrospinal fluid shunt systems.
1994
In view of complications arising from physical properties of cerebrospinal fluid shunts, a biomechanical model of hydrocephalus was set up to study in vivo parameters that may influence their function. These include: intracranial pressure, compliance and pulses, intrathoracic, intra-abdominal, and subcutaneous pressures, and the effects of siphonage and repeated valve flushing. Each of these factors was studied separately upon shunt implantation in the model. Results of testing of a sample low-pressure valve with antisiphon device conformed with consumer information in regard to valve opening pressure and pressure flow measurements. No customer information, however, was supplied concerning …
The influence of lateral release on patello-femoral joint loading in knee arthroplasty
1992
Eight fresh, cadaveric knees have been fitted with four different total knee cemented prostheses. Loading forces at the bone implant fixation interface of the patella component have been measured in a knee joint testing rig by four miniaturized force transducers, before and after a lateral release of the patellar retinaculum. The lateral release resulted in a significant local force reduction in the lateral and/or proximal quadrant of the patella resection plane depending on the knee flexion angle, quadriceps tensile force direction, and the patellar prosthesis design.
Grand Challenges in Acoustic Remote Sensing: Discoveries to Support a Better Understanding of Our Changing Planet
2022
High-Frequency and Ultra-High Frequency Ultrasound: Musculoskeletal Imaging up to 70 MHz
2020
AbstractMusculoskeletal (MSK) ultrasound has well-established advantages, able to investigate very small structures with high resolution and a quick and real-time dynamic evaluation with the possibility of contralateral comparison. Thus ultrasound has kept its own almost exclusive fields of application in daily clinical practice, and it is considered the first-level imaging technique to assess tendons, bursae, and capsuloligamentous structures of small peripheral joints as well as peripheral nerves. Up to now, however, clinical MSK ultrasound imaging could not go beyond the first 1 to 2 cm under the skin, using high-frequency probes up to 18 to 20 MHz with spatial resolution just below mill…