Search results for "Transducers"

showing 5 items of 65 documents

Current transformers effects on the measurement of harmonic active power in LV and MV networks

2011

The harmonic active power is used to determine the location of polluting loads, the direction of harmonic power flow and to estimate how consequential a certain current harmonic source is. The highest uncertainties, when measuring harmonic active power, are introduced by the current and voltage transducers. This paper presents experimental results which show the impact of current transformers (CTs) on the accuracy of the harmonic power measurements. An expression for the evaluation of the power error in distorted conditions was developed which can be easily utilized in the case of linear current transducers. It is shown how CTs cannot be considered linear transducers and how the higher the …

instrument transformersEngineeringVoltage and current harmonicsSwitched-mode power supplyAcousticsActive powerTransducersEnergy Engineering and Power TechnologyLinear currentsPower factorHarmonic powerLinear transducersPower errorsPower transformersVoltage transducersHarmonic analysisHarmonic analysisMaximum valuesCurrent transformerElectrical and Electronic EngineeringPower measurementPhase anglesAbsolute valuesHarmonic power flowTotal harmonic distortionbusiness.industryElectric power distributionCurrent harmonicsElectrical engineeringAC powerCurrent transformerMV networksHarmonicsAccuracy classElectric instrument transformersHarmonicPower system harmonicsCurrent transformers (CTs) instrument transformerspower measurement power system harmonics.businessSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

A nonlinear biomechanical model for evaluation of cerebrospinal fluid shunt systems.

1994

In view of complications arising from physical properties of cerebrospinal fluid shunts, a biomechanical model of hydrocephalus was set up to study in vivo parameters that may influence their function. These include: intracranial pressure, compliance and pulses, intrathoracic, intra-abdominal, and subcutaneous pressures, and the effects of siphonage and repeated valve flushing. Each of these factors was studied separately upon shunt implantation in the model. Results of testing of a sample low-pressure valve with antisiphon device conformed with consumer information in regard to valve opening pressure and pressure flow measurements. No customer information, however, was supplied concerning …

medicine.medical_specialtyIntracranial PressureModels NeurologicalCranial SinusesCerebrospinal fluidCerebrospinal Fluid PressuremedicineTransducers PressureHumansIntracranial pressurebusiness.industryGeneral MedicineEquipment Designmedicine.diseaseCerebral VeinsCerebrospinal Fluid ShuntsSurgeryHydrocephalusCerebrospinal fluid shuntBiomechanical PhenomenaCompliance (physiology)Pediatrics Perinatology and Child HealthFlushingBiomechanical modelEquipment FailureNeurology (clinical)medicine.symptomJugular VeinsbusinessShunt (electrical)Biomedical engineeringHydrocephalusChild's nervous system : ChNS : official journal of the International Society for Pediatric Neurosurgery
researchProduct

The influence of lateral release on patello-femoral joint loading in knee arthroplasty

1992

Eight fresh, cadaveric knees have been fitted with four different total knee cemented prostheses. Loading forces at the bone implant fixation interface of the patella component have been measured in a knee joint testing rig by four miniaturized force transducers, before and after a lateral release of the patellar retinaculum. The lateral release resulted in a significant local force reduction in the lateral and/or proximal quadrant of the patella resection plane depending on the knee flexion angle, quadriceps tensile force direction, and the patellar prosthesis design.

musculoskeletal diseasesKnee Jointmedicine.medical_treatmentTransducersIn Vitro TechniquesKnee JointProsthesis DesignProsthesisWeight-BearingCadaverHumansMedicineOrthopedics and Sports MedicineFixation (histology)OrthodonticsLateral releasebusiness.industryPatellamusculoskeletal systemArthroplastyLigaments ArticularSurgeryPatellaKnee ProsthesisbusinessCadaveric spasmhuman activitiesInternational Orthopaedics
researchProduct

Grand Challenges in Acoustic Remote Sensing: Discoveries to Support a Better Understanding of Our Changing Planet

2022

soundQC801-809Meteorology. ClimatologyGeophysics. Cosmic physicstransducersQC851-999acousticssonarsoundscapessensorsFrontiers in Remote Sensing
researchProduct

High-Frequency and Ultra-High Frequency Ultrasound: Musculoskeletal Imaging up to 70 MHz

2020

AbstractMusculoskeletal (MSK) ultrasound has well-established advantages, able to investigate very small structures with high resolution and a quick and real-time dynamic evaluation with the possibility of contralateral comparison. Thus ultrasound has kept its own almost exclusive fields of application in daily clinical practice, and it is considered the first-level imaging technique to assess tendons, bursae, and capsuloligamentous structures of small peripheral joints as well as peripheral nerves. Up to now, however, clinical MSK ultrasound imaging could not go beyond the first 1 to 2 cm under the skin, using high-frequency probes up to 18 to 20 MHz with spatial resolution just below mill…

tendonTransducersHigh resolutionSkin Diseases030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineTendon InjuriesMedicineHumansRadiology Nuclear Medicine and imagingOrthopedics and Sports MedicineMusculoskeletal DiseasescartilageImage resolutionMusculoskeletal System030203 arthritis & rheumatologyMusculoskeletal imagingbusiness.industryUltrasoundPeripheral Nervous System DiseasesultrasonographyClinical Practicecartilage; peripheral nerve; tendon; ultra-high frequency ultrasonography; ultrasonographyUltra high frequencyultra-high frequency ultrasonographyperipheral nerveUltrasound imagingImaging techniquebusinessBiomedical engineering
researchProduct